Argonne National Laboratory Reports

Abstract

Motion-dependent fluid forces acting on a tube row with a pitch-to-diameter ratio of 1.35 are measured for several flow velocities and a series of oscillation frequencies. Fluid-damping and fluid-stiffness coefficients are obtained from motion-dependent fluid forces as a function of reduced flow velocity. Fluid-force coefficients agree reasonably with published data. Based on the fluid-force coefficients, the critical flow velocity and instability characteristics of tube arrays in crossflow can be predicted

    Similar works

    Full text

    thumbnail-image