Analysis of thermal properties, water vapor resistance and radiant heat transmission through different combinations of firefighter protective clothing

Abstract

This experimental work is an effort to seek the possibility of improvement in thermal protective performance of firefighter protective clothing at different levels of heat flux density. Improvement in thermal protective performance means enhancement in the time of exposure against the heat flux, which will provide extra time to firefighters to perform their duties without suffering from severe injuries. Four different multilayer combinations of firefighter protective clothing were investigated. Each combination consists of outer shell, moisture barrier and thermal liner. Aerogel sheet was also employed as a substitute to thermal barrier. Initially, properties like thermal resistance, thermal conductivity. and water vapor resistance of multilayer fabric assemblies were investigated. Later on these combinations were exposed to different levels of radiant heat flux density i.e. at 10, 20 and 30 kW/m(2) as per ISO 6942 standard. It was noted that those combinations in which aerogel blanket was used as thermal barrier acquire greater thermal resistance, water vapor resistance and have less transmitted heat flux density values

    Similar works

    Full text

    thumbnail-image

    Available Versions