57,336 research outputs found
Receipt from Metropolitan Glazing Co.
https://digitalcommons.salve.edu/goelet-new-york/1201/thumbnail.jp
Analysis of Flexural Strength and Contact Pressure After Simulated Chairside Adjustment of Pressed Lithium Disilicate Glass-Ceramic
Statement of problem Research evaluating load-to-failure of pressed lithium disilicate glass-ceramic (LDGC) with a clinically validated test after adjustment and repair procedures is scarce. Purpose The purpose of this in vitro study was to investigate the effect of the simulated chairside adjustment of the intaglio surface of monolithic pressed LDGC and procedures intended to repair damage. Material and methods A total of 423 IPS e.max Press (Ivoclar Vivadent AG) disks (15 mm diameter, 1 mm height) were used in the study. The material was tested by using an equibiaxial loading arrangement (n≥30/group) and a contact pressure test (n≥20/group). Specimens were assigned to 1 of 14 groups. One-half was assigned to the equibiaxial load test and the other half underwent contact pressure testing. Testing was performed in 2 parts, before glazing and after glazing. Before-glazing specimens were devested and entered in the test protocol, while after-glazing specimens were devested and glazed before entering the test protocol. Equibiaxial flexure test specimens were placed on a ring-on-ring apparatus and loaded until failure. Contact pressure specimens were cemented to epoxy resin blocks with a resin cement and loaded with a 50-mm diameter hemisphere until failure. Tests were performed on a universal testing machine with a crosshead speed of 0.5 mm/min. Weibull statistics and likelihood ratio contour plots determined intergroup differences (95% confidence bounds). Results Before glazing, the equibiaxial flexural strength test and the Weibull and likelihood ratio contour plots demonstrated a significantly higher failure strength for 1EC (188 MPa) than that of the damaged and/or repaired groups. Glazing following diamond-adjustment (1EGG) was the most beneficial post-damage procedure (176 MPa). Regarding the contact pressure test, the Weibull and likelihood ratio contour plots revealed no significant difference between the 1PC (98 MPa) and 1PGG (98 MPa) groups. Diamond-adjustment, without glazing (1EG and 1PG), resulted in the next-to-lowest equibiaxial flexure strength and the lowest contact pressure. After glazing, the strength of all the groups, when subjected to glazing following devesting, increased in comparison with corresponding groups in the before-glazing part of the study. Conclusions A glazing treatment improved the mechanical properties of diamond-adjusted IPS e.max Press disks when evaluated by equibiaxial flexure and contact pressure tests. Clinical Implications When adjustments are made on the intaglio surface of a pressed lithium disilicate glass-ceramic, a subsequent glazing treatment is recommended to improve strength
The influence of a high power diode laser (HPDL) generated glaze on the wetting characteristics and the subsequent HPDL enamelling of ordinary Portland cement
High power diode laser (HPDL) surface glazing of the ordinary Portland cement (OPC) surface of concrete was found to effect significant changes in the wettability characteristics of the OPC. This behaviour was identified as being primarily due to: (i) the polar component of the OPC surface energy increasing after HPDL glazing from 3.46 to 15.56 mJm-2, (ii) the surface roughness of the OPC decreasing from an Ra value of 21.91 to 2.88 m after HPDL glazing and (iii) the relative surface O2 content of the OPC increasing by 4.5at% after HPDL glazing. HPDL glazing was consequently identified as occasioning a decrease in the enamel contact angle from an initial value of 1090 to 310, thus allowing the vitreous enamel to wet the OPC surface
Studying the Impact of Colored Glazing Systems on Visual and Non-visual Performances in a Daylit Office
This article first presents a full-scale survey of the impact of colored/neutral glazing systems on occupants’ visual and non-visual performances, and working performance in a daylit office in Beijing, China. Five glazing systems were investigated during a heating season from 17 November 2016 to 11 January 2017. The lighting measurements and subjective assessments were conducted to find the relationship between lighting conditions, glazing types, and visual and non-visual performances and working performance. Several main findings are achieved as follows: 1) According to the visual performances, the blue glazing could be the best solution while the bronze glazing tend to be less acceptable; the grey and green glazing systems did not show significant differences from the clear glazing. 2) No clear differences of non-visual performances can be found between various colored/neutral glazing systems. 3) The circadian light has a significant link to occupants’ non-visual performances. 4) Participants tend to get a worse performance in short-term test of GONOGO working with the occurrence of the blue glazing system
EFFECTS OF LOUVERS SHADING DEVICES ON VISUAL COMFORT AND ENERGY DEMAND OF AN OFFICE BUILDING. A CASE OF STUDY
This paper evaluates the building energy demand and visual comfort of a real case
with a glazed façade office building placed in Málaga (Mediterranean city in the south of
Spain). South oriented facades receive such a high solar gain that cooling demand cannot
be handled by the current HVAC system. As an environmental friendly solution, a shading
control strategy based on vertical and horizontal louvers is proposed.
