Scaling Issues for the Experimental Characterization of Reactor Coolant System in Integral Test Facilities and Role of System Code as Extrapolation Tool
The phenomenological analyses and thermal hydraulic characterization of a nuclear reactor are the basis
for its design and safety evaluation. In light of the impossibility and huge cost of performing meaningful
experiments at full scale, scaled down experimental tests - Integral Effect Test (IET) and Separate Effect
Test (SET) - are more feasible in developing “assessment database”. The data are useful in characterizing
the prototype design and in the validation of computational tools for safety analysis.
The analyses of system behaviors including component interactions in the Reactor Coolant System (RCS),
the Containment System (PCV) and the RCS/PCV coupled system have been extensively investigated
using IETs in the past decades. Though several scaling methods, e.g. Linear, Power/Volume, Three level
scaling, H2TS..., have been developed and applied in the IET and SET design, a direct extrapolation of
the data to the prototype, i.e. the scalability, is in general not possible due to unavoidable scaling
distortions. The scaling distortions are related to many factors, mainly the complex geometry, multiple
component interactions and two phase thermal hydraulic phenomena in steady state and transient
condition of a nuclear reactor. The complex nature of scaling a nuclear reactor requires a large number of
scaling parameters to be simultaneously fulfilled. In addition, physical construction and funding
constraints demand that a scaling compromise is inevitable. Therefore a scaling approach, e.g. time
preserved/not preserved, full height/reduced height, full pressure/reduced pressure, full power/reduced
power…, has to be adopted in accordance with the objective of the IET or SET. Together with the scaling
analysis, Best Estimate (BE) thermal hydraulic system code has been used for supporting experiment
activity (design facilities, interpretation of results, etc) and for extrapolating results to full scale prototype
conditions. Since the closure laws in the system code are mainly based on scaled test data, the
extrapolation of code results remains a challenging and open issue.
Starting from a brief analysis of the main characteristics of IETs and SETFs, the main objective of this
paper is to analyze some IET scaling approaches used to the simulation of RCS responses which
characterize the main scaling limits. The scaling approaches and their constraints in ROSA-III, FIST and
PIPER-ONE facility will be used to analyze their impact to the experimental prediction in Small Break
LOCA counterpart tests. The liquid level behavior in the core and the core cladding temperature analysis
are discussed used as judging criteria for the facilities scaling-up limits