Objectives:
The Prostate Imaging Quality (PI-QUAL) score assesses the quality of multiparametric MRI (mpMRI). A score of 1 means all sequences are below the minimum standard of diagnostic quality, 3 implies that the scan is of sufficient diagnostic quality, and 5 means that all three sequences are of optimal diagnostic quality. We investigated the inter-reader reproducibility of the PI-QUAL score in patients enrolled in the NeuroSAFE PROOF trial.
Methods:
We analysed the scans of 103 patients on different MR systems and vendors from 12 different hospitals. Two dedicated radiologists highly experienced in prostate mpMRI independently assessed the PI-QUAL score for each scan. Interobserver agreement was assessed using Cohen’s kappa with standard quadratic weighting (κw) and percent agreement.
Results:
The agreement for each single PI-QUAL score was strong (κw = 0.85 and percent agreement = 84%). A similar agreement (κw = 0.82 and percent agreement = 84%) was observed when the scans were clustered into three groups (PI-QUAL 1–2 vs PI-QUAL 3 vs PI-QUAL 4–5). The agreement in terms of diagnostic quality for each single sequence was highest for T2-weighted imaging (92/103 scans; 89%), followed by dynamic contrast-enhanced sequences (91/103; 88%) and diffusion-weighted imaging (80/103; 78%).
Conclusion:
We observed strong reproducibility in the assessment of PI-QUAL between two radiologists with high expertise in prostate mpMRI. At present, PI-QUAL offers clinicians the only available tool for evaluating and reporting the quality of prostate mpMRI in a systematic manner but further refinements of this scoring system are warranted