Commissioning of the New Online-Radiation-Monitoring-System at the New European XFEL Injector with First Tests of the High-Sensitivity-Mode for Intra-Tunnel Rack Surveillance

Abstract

System, developed for the 17.5 GeV superconducting European XFEL (E-XFEL) that is currently being built between the DESY campus at Hamburg and Schenefeld at Schleswig-Holstein [1,2], has been commissioned in a first system test setup at the E-XFEL Injector. As most of the electronic systems for machine control, diagnostics and safety of the E-XFEL will be located in cabinets inside the accelerator tunnel, the test setup incorporates all system parts like cabinet-internal and -external monitor electronics, infrastructure interface boards, firmware, software, cabling and sensors. Hence the commissioning system setup gives the possibility for first operation of the complete online radiation monitoring system under realistic environmental conditions in terms of irradiation, electro-magnetic interference (EMI) inside the injector tunnel, as well as operational and control system aspects. Commissioning results and measurements based on different internal and external sensor channels will be presented here, together with recent measurements done at different radiation sources using the high-sensibility mode for intra-rack radiation monitoring

    Similar works

    Full text

    thumbnail-image

    Available Versions