87 research outputs found

    Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging

    Get PDF
    Purpose: To determine whether liver function correlating with indocyanine green (ICG) clearance could be estimated quantitatively from gadoxetate disodium-enhanced magnetic resonance (MR) images. Materials and Methods: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. Twenty-three consecutive patients who underwent an ICG clearance test and gadoxetate disodium-enhanced MR imaging with the same parameters as were used for a preoperative examination were chosen. The hepatocellular uptake index (HUI) from liver volume (V(L)) and mean signal intensity of the liver on contrastenhanced T1-weighted images with fat suppression (L(20)) and mean signal intensity of the spleen on contrastenhanced T1-weighted images with fat suppression (S(20)) on 3D gradient-echo T1-weighted images with fat suppression obtained at 20 minutes after gadoxetate disodium (0.025 mmol per kilogram of body weight) administration was determined with the following equation: V(L)[(L(20)/S(20)) 2 1]. The correlation of the plasma disappearance rate of ICG (ICG-PDR) and various factors derived from MR imaging, including HUI, iron and fat deposition in the liver and spleen, and spleen volume (V(S)), were evaluated with stepwise multiple regression analysis. The difference between the ratio of the remnant HUI to the HUI of the total liver (rHUI/HUI) and ratio of the liver remnant V(L) to the total V(L)(rV(L)/V(L)) was evaluated in four patients who had segmental heterogeneity of liver function. Results: HUI and V(S) were the factors significantly correlated with ICG-PDR (R = 0.87). The mean value and its 95% confidence interval were 0.18 and 0.01 to 0.34, respectively, for the following calculation: (rHUI/HUI) 2 (rV(L)/V(L)). Conclusion: The liver function correlating with ICG-PDR can be estimated quantitatively from the signal intensities and the volumes of the liver and spleen on gadoxetate disodium-enhanced MR images, which may improve the estimation of segmental liver function. (C) RSNA, 2011ArticleRADIOLOGY. 260(3):727-733 (2011)journal articl

    Can expiratory or inspiratory contrast-enhanced computed tomography be more efficient for fast-track cannulation of the right adrenal vein in adrenal venous sampling?

    Get PDF
    PURPOSEThis study compares the usefulness of expiratory arterial phase (EAP)–contrast-enhanced computed tomography (CT) (CECT) with that of inspiratory arterial phase (IAP)–CECT in adrenal venous sampling (AVS).METHODSSixty-four patients who underwent AVS and CECT at the authors’ hospital between April 2013 and June 2019 were included in this study. The patients were classified into the following two groups: EAP (32 patients) and IAP (32 patients) groups. The single arterial phase images were obtained at 40 seconds in the IAP group. The double arterial phase images were obtained at 40 seconds in the early arterial phase and 55 seconds in the late arterial phase in the EAP group. The authors then compared the right adrenal vein (RAV) visualization rate on the CECT, the difference between the CECT images and adrenal venograms in the localization of the RAV orifice, the cannulation time to the RAV, and the volume of contrast agent administered intraoperatively between the two groups.RESULTSThe rates of the RAV visualization in the EAP group were 84.4% in the early arterial phase, 93.8% in the late arterial phase, and 100% in the combined early and late arterial phases. The rate of the RAV visualization in the IAP group was 96.9%. There was no significant difference between the two groups in terms of the rate of the RAV visualization. However, there was a small difference in the location of the RAV orifice between the CECT images and adrenal venograms in the EAP group as compared with the IAP group (P < 0.001). The median time to the RAV catheterization was significantly shorter in the EAP group (27.5 minutes) than in the IAP group (35.5 minutes; P = 0.035). The rates of the RAV visualization in the EAP group were not significant between the early arterial phase, late arterial phase, and combined early and late arterial phases (P = 0.066). However, the mean volume CT dose index in the combined early and late arterial phases was significantly higher than in the early and late arterial phases (P < 0.001).CONCLUSIONThe EAP–CECT is more useful for increasing the speed of the RAV cannulation due to the small difference in the localization of the RAV orifice compared to IAP–CECT. However, since EAP–CECT has double contrast arterial phases and increased radiation exposure compared to IAP–CECT, only the late arterial phase may be acceptable to reduce radiation exposure

    Evaluation of hemodynamic imaging findings of hypervascular hepatocellular carcinoma: comparison between dynamic contrast-enhanced magnetic resonance imaging using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction and dynamic computed tomography during hepatic arteriography

