219 research outputs found

    AN APPROACH TO EXAMINE THE EFFECT OF TAPER ANGLE AND THREADING ON PERIPROSTHETIC BONE REMODELING FROM BONE-ANCHORED AMPUTATION PROSTHESES

    Get PDF
    INTRODUCTION The most common problems experienced by transfemoral amputees using socket prostheses are soft tissue pain and a limited range of motion around the hip joint [1].  Recently, intraosseous transcutaneous amputation prostheses (ITAP) have been developed as an alternative to the standard socket prostheses for amputees.  A current shortcoming of ITAP is the change in the local mechanical loading at the bone-implant interface leading to bone resorption.  The clinical consequences of this bone loss are increased risks of bone fracture and implant loosening [2].  The purpose of this study was to develop a finite element modeling approach to examine the effect of ITAP fixture threading and taper angle on femoral bone remodeling. METHODS An intact femoral geometry was generated using Mimics software (Materialise, Leuven, Belgium) from CT scans obtained from the VAHKUM database [3]. Twelve ITAP (six threaded and six unthreaded) implants of varying taper angles were designed using SolidWorks (Waltham, MA). Implants were registered and aligned within the femoral diaphysis, and the implant-femur assembly was meshed with quadratic tetrahedral elements; elements at the bone-implant interface shared identical nodes to represent full osseointegration.  Bone elements were assigned inhomogeneous linear-elastic material properties based on CT Hounsfield units. Implant material was modeled as titanium alloy Ti6Al4V (E=114 GPa, ν=0.3), which is commonly used for prostheses due to its superior strength and biocompatibility. Boundary conditions and loads applied to the finite element models were taken from Tomaszewski et al. [4], which were linearly scaled to correspond to an individual with a mass of 70.1 kg and a height of 170 cm.  All models were solved using ABAQUS Standard v6.1 (Providence, RI). Strain energy density was calculated for each implanted femur and compared to those of an intact femur. RESULTS Considerable energy was transferred to the ITAP (Figure 1). Consequently, the periprosthetic cortical bone in the implanted femur had a significantly lower strain energy density than that of the intact femur (Figure 1). DISCUSSION AND CONCLUSIONS It is critical that implant geometry is optimized to decrease periprosthetic bone resorption and reduce the incidence of bone fracture and implant loosening.  Changes in strain energy density following prosthetic implantation is a driving stimulus for bone remodeling, and our future work will incorporate adaptive bone remodeling algorithms into our simulations

    THE INFLUENCE OF EFFECTIVE MASS ON IMPACT FORCE AND ACCELERATION

    Get PDF
    Accelerometry is often used as a means to quantify the osteogenic or injury potential of impacts. This paper uses a series of four experiments to demonstrate theoretically, mechanically, and experimentally that increasing the effective mass of an impact can lead to an increase in impact force with a corresponding decrease in acceleration. The four experiments included: 1) mass spring models, 2) shoe impact testing, 3) cadaver impact simulation, and 4) an in vivo study manipulating knee angle during running. Results were consistent with the aim, illustrating a limitation for the use of accelerometers for impact assessment. In order to appropriately interpret the results from accelerometry it is necessary to quantify the effective mass of the impact. Failure to account for the influence of effective mass can lead to erroneous conclusions about impact severity

    Characterizing the Hydrology of Shallow Floodplain Lakes in the Slave River Delta, NWT, Canada, Using Water Isotope Tracers

    Get PDF
    The relative importance of major hydrological processes on thaw season 2003 lakewater balances in the Slave River Delta, NWT, Canada, is characterized using water isotope tracers and total suspended sediment (TSS) analyses. A suite of 41 lakes from three previously recognized biogeographical zones—outer delta, mid-delta, and apex—were sampled immediately following the spring melt, during summer, and in the fall of 2003. Oxygen and hydrogen isotope compositions were evaluated in the context of an isotopic framework calculated from 2003 hydroclimatic data. Our analysis reveals that flooding from the Slave River and Great Slave Lake dominated early spring lakewater balances in outer and most mid-delta lakes, as also indicated by elevated TSS concentrations (\u3e0.01 g L-1). In contrast, the input of snowmelt was strongest on all apex and some mid-delta lakes. After the spring melt, all delta lakes underwent heavy-isotope enrichment due to evaporation, although lakes flooded by the Slave River and Great Slave Lake during the spring freshet continued to be more depleted isotopically than those dominated by snowmelt input. The isotopic signatures of lakes with direct connections to the Slave River or Great Slave Lake varied throughout the season in response to the nature of the connection. Our findings provide the basis for identifying three groups of lakes based on the major factors that control their water balances: (1) flood-dominated (n=10), (2) evaporation-dominated (n=25), and (3) exchange-dominated (n=6) lakes. Differentiation of the hydrological processes that influence Slave River Delta lakewater balances is essential for ongoing hydroecological and paleohydrological studies, and ultimately, for teasing apart the relative influences of variations in local climate and Slave River hydrology

    Climate-driven Shifts in Quantity and Seasonality of River Discharge over the past 1000 Years from the Hydrographic Apex of North America

