45 research outputs found
Вычисление средних хронологических значений – незаслуженно забытый способ статистической обработки
In real analytical practice involving parallel determinations there are certain objective reasons (limited measurement time, available resources, etc.) that prevent performing sufficient number of measurements required for rigorous statistical data processing. Such parameters as standard deviations are particularly unreliable for small data sets (they are usually too high in comparison with the results obtained for more representative data sets). This problem can be minimized by changing the character of data processing, i.e. calculating so-called chronological averages instead of average arithmetical values. This, however, requires ranking the data not in the order as they were measured, but in the ascending order.The essence of calculating chronological averages is that the minimum and the maximum values of the initial data set are replaced with a single number, namely their arithmetical average, which is then averaged with other data. As a result, the total number of data values decreases by one but the changes of the averages would be negligible. At the same time, the standard deviations of the modified data sets become more characteristic and approaching the standard deviations of extended data sets.Replacing the arithmetical means by chronological average values leads to sufficiently smaller distortions of the initial data sets than, for example, in the case of excluding outliers by using the well-known “3s” criterion.Keywords: Statistical processing of single-dimensional data sets, small data sets, average chronological values, standard deviations, interpretationВ реальной аналитической практике при выполнении так называемых параллельных определений существуют объективные причины (ограниченные время измерений, материальные ресурсы и другие факторы), которые не позволяют обеспечить достаточное число измерений, необходимых для их надежной статистической обработки. Особенно ненадежными для малых выборок данных представляются стандартные отклонения (чаще всего завышены). Однако если изменить характер их статистической обработки и вместо средних арифметических значений вычислять средние хронологические значения и соответствующие им стандартные отклонения, то этот прием позволяет получать более надежные результаты. Это требует ранжирования исходных данных не в последовательности их измерения, а по возрастанию.Суть вычисления средних хронологических в том, что минимальное и максимальное значения исходной выборки заменяют одним числом, а именно – их средним арифметическим, которое далее усредняют вместе с остальными. В результате этого количество измерений формально уменьшается на единицу, но средние значения изменяются лишь незначительно. Значения же стандартных отклонений, вычисленные после такой модификации выборки, становятся более характеристичными и приближаются к значениям стандартных отклонений выборок данных большего объема.Переход от средних арифметических к средним хронологическим приводит к существенно меньшим искажениям исходных выборок данных чем, например, исключение выбросов с использованием известного критерия 3s. Ключевые слова: Статистическая обработка одномерных совокупностей данных, малые выборки, средние хронологические значения, стандартные отклонения, интерпретация
Features and New Examples of Gas Chromatographic Separation of Thermally Unstable Analytes
The processes of thermal decomposition of analytes in gas chromatographic (GC) columns are classified and two new examples of them are considered in details. First of them is monomolecular decomposition of monoalkyl esters of benzene-1, 2-dicarboxylic (phthalic) acid (monoalkyl phthalates). This process has the analogy in chemical reactions in solutions and it may be responsible for the toxicity of phthalates. The second example is decomposition of non-substituted hydrazones of both aliphatic and aromatic carbonyl compounds. The analytes of the second sub-group present the first example of bimolecular (second order) decomposition in a GC column: two molecules of hydrazones form stable azines and hydrazine. Besides that this process presents the particular interest, because it is accompanied by secondary chemical reactions not in an injector, but within GC column, when a by-product of decomposition is involved into secondary interaction with other constituents of the samples. It was confirmed, that visual images of all these decomposition processes on the chromatograms are rather identical and coincide with the manifestations of