Purpose: The interpretation & correlation of the different
laboratory parameters in positive dengue cases in order to evaluate
that which laboratory test is more significant for diagnosis of Dengue.
Methods: Prospective examination of samples (patients\u2019 serum) for
dengue virus of different genotype by using multiplex anti-dengue IgM,
IgG. We have done NS-1 test by (ICT) immunochromatographic devices, and
complete blood picture (CBC) by Sysmex XP-100. Result: Detection of
Viral RNA in 100 patients showed effects in the total of 73 (73.0%)
samples. This graphical comparison shows the whole positive cases
including dengue NS-I antigen, dengue serology (IgM & IgG), total
62 positive cases of NS-I are detected, 10 positive cases of dengue IgM
and 9 positive cases of IgG detected, in which Complete Blood Test
(CBC) shows remarkable reduction in Platelets (32 cases) and Leucopenia
in (24 positive cases). Conclusion: In this research, it is concluded
that the diagnosis of dengue cases is preliminary limited to initial
stages i.e. CBC or sometimes dengue NS-I, as dengue IgM severity is
more effective than that of Dengue NS-I & IgG. Many patients who
had negative results in CBC and NS-1 testing, became positive when IgM
and IgG serology testing has been done