This paper addresses an important issue raised for the clinical relevance of
Computer-Assisted Surgical applications, namely the methodology used to
automatically build patient-specific Finite Element (FE) models of anatomical
structures. From this perspective, a method is proposed, based on a technique
called the Mesh-Matching method, followed by a process that corrects mesh
irregularities. The Mesh-Matching algorithm generates patient-specific volume
meshes from an existing generic model. The mesh regularization process is based
on the Jacobian matrix transform related to the FE reference element and the
current element. This method for generating patient-specific FE models is first
applied to Computer-Assisted maxillofacial surgery, and more precisely to the
FE elastic modelling of patient facial soft tissues. For each patient, the
planned bone osteotomies (mandible, maxilla, chin) are used as boundary
conditions to deform the FE face model, in order to predict the aesthetic
outcome of the surgery. Seven FE patient-specific models were successfully
generated by our method. For one patient, the prediction of the FE model is
qualitatively compared with the patient's post-operative appearance, measured
from a Computer Tomography scan. Then, our methodology is applied to
Computer-Assisted orbital surgery. It is, therefore, evaluated for the
generation of eleven patient-specific FE poroelastic models of the orbital soft
tissues. These models are used to predict the consequences of the surgical
decompression of the orbit. More precisely, an average law is extrapolated from
the simulations carried out for each patient model. This law links the size of
the osteotomy (i.e. the surgical gesture) and the backward displacement of the
eyeball (the consequence of the surgical gesture)