research

The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit

Abstract

A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 μ\mum above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.Comment: 15 pages, 9 included postscript figures, 5 separate jpeg figures, submitted to Nucl. Instr. and Meth. A. A complete postscript version with high resolution figures 1, 3, 11, 12 and 14 can be found at http://www.nikhef.nl/~i06/RandD/final/letter4.p