The study consists of a comparison between the actual and the refurbished building
with shading devices. Daylighting simulation is done with Daysim (Daysim, 2016). A
group of offices with south, east and north oriented facades is chosen for the study. Horizontal
louvers in the south façade and vertical louvers in the east facade are modelled
and simulated. The simulation changes the angle of the louver: 0º (perpendicular to the
glazing), -30º, 30º, -60º, 60º. Visual comfort parameters analyzed are: illuminance, daylight
autonomy (DA) and useful daylight index (UDI). With respect to the thermal comfort,
not only louvers orientation try to provide solar protection for glazed areas in cooling
period but also maximize solar gains in heating period. However, an excessive daylight
could affect discomfort glare. Shading control strategy must provide the equilibrium
between both aspects. Thermal demand is calculated with Trnsys (TRNSYS, 2016).Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech
Evacuated glazing with tempered glass
The application of tempered glass has made it possible to significantly reduce the support pillar number within evacuated glazing (EG) since tempered glass (T-glass) is four to ten times mechanically stronger than annealed glass (A-glass). The thermal transmittance (U-value) of 0.4 m by 0.4 m double evacuated glazing (DEG) with 4 mm thick T-glass and A-glass panes with emittance of 0.03 were determined to be 0.3 Wm−2K−1 and 0.57 Wm−2K−1, respectively (47.4% improvement) using previously experimentally validated finite volume model. The thermal transmittance (U-value) of 0.4 m by 0.4 m triple evacuated glazing (TEG) with 4 mm thick T-glass and A-glass panes with emittance of 0.03 were determined to be 0.11 Wm−2K−1 and 0.28 Wm−2K−1, respectively (60.7% improvement). The improvement in the U-value of EG with T-glass is due to a reduction in support pillar number, leading to reduction in heat conduction through pillar array. The impact of tempered glass on the thermal transmittance for TEG is greater than that of DEG since radiative heat transfer in TEG is much lower than that in DEG, thus the reduction in heat conduction resulted from the reduction of support pillar number in TEG is much larger than that in DE
Using of aerogel to improve thermal insulating properties of windows
For the best possible thermal-technical properties of building structures it is necessary to use materials with very low thermal conductivity. Due to the increasing thermal-technical requirements for building structures, the insulating materials are developed. One of the modern thermal insulating materials is so-called aerogel. Unfortunately, this material is not used in the field of external thermal insulation composite systems because of its price and its properties. The aim of this paper is to present possibilities of using this insulating material in the civil engineering - specifically a usage of aerogel in the production of windows.Web of Science14111
Living with helicopter noise : evaluating sound insulation techniques for domestic dwellings using real helicopters
Specific remedial works designed to improve sound installation and reduce the noise level produced by helicopters inside dwellings are described. The theoretical problems and practical solutions to installing high performance acoustic insulation to a traditional property in the UK are presented. A novel application of ISO 140-5 is presented using real helicopters to measure sound insulation in-situ in the presence of multiple flanking transmission paths. Dedicated field trials to evaluate the performance of such acoustic double-glazing and associated modifications systems were performed and the precautions taken to minimise measurement uncertainties over the extended time period of the trials are detailed. The field trials involved the use of military training helicopters following selected flight paths around the property while noise level measurements were made internally and externally, before and after replacement of the existing single glazed windows and attenuated ventilation units were installed. The results show that after replacing the main windows with acoustic insulated glazing units, insulation levels of 40dB or above are achieved in most rooms. The results also illustrate the importance of effectively addressing ventilation when windows are replaced. It is concluded that despite complications due to sound flanking and regulatory ventilation, the use of acoustic double-glazing units and properly attenuated ventilation units can effectively reduce helicopter noise in suitable dwellings
Case studies of outdoor testing and analysis of building components
The construction and development of the PASSYS/PASLINK outdoor test cells were funded by the European Commission, with the objective of providing high-quality test environments for quantifying the performance of passive solar building components. Over the years since the original test cells were commissioned, the initial concept for outdoor testing has been extended to include other test cell types. Significant improvements have been made to the experimental procedures and analysis techniques, and a broad range of components has been tested. This paper describes representative experiments that have been conducted using these highly controlled outdoor test environments, indicates some of the related analysis, and shows the type of information that can be obtained from such tests. It demonstrates the way in which component performance can be ascertained in the realistic external environment. The case studies chosen range from building component tests within EC research projects to commercial tests, and from conventional building components to novel integrated facade systems. They also include a large range of passive and active components. Each case study summarises the test component, the purpose of the test, details of the test configuration (period of test, instrumentation, etc.), results and analysis, and associated modelling and monitoring where appropriate. The paper concludes with an appraisal of the advantages and limitations of the test cells for the various component types
A comparative study of the surface glaze characteristics of concrete treated with CO2 and high power diode lasers. Part II: mechanical, chemical and physical properties
The hardened ordinary Portland cement (OPC) surface layer of concrete which was glazed using a
CO2 and a high power diode laser (see Part I of this paper) has been tested in order to determine the
mechanical, chemical and physical characteristics of the glazes. The work showed that the generation
of the surface glazes resulted in improved mechanical, chemical and physical properties over the
untreated OPC surface of concrete. However, differences in the performance of the CO2 and HPDL
generated glazes were observed. These are believed to be due to the differences in the morphology
and microstructure of the glazes generated as a result of the differing beam absorption characteristics
of the two lasers. Life assessment testing revealed that the laser glazed OPC surfaces effected an
increase in actual wear life of 1.3 to 17.7 times over the untreated OPC surface of concrete depending
upon the corrosive environment
- …
