The sensitivity of experiments searching for neutrinoless double beta-decay
of germanium was so far limited by the background induced by external
gamma-radiation. Segmented germanium detectors can be used to identify photons
and thus reduce this background component.
The GERmanium Detector Array, GERDA, will use highly segmented germanium
detectors in its second phase. The identification of photonic events is
investigated using a prototype detector. The results are compared with Monte
Carlo data.Comment: 20 pages, 7 figures, to be submitted to NIM-