    Get PDF
    To compare the visualization of hemodynamic imaging findings of hypervascular hepatocellular carcinoma (HCC) on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction (r-VIBE-KWIC) versus dynamic computed tomography during hepatic arteriography (dyn-CTHA). We retrospectively reviewed the databases of preoperative DCE-MRI using r-VIBE-KWIC, dyn-CTHA, and postoperative pathology of resected specimens. Fourteen patients with 14 hypervascular HCCs underwent both DCE-MRI and dyn-CTHA. The imaging findings of the tumor and adjacent liver parenchyma were assessed on both modalities by two readers. The tumor enhancement time was also compared between the two modalities. On DCE-MRI/dyn-CTHA, early staining, peritumoral low-intensity or low-density bands, corona enhancement, and washout of HCC were observed in 14/14 (100%), 10/12 (83%), 11/14 (78%), and 4/14 (29%) patients, respectively. Pathologically, four HCCs with low-density bands on dyn-CTHA had no fibrous capsules. The median tumor enhancement time on DCE-MRI and dyn-CTHA was 24 (9-24) and 23 (8-35) s, respectively. The correlation coefficient between the two groups was 0.762 (P < 0.002). DCE-MRI using r-VIBE-KWIC has diagnostic potential comparable with that of dyn-CTHA in the hemodynamic evaluation of hypervascular HCC except for the washout phenomenon.ArticleJAPANESE JOURNAL OF RADIOLOGY.36(4):295-302(2018)journal articl

    Effect of cisplatin on cell death and DNA crosslinking in rat mammary. Adenocarcinoma in vitro.

    Get PDF
    The pharmacodynamic effects of cisdiamminedichloroplatinum(II) (CDDP) in vitro have been reported, but the dosage and exposure time in vitro have not been based on clinical observations of the drug's actions in vivo. In this study, the authors attempted to evaluate the pharmacodynamic effects of CDDP in vitro in terms of cell survival and DNA crosslinking by simulating unbound CDDP administration at varying concentrations to a rat mammary adenocarcinoma line (known as line 66). CDDP exposure was conducted by both constant concentration procedures and a simulated in vivo procedure. Colony formation assay for the surviving fraction and alkaline elution assay for DNA crosslink measurement were performed in order to evaluate the pharmacodynamics of CDDP. Cell survival was a function of the area under the drug concentration time curve (AUC) of unbound CDDP (R2 = 0.77, P &#60; 0.002) for all drug exposure procedures as analyzed by the analysis of covariance test. There was a strong correlation between the surviving fraction and the crosslink index of the total amount of DNA crosslinks (R2 = 0.85, P &#60; 0.0005). Both the total amount of DNA-DNA crosslinks and the DNA-protein crosslinks, of which the latter were dominant, were affected not by the exposure procedures, but by the AUC value (P &#60; 0.002). The thresholds of cytocidal effect were 1.59 mg.h/l for the AUC and 0.008 for the crosslink index. The pharmacodynamic effects in vitro by simulated in vivo exposure were identical to those of constant.</p

    Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase

    Get PDF
    To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. aEuro cent Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. aEuro cent Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. aEuro cent Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. aEuro cent Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.ArticleEUROPEAN RADIOLOGY. 24(6):1290-1299 (2014)journal articl

    Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium–enhanced MR Imaging

    Get PDF
    Purpose: To determine whether liver function correlating with indocyanine green (ICG) clearance could be estimated quantitatively from gadoxetate disodium-enhanced magnetic resonance (MR) images. Materials and Methods: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. Twenty-three consecutive patients who underwent an ICG clearance test and gadoxetate disodium-enhanced MR imaging with the same parameters as were used for a preoperative examination were chosen. The hepatocellular uptake index (HUI) from liver volume (V(L)) and mean signal intensity of the liver on contrastenhanced T1-weighted images with fat suppression (L(20)) and mean signal intensity of the spleen on contrastenhanced T1-weighted images with fat suppression (S(20)) on 3D gradient-echo T1-weighted images with fat suppression obtained at 20 minutes after gadoxetate disodium (0.025 mmol per kilogram of body weight) administration was determined with the following equation: V(L)[(L(20)/S(20)) 2 1]. The correlation of the plasma disappearance rate of ICG (ICG-PDR) and various factors derived from MR imaging, including HUI, iron and fat deposition in the liver and spleen, and spleen volume (V(S)), were evaluated with stepwise multiple regression analysis. The difference between the ratio of the remnant HUI to the HUI of the total liver (rHUI/HUI) and ratio of the liver remnant V(L) to the total V(L)(rV(L)/V(L)) was evaluated in four patients who had segmental heterogeneity of liver function. Results: HUI and V(S) were the factors significantly correlated with ICG-PDR (R = 0.87). The mean value and its 95% confidence interval were 0.18 and 0.01 to 0.34, respectively, for the following calculation: (rHUI/HUI) 2 (rV(L)/V(L)). Conclusion: The liver function correlating with ICG-PDR can be estimated quantitatively from the signal intensities and the volumes of the liver and spleen on gadoxetate disodium-enhanced MR images, which may improve the estimation of segmental liver function. (C) RSNA, 2011ArticleRADIOLOGY. 260(3):727-733 (2011)journal articl

    Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase

    Get PDF
    To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. aEuro cent Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. aEuro cent Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. aEuro cent Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. aEuro cent Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.ArticleEUROPEAN RADIOLOGY. 24(6):1290-1299 (2014)journal articl
    corecore