    Get PDF
    Runoff generated from high elevations is the primary source of freshwater for western North America, yet this critical resource is managed on the basis of short instrumental records that capture an insufficient range of climatic conditions. Here we probe the effects of climate change over the past ~1000 years on river discharge in the upper Mackenzie River system based on paleoenvironmental information from the Peace-Athabasca Delta. The delta landscape responds to hydroclimatic changes with marked variability, while Lake Athabasca level appears to directly monitor overall water availability. The latter fluctuated systematically over the past millennium, with the highest levels occurring in concert with maximum glacier extent during the Little Ice Age, and the lowest during the 11th century, prior to medieval glacier expansion. Recent climate-driven hydrological change appears to be on a trajectory to even lower levels as high-elevation snow and glacier meltwater contributions both continue to decline

    Tibial Strains are Sensitive to Speed, but not Grade, Perturbations During Running

    Full text link
    Tibial stress fractures are thought to result from a fatigue-failure process where bone failure is highly dependent on peak strain magnitude. Little is known regarding the mechanical loading environment of the tibia during graded running despite the prevalence of this terrain. To probe the sensitivity of the mechanical loading environment of the tibia to running grade, tibial strains were quantified using a combined musculoskeletal-finite element modeling routine during graded and level running. Seventeen participants ran on a treadmill at ±\pm10{\deg}, ±\pm5{\deg}, and 0{\deg} while force and motion data were captured. At each grade, participants ran at 3.33 m/s and a grade-adjusted speed, that was 2.20 m/s and 4.17 m/s for uphill and downhill conditions, respectively. Muscle and joint contact forces were estimated using inverse-dynamics-based static optimization. These forces were applied to a participant-informed finite element model of the tibia. 50th percentile pressure-modified von Mises strain was lower (≤\leq-130 με\mu\varepsilon) during downhill running compared to level and uphill running at 3.33 m/s. However, neither 95th percentile strain (peak strain) nor the volume of bone experiencing strains ≥\geq4000 με\mu\varepsilon (strained volume) were different between grades (F(4)≤\leq3.28, p≥\geq0.01). In contrast, peak strain and strained volume were highly sensitive to running speed (F(1)≥\geq10.61, p≤\leq0.001), where a 1 m/s increase in speed resulting in a 9 % and 155 % increase in peak strain and strained volume, respectively. Overall, these findings suggest that faster running speeds, but not changes in running grade, may increase the risk of developing a tibial stress fracture

    On the statistics of binned neural point processes: the Bernoulli approximation and AR representation of the PST histogram

    Full text link
    Neural point processes are often approximated by partitioning time into bins, each with a Bernoulli distribution of firing, in order to simplify the mathematical description of their properties. Some of the basic statistics of a neural process are compared using the Bernoulli approximation and the actual Poisson representation. It is seen that in general the Bernoulli approximation is an accurate model only for small λΔ where λ is the intensity and Δ is the width of the time bin. This discrete representation leads to a model of the PST histogram as an AR system, where the parameters depend upon the driving signal s(t) , the refractory effect r(t) and the binwidth Δ . This AR representation is used to predict the PST histogram given s(t) , r(t) and Δ . Estimates of s(t) and r(t) are derived within this parameterization and results discussed for several types of recovery functions given a constant s(t) . AR techniques are used to estimate the AR parameters from the PST histogram of a simulated point process, from which both s(t) and r(t) are estimated.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47434/1/422_2004_Article_BF02331344.pd

    Effects of Stride Length and Running Mileage on a Probabilistic Stress Fracture Model

    Get PDF
    The fatigue life of bone is inversely related to strain magnitude. Decreasing stride length is a potential mechanism of strain reduction during running. If stride length is decreased, the number of loading cycles will increase for a given mileage. It is unclear if increased loading cycles are detrimental to skeletal health despite reductions in strain. Purpose: To determine the effects of stride length and running mileage on the probability of tibial stress fracture. Methods: Ten male subjects ran overground at their preferred running velocity during two conditions: preferred stride length and 10% reduction in preferred stride length. Force platform and kinematic data were collected concurrently. A combination of experimental and musculoskeletal modeling techniques was used to determine joint contact forces acting on the distal tibia. Peak instantaneous joint contact forces served as inputs to a finite element model to estimate tibial strains during stance. Stress fracture probability for stride length conditions and three running mileages (3, 5, and 7 miles·d−1) were determined using a probabilistic model of bone damage, repair, and adaptation. Differences in stress fracture probability were compared between conditions using a 2 × 3 repeated-measures ANOVA. Results: The main effects of stride length (P = 0.017) and running mileage (P = 0.001) were significant. Reducing stride length decreased the probability of stress fracture by 3% to 6%. Increasing running mileage increased the probability of stress fracture by 4% to 10%. Conclusions: Results suggest that strain magnitude plays a more important role in stress fracture development than the total number of loading cycles. Runners wishing to decrease their probability for tibial stress fracture may benefit from a 10% reduction in stride length
    • …
    corecore