Evaluation of left ventricular ejection fraction as a measure of pump performance in patients with chronic mitral regurgitation

Abstract

Left ventricular (LV) ejection fraction may not adequately detect a reduction in LV systolic performance resulting from chronic mitral regurgitation (MR), due to ventricular unloading into the low-impedance left atrium. To determine whether LV ejection fraction sufficiently gauges myocardial function in MR, nine patients were studied using micromanometer-measured LV pressures and biplane cineventriculography before and 1 year after mitral valve surgery. Six control patients were also studied. LV ejection fraction was normal in MR patients, despite an increase in LV end-systolic volume index. LV end-systolic pressure-volume and stress-volume ratios in MR patients were lower than in controls ( P < 0.05 and P < 0.01), suggesting that LV systolic performance fell. One year after mitral valve surgery, LV ejection fraction decreased ( P < 0.05) even though LV end-systolic volume index ( P < 0.05), pressure-volume ( P < 0.05), and stress-volume ratios ( P < 0.01) all improved. Thus, LV ejection fraction inadequately reflected LV systolic function in MR patients before and after mitral valve surgery. Cathet. Cardiovasc. Intervent. 49:290–296, 2000. © 2000 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/35248/1/14_ftp.pd