A simple and non-destructive method for identification of a single molecular
ion sympathetically cooled by a single laser cooled atomic ion in a linear Paul
trap is demonstrated. The technique is based on a precise determination of the
molecular ion mass through a measurement of the eigenfrequency of a common
motional mode of the two ions. The demonstrated mass resolution is sufficiently
high that a particular molecular ion species can be distinguished from other
equally charged atomic or molecular ions having the same total number of
nucleons