interconversion of isomers or tautomers. The most often expressed features of chromatographic profiles in such cases are the presence of peaks of an initial analyte and a product of its decomposition or isomerization, connected with more or less expressed diffused “plateau” or “train” between them. The decomposition processes during sample preparation prior to chromatographic separation or in the heated injector of GC instrument are not accompanied by such features. Despite of the rather “exotic” character of the examples considered, the knowledge of them seems to be useful for better revealing the analogous situations in chromatographic practice. Thermal instability of analytes is the principal restriction of GC separation of reactive compounds and we cannot eliminate it for objective reasons. However, in some cases we can evaluate the temperature limits of chromatographic columns, which should not be exceeded during GC separation of instable compounds. The simplest (low boiling) homologs of thermally unstable compounds are often characterized by “normal” boiling point at atmospheric pressure (Tb, °C) without decomposition, that means the possibility of their GC analysis unambiguously. Therefore, we can select such Tb values as GC and/or GC–MS temperature limit (Tlim) for other members of series of thermally unstable homologs. If GC separation is carried out not in isothermal, but in temperature programming conditions, so-called retention temperature (TR) of unstable analytes should not exceed the evaluated Tlim value
ОСОБЕННОСТИ ДОЗИРОВАНИЯ И ХРОМАТОГРАФИЧЕСКОГО РАЗДЕЛЕНИЯ ПРОБ В ВЫСОКОКИПЯЩИХ ВЯЗКИХ ОРГАНИЧЕСКИХ РАСТВОРИТЕЛЯХ С ИСПОЛЬЗОВАНИЕМ КАПИЛЛЯРНЫХ КОЛОНОК ПРИ МАЛОМ ДЕЛЕНИИ ПОТОКА ГАЗА-НОСИТЕЛЯ
The features of injection and gas chromatographic separation of stock analytes in their solutions in high boiling viscous polar organic solvents (on the example of 1,3-butanediol) using a short capillary column of large internal diameter (Megabore type) at low split ratios are considered. The manifestation of so-called discrimination effects is confirmed, with the main of them being the dependence of absolute peak areas vs. injection temperature as well as similar dependence of relative peak areas in different solvents. However, these effects are manifested in a lesser degree than the same effects for the samples dissolved in low boiling solvents. It is demonstrated that the dependencies of peak areas vs. injector temperature (S = aT + b) are principally different for solvents with various boiling points. Thus, for the solutions of butyl acetate, cyclohexanone, anisol, butyl butyrate, and acetophenone in low boiling 2-propanol the linear dependencies S(T) are revealed for the injector temperature range of 120-180°С only (with correlation coefficients r = 0.986 – 0.999), while at the higher injector temperatures (210-240°С) the significant deviations from linearity are typical. At the same time, the solutions of the same components in higher boiling 1,3-butanediol demonstrate the linear S(T) dependencies within the whole temperature range (120-240°С). It is confirmed that the discrimination effects have no significant influence on the results of gas chromatographic analyses of the samples in high boiling solvents if the method of internal normalization is used. The main uncertainties of the results are caused by the column’s overloading with the solvent, which leads to the broadening and asymmetry of its peaks and their overlapping with the peaks of some analytes.DOI: http://dx.doi.org/10.15826/analitika.2018.22.3.005Keywords: High boiling viscous organic solvents, gas chromatographic analysis, capillary columns, discrimination effects(Russian)Igor G. Zenkevich, Eugene Leleev St. Petersburg State University,Russian Federation, 198504, St. Petersburg, Universitetskii prosp., 26Рассмотрены особенности дозирования и газохроматографического разделения модельных аналитов в их растворах в высококипящих полярных органических растворителях (на примере 1,3-бутандиола) с использованием короткой капиллярной колонки большого внутреннего диаметра (типа Megabore) и малых значениях деления потока газа-носителя. Подтверждено проявление эффектов дискриминации, основными из которых оказываются зависимости абсолютных площадей пиков аналитов от температуры испарителя и аналогичные зависимости относительных площадей пиков одних и тех же компонентов в различных растворителях. Показано, что такие эффекты выражены в меньшей степени, чем при использовании низкокипящих растворителей. Показано, что характер зависимости площадей пиков от температуры испарителя (S = aT + b) принципиально различен для растворителей с различными температурами кипения. Так, для растворов бутилацетата, циклогексанона, анизола, бутилбутирата и ацетофенона в низкокипящем 2-пропаноле в интервале температур испарителя 120-180 °С выявлены линейные зависимости S(T) с коэффициентами корреляции r = 0.986 – 0.999, тогда как для больших температур испарителя (210-240 °С) типичны существенные отклонения от линейности. Для растворов этих же компонентов в высококипящем 1,3-бутандиоле линейные зависимости S(T) наблюдаются во всем интервале температур 120-240°С. Подтверждено, что, так же как и в случае низкокипящих растворителей, эффекты дискриминации слабо влияют на результаты обработки данных газохроматографического анализа образцов в вязких высококипящих растворителях способом внутренней нормализации. Основные погрешности результатов связаны с перегрузкой хроматографической колонки по растворителю, что приводит к значительному уширению его пиков, их асимметрии и перекрыванию с сигналами некоторых целевых аналитов.Ключевые слова: высококипящие вязкие органические растворители, газохроматографический анализ, капиллярные колонки, эффекты дискриминацииDOI: http://dx.doi.org/10.15826/analitika.2018.22.3.00
АНАЛИТИЧЕСКИЕ АСПЕКТЫ ЗАВИСИМОСТИ ИНДЕКСОВ УДЕРЖИВАНИЯ ОРГАНИЧЕСКИХ СОЕДИНЕНИЙ В ОБРАЩЕННО-ФАЗОВОЙ ВЭЖХ ОТ СОДЕРЖАНИЯ МЕТАНОЛА В СОСТАВЕ ЭЛЮЕНТА
As a result of the determination of retention indices (RI) of 11 organic compounds of various polarity in reversed phase (RP) HPLC using methanol as organic solvent in eluent, the coefficients of the dependence of RI vs. content of methanol, dRI/dС were determined. Formally, these parameters are equivalent to the temperature coefficients of gas chromatographic retention indices, b = dRI/dT. It is shown that the ranges of variations of these coefficients are rather large (from -2.0 up to +4.6 in the current work), which requires revealing the factors influencing their signs and absolute values. The correlations of coefficients dRI/dC with retention indices themselves, as well as with hydrophobicity factors, logP (the logarithms of partition coefficients in the system 1-octanol/water) seem to be negligible. The best correlations of dRI/dC were observed with such polarity measures of organic compounds as homologous increments of hydrophobicity factors (ilogP), and retention indices (iRI). Such transformations of properties A as their homologous increments characterize different homologues despite of their locations within the homologous series. Thus, the parameters ilogP and iRI appeared to be the measures of the polarity of the corresponding series. This approach permits us to reveal that the dependence of retention indices in RP HPLC on the content of methanol in eluent is determined just by the analytes¢ polarity and their hydrophobic – hydrophilic properties. The ratio dRI/dC 0 is typical for non-polar analytes, while for polar compounds the negative signs of these coefficients are typical, dRI/dC 0. Hence, determining even the sign of this coefficient provides the important information on the chemical origin of analytes.Keywords: Reversed-phase high performance liquid chromatography, methanol-water as an eluent, non-polar and polar analytes, retention indices, dependence on eluent composition DOI: http://dx.doi.org/10.15826/analitika.2022.26.1.004 Igor G. Zenkevich, Abdennour DerouicheSt. Petersburg State University, Institute for Chemistry, Universitetskii prosp., 26,St. Petersburg 198504, Russian FederationВ результате определения индексов удерживания (RI) 11 органических соединений различной полярности в обращенно-фазовой (ОФ) ВЭЖХ при использовании метанола в составе элюента (С) вычислены коэффициенты зависимости RI(С), т.е. dRI/dС. Формально такие параметры эквивалентны температурным коэффициентам газохроматографических индексов удерживания, b = dRI/dT. Показано, что эти коэффициенты варьируют в широких пределах (в настоящей работе от -2.0 до +4.6), что указывает на необходимость выявления факторов, определяющих их знак и величину. Установлено, что корреляция величин dRI/dС с самими индексами удерживания и со значениями факторов гидрофобности log P (логарифмы коэффициентов распределения в гетерофазной системе 1-октанол/вода), практически отсутствует. Лучше всего коэффициенты dRI/dС коррелируют с такими характеристиками полярности органических соединений, как гомологические инкременты факторов гидрофобности (ilogP) и гомологические инкременты индексов удерживания (iRI). Такие преобразования значений различных свойств А как гомологические инкременты характеризуют разные гомологи вне зависимости от их положения в гомологических рядах, так что величины ilogP и iRI являются характеристиками полярности соответствующих рядов. Подобный подход позволил установить, что зависимость индексов удерживания в ОФ ВЭЖХ от содержания метанола в составе элюента определяется именно полярностью аналитов и их гидрофобно-гидрофильными характеристиками. Для неполярных аналитов типично соотношение dRI/dC 0, тогда как для полярных – dRI/dC 0. Следовательно, определение даже знака этого коэффициента обеспечивает важную информацию о природе аналитов.