Wind loads on a house roof

Abstract

CER72-73KJD-JEC22.March 1973.Includes bibliographical references (pages 40-42).Prepared under National Bureau of Standards Contract No. NBS 273-70.Circulating copy deaccessioned 2020.The wind loads on the roof of a house were experimentally investigated by placing a 1:50 scale model house in a wind tunnel capable of generating thick, turbulent shear flows. The effects of roof geometry and wind direction were isolated by making the wind-tunnel flow representative of natural winds over very flat, open terrain. This flow simulation was accomplished by placing vortex generators at the entrance to the wind-tunnel test section. Mean pressures, root-mean-square values of the fluctuating pressures, and instantaneous peak pressures were measured at 11 preselected locations on the model's roof for 24 wind directions. A secondary purpose of the study was to determine the effects of an upwind fence on the roof pressures