Abstract

In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration a -500 kV, 250 ns FWHM, pulse will be applied in between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgass and must not emit electrons. Ion back bombardment, and dark current will be damageable to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel, titanium and molybdenum were tested following different procedures including plasma glow discharge cleaning.Comment: 22 pages, 6 tables, 10 figures Vs 2 : graphics more readable, enhanced content Vs 3 : typo correcte

    Similar works

    Full text

    thumbnail-image

    Available Versions

    Last time updated on 23/03/2019