Computerized tomography calibrator
A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces
Inconsistent stimulation of plasma ACTH through corticotropin-releasing factor in a patient with central Cushing's disease due to pituitary adenoma
Three uncommon findings were observed in a case of Cushing's disease due to macroadenoma: no suppression of plasma ACTH during an 8-mg dexamethasone test, a negative corticotropin-releasing factor test, and a normal X-ray of the sella turcica. Despite these findings, the diagnosis of pituitary was confirmed Cushing's syndrome by computerized tomography and a transphenoidal operation
Accuracy of computerized tomography in determining hepatic tumor size in patients receiving liver transplantation or resection
Computerized tomography (CT) of liver is used in oncologic practice for staging tumors, evaluating response to treatment, and screening patients for hepatic resection. Because of the impact of CT liver scan on major treatment decisions, it is important to assess its accuracy. Patients undergoing liver transplantation or resection provide a unique opportunity to test the accuracy of hepatic-imaging techniques by comparison of finding of preoperative CT scan with those at gross pathologic examination of resected specimens. Forty-one patients who had partial hepatic resection (34 patients) or liver transplantation (eight patients) for malignant (30 patients) or benign (11 patients) tumors were evaluable. Eight (47%) of 17 patients with primary malignant liver tumors, four (31%) of 13 patients with metastatic liver tumors, and two (20%) of 10 patients with benign liver tumors had tumor nodules in resected specimens that were not apparent on preoperative CT studies. These nodules varied in size from 0.1 to 1.6 cm. While 11 of 14 of these nodules were 1.0 cm. These results suggest that conventional CT alone may be insufficient to accurately determine the presence or absence of liver metastases, extent of liver involvement, or response of hepatic metastases to treatment
Direct observation of the phonon energy in a Bose-Einstein condensate by tomographic imaging
The momentum and energy of phonons in a Bose-Einstein condensate are measured
directly from a time-of-flight image by computerized tomography. We find that
the same atoms that carry the momentum of the excitation also carry the
excitation energy. The measured energy is in agreement with the Bogoliubov
spectrum. Hydrodynamic simulations are performed which confirm our observation.Comment: Letter, 5 figure
Focal Spot, Winter 1975
https://digitalcommons.wustl.edu/focal_spot_archives/1013/thumbnail.jp
Focal Spot, Spring 1978
https://digitalcommons.wustl.edu/focal_spot_archives/1020/thumbnail.jp
Imaging for endoscopic sinus surgery in adults
Computerized tomography (CT) offers the gold standard in terms of imaging the extent of disease and the fine detailed anatomy, both pre-requisites to the safe practice of endoscopic sinus surgery. Neither plain X-rays nor magnetic resonance imaging (MRI) offer optimal information in this respect. A variety of protocols minimizing radiation dose to the lens whilst providing high quality images are presented together with a menu of anatomical features that require careful evaluation pre-operatively
Stripe sensor tomography
We introduce a general concept of tomographic imaging for the case of an imaging sensor that has a stripelike shape. We first show that there is no difference, in principle, between two-dimensional tomography using conventional electromagnetic or particle radiation and tomography where a stripe sensor is mechanically scanned over a sample at a sequence of different angles. For a single stripe detector imaging, linear motion and angular rotation are required. We experimentally demonstrate single stripe sensor imaging principle using an elongated inductive coil detector. By utilizing an array of parallel stripe sensors that can be individually addressed, two-dimensional imaging can be performed with rotation only, eliminating the requirement for linear motion, as we also experimentally demonstrate with parallel coil array. We conclude that imaging with a stripe-type sensor of particular width and thickness (where the width is much larger than the thickness) is resolution limited only by the thickness (smaller parameter) of the sensor. We give examples of multiple sensor families where this imaging technique may be beneficial such as magnetoresistive, inductive, superconducting quantum interference device, and Hall effect sensors, and, in particular, discuss the possibilities of the technique in the field of magnetic resonance imaging
Optimum imaging for mucoceles
A mucocele is an epithelial lined mucus-containing sac completely filling a paranasal sinus and capable of expansion. They are relatively unusual, occurring most frequently in the fronto-ethmoidal region. The imaging features on plain X-ray, computerized tomography and magnetic resonance imaging are relatively characteristic allowing distinction of the lesion from other pathologies in this area although the mucoceles may occur in association with other pathologies such as nasal polyposis and neoplasia
Digital 3D reconstruction of historical textile fragment
This paper presents a new methodology for reproducing historic fragment in 3D with realistic behaviour, providing users with a feel for the fragment detailing. The fragment piece originates from the English National Trust archive held in the collection at Claydon House. The aim is to utilize a combination of both 2D pattern software and state-of-the-art 3D technology to recreate a compelling and a highly realistic representation of historic fragment. The process starts with investigation of the textile construction. Textile fragments will be incomplete and/or have a level of deterioration therefore various recording techniques are to be explored. A combination of both photography and 3D scanning technology will be utilized throughout the methodology to accurately record the digital data. The equipment setting will be analyzed in order to produce an accurate working method. This paper forming part of a larger study, will specifically focus on the methodology for recording data from one fragment piece
- …