[EN] Bubble chambers used in detectors for detecting dark
matter use piezoelectric sensors in order to detect and
discriminate the acoustic signals from bubbles growth in
the superheated liquid when a particle interaction occurs.
The Research Group in Applied Acoustics to Astroparticles
Detection from UPV developed a particle detector,
whose acoustic sensors are attached to the outer walls
of the chamber. In order to optimize the operation of the
sensor, both analytical and numerical models are developed,
as well as experimental tests for characterization
of sensors design were performed. The results of these
studies allows a particular design criterion for the construction
of such sensor for future dark matter bubble
chamber detectors.[ES] Las cámaras de burbujas empleadas en los detectores
para la detección de materia oscura, utilizan sensores piezoeléctricos
para detectar y discriminar las señales acústicas
emitidas por las burbujas que se generan a partir de la interacción
de partículas con el fluido sobrecalentado presente
en el interior de dicha cámara. El grupo de Investigación en
Acústica Aplicada a la Detección de Astropartículas de la
UPV ha desarrollado un modelo de detector de partículas,
cuyos sensores acústicos se encuentran pegados en las paredes
exteriores de la cámara. Con el objetivo de entender el
comportamiento y optimizar el funcionamiento del sensor, se
desarrollan modelos analíticos y numéricos, así como pruebas
experimentales para su caracterización. Los resultados
de estos estudios permiten tener un criterio de diseño para
la adecuada construcción de tales sensores en futuras cá-
maras de burbujas para la detección de materia oscuraCampo-Valera, MM.; Ardid Ramírez, M.; Felis-Enguix, I.; Martínez Mora, JA. (2018). Simulación y diseño de un sensor acústico piezoeléctrico para detección de partículas. Revista de Acústica. 49(1-2):11-18. http://hdl.handle.net/10251/102342S1118491-