50 research outputs found
Noninvasive Positive Pressure Ventilation against Reperfusion Pulmonary Edema following Percutaneous Transluminal Pulmonary Angioplasty
A 69-year-old man with chronic thromboembolic pulmonary hypertension (CTEPH) was on amblatory oxygen inhalation therapy (3 L/min) and scheduled for percutaneous transluminal pulmonary angioplasty (PTPA). The patient's New York Heart Association functional status was class III with recent worsening of dyspnea and apparent leg edema. Transthoracic echocardiography revealed right ventricular enlargement with mean pulmonary artery pressure of 42 mmHg. After PTPA, he was complicated with postoperative reperfusion pulmonary edema, and noninvasive positive pressure ventilation (NPPV) was applied immediately. Hypoxemia was successfully treated with 15 days of NPPV. Although mean pulmonary artery pressure was unchanged, his brain natriuretic peptide level decreased from preoperative 390.3 to postoperative 44.3 pg/dL. In addition, total pulmonary resistance decreased from preoperative 18 to postoperative 9.6 wood unit·m2. The patient was discharged on day 25 with SpO2 of 95% on 5 L/min of oxygen inhalation. Because pulmonary edema is a postsurgical life-threatening complication following PTPA, application of NPPV should be considered
Shallow-angle needle guide for ultrasound-guided internal jugular venous catheterization: A randomized controlled crossover simulation study (CONSORT).
BackgroundNeedle guides for ultrasound-guided internal jugular venous catheterization facilitate successful cannulation. The ability of a needle guide to prevent a posterior vein wall injury which may secondarily induce lethal complications, is unknown. Previous studies showed that a shallow angle of approach may reduce the incidence of posterior wall injuries. We developed a novel needle guide with a shallow angle of approach for ultrasound-guided venous catheterization and examined whether this needle guide reduces the incidence of posterior wall injuries compared to a conventional needle guide and free-hand placement in a simulated vein.MethodsThis study was a randomized crossover-controlled trial. The primary outcome was the rate of posterior vein wall injuries. Participants had a didactic lecture about three ultrasound-guided techniques using the short-axis out-of-plane approach, including free-hand (P-free), a commercial needle guide (P-com), and a novel needle guide (P-sha). The view inside a simulated vein was recorded during venipuncture.ResultsThirty-five residents participated in this study. Posterior vein wall injuries occurred in 66% using P-free, 60% using P-com, and 0% using P-sha (pConclusionsUse of a shallow angle of approach needle guide resulted in a lower rate of posterior vein injuries during venipuncture of a simulated vein compared with other techniques using a steeper angle techniques
Iatrogenic carpal tunnel syndrome induced by wrist extension for placement of an indwelling radial artery catheter: a case report
Abstract A 38-year-old man with pancreatic cancer was scheduled to undergo pancreaticoduodenectomy. He had an unremarkable past medical history. After inducing general anesthesia, a left radial arterial catheter was successfully placed at first attempt. A wrist splint was used to obtain good arterial pulse waveforms. After the operation, he was transferred to the intensive care unit. The radial artery catheter was removed on the fourth postoperative day. He experienced numbness and a tingling sensation in the left thumb, the second and third fingers, and the lateral half of the fourth finger. He was diagnosed with carpal tunnel syndrome. Diagnostic imaging revealed a swollen median nerve, but no hematoma or injury. Some studies have suggested that excessive extension of the wrist may cause neuropathy. We recommend that patients’ wrists not be over-extended, even if good arterial waveforms cannot be obtained
Inadvertent catheter misplacement into the subclavian artery during ultrasound-guided internal jugular venous catheterization: a case report
Abstract Background Ultrasound-guided central venous catheterization has become a standard procedure. However, mechanical complications are still reported. Case presentation An 85-year-old woman presented with coagulopathic bladder tamponade. Ultrasound-guided right internal jugular venous catheterization was planned because of difficult peripheral venous access. A guidewire was advanced through a needle inserted at the midpoint of the right carotid triangle. The guidewire was identified in the short axis, but not in the long-axis ultrasound view, leading to inadvertent insertion of the catheter into the right subclavian artery through the internal jugular vein. Stent graft insertion was performed for perforation closure. The patient exhibited no symptoms of cerebral ischemia following stent graft insertion. Discussion This case demonstrated that the needle-sticking site should not be placed close to the clavicle for ultrasound-guided internal jugular venous catheterization, as it may not confirm the position of guidewire in the long-axis ultrasound view