CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Testing extraction and storage parameters for a fecal hormone method
Authors
Jacinta C. Beehner
David J. Pappano
Eila Kathleen Roberts
Publication date
1 November 2010
Publisher
Wiley Subscription Services, Inc., A Wiley Company
Doi
Cite
Abstract
Four experiments were conducted to test different aspects of a “field-friendly” fecal hormone extraction method that utilizes methanol extraction in the field followed by storage on C18 solid-phase extraction cartridges. Fecal samples were collected from geladas ( Theropithecus gelada ) housed at the Bronx Zoo, and the experiments were conducted in a laboratory setting to ensure maximum control. The experiments were designed to either simulate the conditions to which fecal samples are subjected during fieldwork or improve on an existing protocol. The experiments tested the relationship between fecal hormone metabolite preservation/recovery and: (1) the amount of time a sample is stored at ambient temperature; (2) the number of freeze/thaw cycles a sample undergoes; (3) the effectiveness of different extraction solutions; and (4) the effectiveness of different cartridge washes. For each experiment, samples were assayed by radioimmunoassay for fecal glucocorticoid (GC) and testosterone (T) metabolites. Results for each of the experiments were as follows. First, storage at ambient temperature did not affect hormone levels until 4 weeks of storage, with significant increases for both GC and T metabolites at 4 weeks. Second, hormone levels significantly decreased in samples after two freeze/thaw cycles for GCs and six freeze/thaws cycles for T. Third, for both GCs and T, hormone extraction using various methanol solutions was significantly higher than using 100% ethanol. Finally, using a 20% methanol solution to wash cartridges significantly increased GC levels but had no effect on T levels. These results suggest that, when utilizing C18 cartridges for fecal steroid storage, researchers should consider several methodological options to optimize hormone preservation and recovery from fecal samples. Am. J. Primatol. 72:934–941, 2010. © 2010 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/78062/1/20859_ftp.pd
Similar works
Full text
Available Versions
Deep Blue Documents at the University of Michigan
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:deepblue.lib.umich.edu:202...
Last time updated on 25/05/2012