Evaluation of incipient cavitation erosion for pipe wall at downstream of an orifice

Abstract

Cavitation induced vibration and the consequent erosion of pipes are the potential damaging factors in the piping systems. In order to prevent such trouble, it is preferable to develop a detection method for cavitation occurrence. Especially, in power plants, it is necessary to detect cavitation from the outside of the piping during operation. In this paper, in order to evaluate incipience of cavitation erosion, we carried out cavitation erosion experiments using aluminium specimens and we measured impulsive force induced by cavitation bubbles collapse using impact force detectors. In the cavitation erosion experiments, the incipient cavitation numbers, where cavitation erosion pits occured, were 0.8 at 50mm and 75mm downstream from the orifice and 0.7 at 100mm downstream. At those cavitation numbers, the states of cavitation was in a developed state or nearly so. In the measurements of impulsive force, the cavitation number, where impulsive force began to increase, was almost with the same as cavitation numbers at the occurrence of erosion pits.http://deepblue.lib.umich.edu/bitstream/2027.42/84261/1/CAV2009-final64.pd

    Similar works