Wide Diameter Implants Inserted in Jaws Grafted with Homologue Bone

Abstract

Svrha rada: Posljednjih deset godina povećala se uporaba implantata širokog promjera (WDI-a), posebice u lateralnim dijelovima čeljusti, uglavnom zbog dobrih kliničkih rezultata. No, malo je opisanih postupaka te objavljenih radova i ni jedan se ne bavi WDI-ma ugrađenima u transplantate homologne svježe zamrznute kosti (FFB-e). Zato smo obavili i retrospektivno istraživanje na nizu WDI-a postavljenih u homologne FFB-e, kako bismo ispitali kliničke rezultate. Materijal i metode: Ukupnom broju od 49 pacijenata ugrađeno je 126 WDI-a. Njih 35 imalo je dvostruko jetkanu površinu, 5 SLA1 površinu, 9 je bilo poprečno pjeskareno i jetkano kiselinom, 44 anodno oksidirano, 19 pjeskareno s CaPO4, 10 SLA2 površinu, a 4 su usatka imala neku drugu površinu. Rezultati: Samo jedan implantat bio je izgubljen (tj. SVR = 99,2%), a nije bilo razlike ni u ispitivanim varijablama. S druge strane, Coxova regresija pokazala je da su vrsta implantata (tj. dvostruko jetkana površina, površina pjeskarena CaPO4 i SLA2 površina) te njegova duæina (manja od 13 mm) u statistički znatnoj korelaciji s manjim gubitkom krestalne kosti, a time se omogućuje i bolji klinički ishod. Zaključak: Upotreba WDI-a u homolognom FFB-u može biti prihvatljiv način liječenja te može osigurati i neka poboljšanja, posebice u lateralnim dijelovima čeljusti za različita protetska rješenja poduprta usadcima.Objective of work: In the last decade the use of wide diameter implants (WDI) has increased especially in posterior jaws for their good clinical outcomes. However there are few reports on this topic and none on WDI inserted in homologue fresh frozen bone (FFB) grafts. Thus we planned a retrospective study on a series of WDI placed in homologuous FFB to evaluate the clinical outcome. Materials and Methods: 49 patients were operated on and 126 WDI inserted. There were 35 Double etched, 5 SLA1, 9 Grit blasted and acid etched, 44 Anodic Oxidized, 19 CaPo4 ceramic-blasted, 10 SLA2, and 4 miscellaneous implants. Results: Only 1 over in 126 WDI was lost (i.e. SVR = 99.2%) and no differences were detected among the studied variables. On the contrary, the Cox regression showed that implant type (i.e. Double etched, CaPo4 Ceramic-blasted, and SLA2) and implant length (i.e. length < 13 mm) correlated with a statistically signifi cant lower crestal bone loss and thus a better clinical outcome. Conclusion: The use of WDI inserted in homologuous FFB can be a viable treatment option and may provide benefi ts especially in posterior regions for the maintenance of various implant-supported prosthetic rehabilitations

    Similar works