7,516 research outputs found

    Fair Use

    Get PDF

    Orbifold equivalence: structure and new examples

    Full text link
    Orbifold equivalence is a notion of symmetry that does not rely on group actions. Among other applications, it leads to surprising connections between hitherto unrelated singularities. While the concept can be defined in a very general category-theoretic language, we focus on the most explicit setting in terms of matrix factorisations, where orbifold equivalences arise from defects with special properties. Examples are relatively difficult to construct, but we uncover some structural features that distinguish orbifold equivalences -- most notably a finite perturbation expansion. We use those properties to devise a search algorithm, then present some new examples including Arnold singularities.Comment: 34 pages, web-link to Singular code provide

    The eleven antenna: a compact low-profile decade bandwidth dual polarized feed for reflector antennas

    Get PDF
    A novel dual polarized ultrawide-band (UWB) feed with a decade bandwidth is presented for use in both single and dual reflector antennas. The feed has nearly constant beam width and 11 dBi directivity over at least a decade bandwidth. The feed gives an aperture efficiency of the reflector of 66% or better over a decade bandwidth when the subtended angle toward the sub or main reflector is about 53°, and an overall efficiency better than 47% including mismatch. The return loss is better than 5 dB over a decade bandwidth. The calculated results have been verified with measurements on a linearly polarized lab model. The feed has no balun as it is intended to be integrated with an active 180° balun and receiver. The feed is referred to as the Eleven antenna because its basic configuration is two parallel dipoles 0.5 wavelengths apart and because it can be used over more than a decade bandwidth with 11 dBi directivity. We also believe that 11 dB return loss is achievable in the near future

    Design of Cryogenic SiGe Low-Noise Amplifiers

    Get PDF
    This paper describes a method for designing cryogenic silicon-germanium (SiGe) transistor low-noise amplifiers and reports record microwave noise temperature, i.e., 2 K, measured at the module connector interface with a 50-Ω generator. A theory for the relevant noise sources in the transistor is derived from first principles to give the minimum possible noise temperature and optimum generator impedance in terms of dc measured current gain and transconductance. These measured dc quantities are then reported for an IBM SiGe BiCMOS-8HP transistor at temperatures from 295 to 15 K. The measured and modeled noise and gain for both a single- and two-transistor cascode amplifier in the 0.2-3-GHz range are then presented. The noise model is then combined with the transistor equivalent-circuit elements in a circuit simulator and the noise in the frequency range up to 20 GHz is compared with that of a typical InP HEMT

    Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography.

    Get PDF
    The lamina cribrosa (LC) is the presumed site of axonal injury in glaucoma. Its deformation has been suggested to contribute to optic neuropathy by impeding axoplasmic flow within the optic nerve fibers, leading to apoptosis of retinal ganglion cells. To visualize the LC in vivo, optical coherence tomography (OCT) has been applied. Spectral domain (SD)-OCT, used in conjunction with recently introduced enhanced depth imaging (EDI)-OCT, has improved visualization of deeper ocular layers, but in many individuals it is still limited by inadequate resolution, poor image contrast and insufficient depth penetrance. The posterior laminar surface especially is not viewed clearly using these methods. New generation high-penetration (HP)-OCTs, also known as swept-source (SS)-OCT, are capable to evaluate the choroid in vivo to a remarkable level of detail. SS-OCTs use a longer wavelength (1,050 nm instead of 840 nm) compared to the conventional techniques. We review current knowledge of the LC, findings from trials that use SD-OCT and EDI-OCT, and our experience with a prototype SS-OCT to visualize the LC in its entirety. Key Points What is known? •     The LC is the presumed site of axonal injury in glaucoma •     Compared to spectral domain-OCT, enhanced depth imaging-OCT improves imaging of the LC •     Even so, currently used SD-OCT techniques are restricted by poor wavelength penetrance of the deeper ocular layers What our findings add? •    SS-OCT may be a superior imaging modality for deep ocular structures •    Prior studies used SS-OCT to evaluate choroidal thickness in both healthy and 'normal tension glaucoma' eyes •    SS-OCT enables good evaluation of three-dimension (3D) lamina cribrosa morphology. How to cite this article: Nuyen B, Mansouri K, Weinreb RN. Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography. J Current Glau Prac 2012;6(3): 113-119

    Social inequality and HIV-testing

    Get PDF
    The plan to increase HIV testing is a cornerstone of the international health strategy against the HIV/AIDS epidemic, particularly in sub-Saharan Africa. This paper highlights a problematic aspect of that plan: the reliance on clinic- rather than home-based testing. First, drawing on DHS data from across Africa, we demonstrate the substantial differences in socio-demographic and economic profiles between those who report having ever had an HIV test, and those who report never having had one. Then, using data from a random household survey in rural Malawi, we show that substituting home-based for clinic-based testing may eliminate this source of inequality between those tested and those not tested. This result, which is stable across modeling frameworks, has important implications for accurately and equitably addressing the counseling and treatment programs that comprise the international health strategy against AIDS, and that promise to shape the future trajectory of the epidemic in Africa and beyond.AIDS/HIV, home-based testing, inequality, Malawi

    Aqueous Humor Outflow Structure and Function Imaging At the Bench and Bedside: A Review.

