We present designs for Ioffe-Pritchard type magnetic traps using planar
patterns of hard magnetic material. Two samples with different pattern designs
were produced by spark erosion of 40 μm thick FePt foil. The pattern on the
first sample yields calculated axial and radial trap frequencies of 51 Hz and
6.8 kHz, respectively. For the second sample the calculated frequencies are 34
Hz and 11 kHz. The structures were used successfully as a magneto-optical trap
for 87Rb and loaded as a magnetic trap. A third design, based on
lithographically patterned 250 nm thick FePt film on a Si substrate, yields an
array of 19 traps with calculated axial and radial trap frequencies of 1.5 kHz
and 110 kHz, respectively.Comment: 8 pages, 5 figures Revised and accepted for EPJD, improved picture