Ключевые слова: Обращенно-фазовая высокоэффективная жидкостная хроматография, элюент метанол-вода, неполярные и полярные аналиты, индексы удерживания, зависимость индексов от состава элюентаDOI: http://dx.doi.org/10.15826/analitika.2022.26.1.00
ИДЕНТИФИКАЦИЯ НЕИЗВЕСТНОГО КОМПОНЕНТА ЭКСТРАКТА ВОЛОС ЭКСГУМИРОВАННЫХ ЧЕЛОВЕЧЕСКИХ ОСТАНКОВ ПО МАСС-СПЕКТРОМЕТРИЧЕСКИМ И ГАЗОХРОМАТОГРАФИЧЕСКИМ ДАННЫМ
The real example of GC-MS identification of unknown constituent of human hair extract belonging to the exhumed remains is considered. The identification of this constituent (molecular weight 238 Da) was unsuccessful using both its standard mass spectrum (electron ionization) in combination with library search, and its GC retention index value (~1540 on semi-standard non-polar polydimethyl siloxane stationary phases with 5% phenyl groups). However, its identification appeared to be possible using the original algorithm of data processing. This approach implies revealing the structural analogues of unknown analytes, primarily their homologues which differ by molecular masses on ± 14 Da and by composition on CH2 homologous difference. This approach allowed revealing such analogues of unknown analyte as Flavesone (2,2,4,4-tetramethyl-2-isobutyrylcyclohexa-1,3,5-trione), Leptospermone (2,2,4,4-tetramethyl-2-isopentanoylcyclohexa-1,3,5-trione), and some others. All these compounds belong to a rather “exotic” class of natural compounds knows as cyclic b-triketones. Based on the obtained data, the possible structure of the constituent under the consideration was proposed as 2,2,4,4-tetramethyl-2-propionylcyclohexa-1,3,5-trione. The principal feature of cyclic b-triketones is their existence in a few tautomeric forms. Another tautomer of triketone under discussion is 5-hydroxy-2,2,6,6-tetramethyl-4-propionyl-4-en-1,3-dione (CAS № 87552-01-0). This compound is found to be the constituent of Leptospermum scoparium essential oil and some other plants, and it belongs to the group of structural analogues of Flavesone. The most known pharmaceutical application of essential oils containing these compounds are the components of conditioners for hair and skin. The results confirm this formerly unknown component does not belong to the group of toxic substances. This excludes the criminal origin of the remains.Keywords: Human hair extract, unknown constituent, gas chromatography – mass spectrometry, identification, 2,2,4,4-tetrtamethyl-5-propionylcyclohexa-1,3,5-trioneDOI: http://dx.doi.org/10.15826/analitika.2020.25.1.002 Sergei A. Savchuk1, Igor G. Zenkevich2 1Russian center of forensic expertise, Russian Ministry of Health,Polikarpova str., 12/13, Moscow 125284, Russian Federation2St. Petersburg State University, Institute for Chemistry, Universitetskii prosp., 26, St. Petersburg, 198504, Russian Federation Подробно рассмотрен пример хромато-масс-спектрометрической идентификации неизвестного компонента экстракта образца человеческих волос, изъятых у эксгумированных останков. Этот компонент (молекулярная масса 238 Да) не удалось идентифицировать ни в результате библиотечного поиска по стандартному масс-спектру (ионизация электронами), ни по значению газохроматографического индекса удерживания (~1540) на стандартных неполярных полидиметилсилоксановых неподвижных фазах с 5% фенильных групп. Однако его идентификация оказалась возможной с использованием оригинального алгоритма, основанного на выявлении структурных аналогов неизвестных аналитов, прежде всего – их гомологов, различающихся по молекулярным массам на ± 14 Да, а по составу – на гомологическую разность СН2. Этот прием позволил выявить такие аналоги неизвестного соединения как флавесон (2,2,4,4-тетраметил-2-изобутирилциклогекса-1,3,5-трион), лептоспермон (2,2,4,4-тетраметил-2-изопентаноилциклогекса-1,3,5-трион) и ряд других, относящихся к такому достаточно «экзотическому» классу природных соединений как циклические b-трикетоны. На основании полученных данных установлена наиболее вероятная структура “неизвестного” компонента – 