    Get PDF
    Anterior segment glaucoma clinical care and research has recently gained new focus because of novel imaging modalities and the advent of angle-based surgical treatments. Traditional investigation drawn to the trabecular meshwork now emphasizes the entire conventional aqueous humor outflow (AHO) pathway from the anterior chamber to the episcleral vein. AHO investigation can be divided into structural and functional assessments using different methods. The historical basis for studying the anterior segment of the eye and AHO in glaucoma is discussed. Structural studies of AHO are reviewed and include traditional pathological approaches to modern tools such as multi-model two-photon microscopy and optical coherence tomography. Functional assessment focuses on visualizing AHO itself through a variety of non-real-time and real-time techniques such as aqueous angiography. Implications of distal outflow resistance and segmental AHO are discussed with an emphasis on melding bench-side research to viable clinical applications. Through the development of an improved structure: function relationship for AHO in the anterior segment of the normal and diseased eye, a better understanding of the eye with improved therapeutics may be developed

    Matched wideband low-noise amplifiers for radio astronomy

    Get PDF
    Two packaged low noise amplifiers for the 0.3–4 GHz frequency range are described. The amplifiers can be operated at temperatures of 300–4 K and achieve noise temperatures in the 5 K range (<0.1 dB noise figure) at 15 K physical temperature. One amplifier utilizes commercially available, plastic-packaged SiGe transistors for first and second stages; the second amplifier is identical except it utilizes an experimental chip transistor as the first stage. Both amplifiers use resistive feedback to provide input reflection coefficient S11<−10 dB over a decade bandwidth with gain over 30 dB. The amplifiers can be used as rf amplifiers in very low noise radio astronomy systems or as i.f. amplifiers following superconducting mixers operating in the millimeter and submillimeter frequency range

    Hotspots and Coldspots: Household and village-level variation in orphanhood prevalence in rural Malawi

    Get PDF
    We explore the spatial distribution of orphans in two areas of Malawi. We first review pertinent themes in qualitative data collected in our research sites. Then, using spatial analysis, we show how positive and negative clusters of orphans—which we term orphanhood "hotspots" and "coldspots"—can be found at the village and sub-village levels. In the third and longest section of the paper, and using multilevel analyses with both simple and complex variance structures, we evaluate the relationship between the presence of orphans and a range of individual, household and village-level characteristics, including households' spatial relationship to each other and to other local sites of significance. This series of analyses shows that the most important covariates of orphan presence are the density of settlement, household size, and religious characteristics, with the latter measured simultaneously at both household and village-level. Other characteristics like education, reported mortality levels and HIV infection, are wholly unrelated to orphan prevalence at all analytic levels. Wealth and various spatial characteristics are only marginally associated with orphan prevalence. We conclude by reviewing some difficulties in explaining causal mechanisms underlying these observed relationships, and discussing conceptual, theoretical and programmatic implications.Africa, AIDS/HIV, Malawi, multilevel model, orphan prevalence, orphans, spatial analysis

    Adapting to Adaptation: Turning YA Literature into Television

    Get PDF
    I have always loved film and television, whether for casual consumption or academic pursuits. Throughout my time as an English and American Studies double major (and almost a Media and Film Studies minor), I have opted to study film and TV at every chance I could. In my junior year I began writing my own film, and I completed that film in the first half of senior year. When entering my final year of the English major and faced with making a decision surrounding my capstone, I was simultaneously deciding whether or not to pursue graduate studies in screenwriting. As I realized that my current career goal is to become a published screenwriter, I decided that I wanted to tackle a project that had been lying dormant in my head for years; adapting one of my favorite YA novels, Gone by Michael Grant, into a television show. This book was a major formative moment in my childhood, with its many intersectional representations that marked my first encounters with queerness, racial differences, and disability. On top of the positive social messages that the story promotes, the visual description in the book is immaculate, and makes translating it for the screen an easier challenge (but a challenge nonetheless). I was not only interested in the creative piece, however, as my academic career at Skidmore has always involved research. I also wanted to look at studies on adaptation, and discover what the implications of adaptation often are. Ultimately, I settled on pursuing a televisual adaptation of Gone because it synthesized all the different aspects of my academic career that I enjoy and am passionate about, as well as my career goals for the future
    corecore