Pérdida de fuerza y cambio estructural de cadenas elastomericas de tres diferentes marcas, inmersas en saliva artificial y bebida carbonatada Cusco 2020

Abstract

El presente trabajo de investigación cuyo epígrafe fue “PÉRDIDA DE FUERZA Y CAMBIO ESTRUCTURAL DE CADENAS ELASTOMERICAS DE TRES DIFERENTES MARCAS, INMERSAS EN SALIVA ARTIFICIAL Y BEBIDA CARBONATADA CUSCO 2020” tuvo como objetivo principal Determinar la pérdida de fuerza y cambio estructural de cadenas elastómericas de las marcas Ultra Chain, Morelli y Ormco inmersas en saliva artificial y bebida carbonatada, se realizó un estudio experimental in vitro, longitudinal, donde se analizaron 48 troqueles de los cuales 24 fueron sumergidos en saliva y 24 en bebida carbonatada, asimismo todos los troqueles fueron divididos en 6 grupos de 8 unidades de cada una de las marcas de cadenas elastómericas, las muestras fueron analizadas al 1er, 7mo, 14vo, 21vo y 28vo día de inmersión, se midieron las muestras con un dinamómetro para verificar la pérdida de fuerza de inicio a fin. Asimismo, se analizó la presencia grietas y erosiones medidas a través de un microscopio estereoscopio. Se obtuvo como datos resaltantes los siguientes: la pérdida de fuerza de las 3 marcas desde el día inicial que fue a 250g medido con un dinamómetro de la marca DVD dental, hasta el 28vo día con mediciones al 1er, 7mo, 14vo y 21vo día, donde en la Marca Ultra Chain de medias de 218.13 a 79.38 gr. desde el 1er al 28vo día de evaluación. Estas muestras estuvieron sumergidas en saliva; del mismo modo en bebida carbonatada se observa mayor pérdida al primer día con medias desde 200 a 75.63 gr. Se observa que en bebida carbonatada la marca Ultra Chain pierde más fuerza sumergida en bebida carbonatada (p<0.05). Al cambio estructural se observa mayor porcentaje de presencia de erosión y agrietamiento en los elastómeros sumergidos en bebida carbonatada sin embargo a la prueba estadística de Fisher no existen diferencias entre las dos muestras en cuanto al cambio estructural (p>0.05). La Marca Morelli tiene medias de 176.25 a 50.63 gr. desde el 1er al 28vo día de evaluación. Estas muestras estuvieron sumergidas en saliva; en el caso de bebida carbonatada se observa menor pérdida al primer día con medias desde 191.88 a 64.38 gr. Se observa que en bebida carbonatada la marca Morelli pierde más fuerza sumergida en bebida carbonatada (p<0.05). Al cambio estructural se observa mayor porcentaje de presencia de erosión y agrietamiento en los elastómeros sumergidos en bebida carbonatada sin embargo a la prueba estadística de Fisher no existen diferencias entre las dos muestras. La Marca Ormco tiene medias de 198.13 a 65.63 gr. desde el 1er al 28vo día de evaluación. Estas muestras estuvieron sumergidas en saliva; del mismo modo en bebida carbonatada se observa mayor pérdida al primer día con medias desde 193.13 a 54.38 gr. Se observa que en bebida carbonatada la marca Ormco pierde más fuerza sumergida en bebida carbonatada (p<0.05). Al cambio estructural se observa mayor porcentaje de presencia de erosión y agrietamiento en los elastómeros sumergidos en bebida carbonatada sin embargo a la prueba estadística de Fisher no existen diferencias entre las dos muestras (p>0.05). Conclusiones Se concluye que marca Morelli sumergida en saliva artificial y en bebida carbonatada mostro una caída de fuerza mucho más notoria que en relación a las otras marcas. También se concluye que la marca Ormco sumergida en saliva artificial y en bebida carbonatada mostro una caída mucho más lenta, pero sobre todo en menor cuantía que las otras marcas. También se concluye que la marca Ultra Chain sumergida en saliva artificial y en bebida carbonatada mostro una caída insignificante al pasar por todo el proceso. Además, podemos concluir que en relación al cambio estructural la marca Morelli fue la que tuvo mayor cambio estructural que las marcas Ultra Chain y Ormco.The present research work whose epigraph was "LOSS OF STRENGTH AND STRUCTURAL CHANGE OF ELASTOMERIC CHAINS OF THREE DIFFERENT BRANDS, IMMERSED IN ARTIFICIAL SALIVA AND CARBONATED DRINK CUSCO 2020" had as main objective To determine the loss of strength and structural change of elastomeric chains of the brands Ultra Chain, Morelli and Ormco immersed in artificial saliva and carbonated drink, an experimental in vitro study was carried out, A longitudinal in vitro experimental study was carried out, where 48 dies were analyzed, of which 24 were immersed in saliva and 24 in carbonated beverage, likewise all the dies were divided into 6 groups of 8 units of each of the brands of elastomeric chains, the samples were analyzed on the 1st, 7th, 14th, 21st and 28th day of immersion, the samples were measured with a dynamometer to verify the loss of strength from start to finish. The presence of cracks and erosions measured through a stereoscopic microscope was also analyzed. The following data were obtained as outstanding: the loss of strength of the 3 brands from the initial day which was 250g measured with a dynamometer of the DVD dental brand, until the 28th day with measurements at the 1st, 7th, 14th and 21st day, where in the Ultra Chain brand from 218.13 to 79.38 gr. averages from the 1st to the 28th day of evaluation. These samples were submerged in saliva; similarly, in carbonated beverage, a greater loss is observed on the first day with averages from 200 to 75.63 gr. It is observed that in carbonated beverage the Ultra Chain brand loses more strength submerged in carbonated beverage (p<0.05). At the structural change, a higher percentage of erosion and cracking is observed in the elastomers submerged in carbonated beverage; however, at Fisher's statistical test, there are no differences between the two samples in terms of structural change (p>0.05). The Morelli Brand has means from 176.25 to 50.63 gr. from the 1st to the 28th day of evaluation. These samples were immersed in saliva; in the case of carbonated beverage, less loss is observed on the first day with means from 191.88 to 64.38 gr. It is observed that in carbonated beverage the Morelli brand loses more strength submerged in carbonated beverage (p<0.05). At the structural change, a higher percentage of erosion and cracking is observed in the elastomers submerged in carbonated beverage; however, at Fisher's statistical test, there are no differences between the two samples. The Ormco brand has means from 198.13 to 65.63 gr. from the 1st to the 28th day of evaluation. These samples were immersed in saliva; in the same way in carbonated beverage a greater loss is observed on the first day with means from 193.13 to 54.38 gr. It is observed that in carbonated beverage the Ormco brand loses more strength submerged in carbonated beverage (p<0.05). At the structural change, a higher percentage of erosion and cracking is observed in the elastomers submerged in carbonated beverage; however, at Fisher's statistical test, there are no differences between the two samples (p>0.05). Conclusions It is concluded that the Morelli brand immersed in artificial saliva and in carbonated beverage showed a much more noticeable drop in strength than the other brands. It is also concluded that the Ormco brand immersed in artificial saliva and in carbonated beverage showed a much slower drop, but above all a smaller amount than the other brands. It is also concluded that the Ultra Chain brand immersed in artificial saliva and carbonated beverage showed a negligible drop when going through the whole process. Furthermore, we can conclude that in relation to structural change, the Morelli brand had the greatest structural change compared to the Ultra Chain and Ormco brands

    Similar works