2,2,4,4-тетраметил-2-пропионилциклогекса-1,3,5-трион. Отличительной особенностью циклических b-трикетонов является существование в виде нескольких таутомерных форм. В рассматриваемом случае это структура 5-гидрокси-2,2,6,6-тетраметил-4-пропионилциклогекс-4-ен-1,3-диона (CAS № 87552-01-0). Обсуждаемое соединение является компонентов эфирного масла Leptospermum scoparium и некоторых других растений и входит в группу структурных аналогов флавесона. Наиболее известное фармацевтическое применение эфирных масел, содержащих соединения этой группы, – компоненты кондиционеров для волос и кожи головы. Таким образом, установлено, что рассматриваемый компонент не относится к сильнодействующим или токсичным соединениям, что исключает криминальное происхождение останков.Ключевые слова: Экстракт человеческих волос, неизвестный компонент, хромато-масс-спектрометрия, идентификация, 2,2,4,4-тетраметил-5-пропионилциклогексан-1,3,5-трионDOI: http://dx.doi.org/10.15826/analitika.2020.25.1.00
УМЕНЬШЕНИЕ ПОГРЕШНОСТЕЙ ХРОМАТОГРАФИЧЕСКОГО АНАЛИЗА МЕТОДОМ ВНЕШНЕГО СТАНДАРТА И СТАНДАРТНОЙ ДОБАВКИ ЗА СЧЕТ ИСПОЛЬЗОВАНИЯ ДОПОЛНИТЕЛЬНЫХ СТАНДАРТОВ
There are three methods from the known methods of the quantitative chromatographic analysis (external standard, absolute calibration, and standard addition) that are most “sensitive” to the reproducibility of the sample injection. Non-controlled constituents losses of the injected samples lead to the increase of both random and systematic errors of the results. The modifications of external standard and standard addition methods with the use of additional standards were characterized. It is important to note that there are no restrictions on the chemical origin of such standards, so far as they are required for calculation of the relative peak areas only. All calculations were conducted not with absolute, but with relative peak areas. Relative standard deviations of the relative peak areas were 6-38 times less than those of absolute peak areas, which was established in the result of special experiments. This allowed quantitation with the appropriate precision even at the low reproducibility of the injection. The use of histograms for the peak areas was recommended for revealing the losses of samples during injection. However, their application required at least 20 parallel experiments. The equations for calculations, including those for evaluations of values of possible errors, were presented for modified methods of external standard and standard addition supported with additional standards.Keywords: Chromatography, quantification, external standard, standard addition, injection irreproducibility, application of additional standards(Russian)DOI: http://dx.doi.org/10.15826/analitika.2015.19.4.007Igor G. Zenkevich, Denis V. Prokofiev St. Petersburg State University, St. Petersburg, Russian FederationТри из известных методов количественного газохроматографического анализа (внешнего стандарта, абсолютной градуировки и стандартной добавки) в наибольшей степени «чувствительны» к воспроизводимости дозирования проб. Неконтролируемые потери компонентов проб во время этой операции закономерно приводят к увеличению как случайных, так и систематических погрешностей определений. Охарактеризованы модификации методов внешнего стандарта и стандартной добавки, заключающиеся во введении дополнительных стандартов в анализируемые образцы. Важно, что на химическую природу таких стандартов нет никаких ограничений, так как они необходимы только для вычисления относительных площадей пиков. Все вычисления далее проводят не с абсолютными, а с относительными площадями хроматографических пиков. Специальными экспериментами показано, что относительные стандартные отклонения относительных площадей пиков в 6-38 раз меньше, чем значения аналогичных статистических характеристик абсолютных площадей. Это позволяет проводить количественные определения с приемлемой точностью даже в условиях низкой воспроизводимости дозирования. Для выявления потерь проб на стадии дозирования предложено использовать гистограммы распределения площадей хроматографических пиков. Для их построения число параллельных определений должно быть не менее 20. Приведены расчетные соотношения для модифицированных методов внешнего стандарта и стандартной добавки с использованием дополнительных стандартов, в том числе для получения оценок случайных составляющих погрешностей определений.Ключевые слова: Хроматография, количественный анализ, метод внешнего стандарта, метод стандартной добавки, невоспроизводимость дозирования, применение дополнительных стандартов.DOI: http://dx.doi.org/10.15826/analitika.2015.19.4.00