Investigation of optimal sample preparation conditions with potassium triiodide and optimal imaging settings for microfocus computed tomography of excised cat hearts

Abstract

OBJECTIVE: To determine optimal sample preparation conditions with potassium triiodide (I2KI) and optimal imaging settings for microfocus CT (micro-CT) of excised cat hearts. SAMPLE 7 excised hearts (weight range, 10 to 17.6 g) obtained from healthy adult cats after euthanasia by IV injection of pentobarbital sodium. PROCEDURES: Following excision, the hearts were preserved in 10% formaldehyde solution. Six hearts were immersed in 1.25% I2KI solution (n = 3) or 2.5% I2KI solution (3) for a 12-day period. Micro-CT images were acquired at time 0 (prior to iodination) then approximately every 24 and 48 hours thereafter to determine optimal sample preparation conditions (ie, immersion time and concentration of I2KI solution). Identified optimal conditions were then used to prepare the seventh heart for imaging; changes in voltage, current, exposure time, and gain on image quality were evaluated to determine optimal settings (ie, maximal signal-to-noise and contrast-to-noise ratios). Images were obtained at a voxel resolution of 30 mm. A detailed morphological assessment of the main cardiac structures of the seventh heart was then performed. RESULTS: Immersion in 2.5% I2KI solution for 48 hours was optimal for sample preparation. The optimal imaging conditions included a tube voltage of 100 kV, current of 150 mA, and exposure time of 354 milliseconds; scan duration was 12 minutes. CONCLUSIONS AND CLINICAL RELEVANCE: Results provided an optimal micro-CT imaging protocol for excised cat hearts prepared with I2KI solution that could serve as a basis for future studies of micro-CT for high resolution 3-D imaging of cat hearts

    Similar works