62 research outputs found

    Personality traits, ventricular tachyarrhythmias, and mortality in patients with an implantable cardioverter defibrillator: 6 years follow-up of the WEBCARE cohort

    Get PDF
    Objective: Risk stratification within the ICD population warrants the examining of the role of protective- and risk factors. Current study examines the association between Type D personality, pessimism, and optimism and risk of ventricular tachyarrhythmias (VTa's) and mortality in patients with a first-time ICD 6 years post implantation. Methods: A total of 221 first-implant ICD patients completed questionnaires on optimism and pessimism (Life Orientation Test) and Type D personality (Type D scale DS14) 10 to 14 days after implantation. VTa's and all-cause mortality 6 years post implant comprised the study endpoints. Results: Ninety (40.7%) patients had experienced VTa's and 37 (16.7%) patients died, 12 (5.4%) due to a cardiac cause. Adjusted logistic regression analysis showed that pessimism was significantly associated with increased risk of VTa's (OR = 1.09; 95% CI = 1.00–1.19; p =.05). Type D personality (OR = 1.05; 95% CI = 0.47–2.32; p =.91) and optimism (OR = 1.00; 95% CI = 0.90–1.12; p =.98) were not associated with VTa's. None of the personality types were associated with mortality. Conclusion: Pessimism was associated with VTa's but not with mortality. No significant association with either of the endpoints was observed for Type D personality and optimism. Future research should focus on the coexistent psychosocial factors that possibly lead to adverse cardiac prognosis in this patient population

    Focal salvage treatment for radiorecurrent prostate cancer: A magnetic resonance-guided stereotactic body radiotherapy versus high-dose-rate brachytherapy planning study

    Get PDF
    Background and Purpose: Magnetic resonance imaging (MRI)-guided focal salvage high-dose-rate brachytherapy (FS-HDR-BT) is one of the treatment options for radiorecurrent localized prostate cancer. However, due to the invasive nature of the treatment, not all patients are eligible. Magnetic resonance linear accelerator (MR-Linac) systems open up new treatment possibilities and could potentially replace FS-HDR-BT treatment. We conducted a planning study to investigate the feasibility of delivering a single 19 Gy dose to the recurrent lesion using a 1.5 Tesla MR-Linac system. Materials and Methods: Thirty patients who underwent FS-HDR-BT were included. The clinical target volume (CTV) encompassed the visible lesion plus a 5 mm margin. Treatment plans were created for a 1.5 Tesla MR-Linac system using a 1 mm planning target volume (PTV) margin. A dose of 19 Gy was prescribed to ≥ 95% of the PTV. In case this target could not be reached, i.e. when organs-at-risk (OAR) constraints were violated, a dose of ≥ 17 Gy to ≥ 90% of the PTV was accepted. MR-Linac plans were compared to clinical FS-HDR-BT plans. Results: Target dose coverage was achieved in 14/30 (47%) FS-HDR-BT plans and 17/30 (57%) MR-Linac plans, with comparable median D95% and D90%. In FS-HDR-BT plans, a larger volume reached ≥ 150% of the prescribed dose. Urethra D10%, rectum D1cm3, and rectum D2cm3 were lower in the FS-HDR-BT plans, while bladder dose was comparable for both modalities. Conclusion: Single fraction treatment of recurrent prostate cancer lesions may be feasible using stereotactic body radiotherapy (SBRT) on a MR-Linac system

    On-line daily plan optimization combined with a virtual couch shift procedure to address intrafraction motion in prostate magnetic resonance guided radiotherapy

    Get PDF
    Background and purpose: In daily adaptive magnetic resonance (MR)-guided radiotherapy, plans are adapted based on the patient's daily anatomy. During this adaptation phase, prostate intrafraction motion (IM) can occur. The aim of this study was to investigate the efficacy of always applying a subsequent virtual couch shift (VCS) to counter IM that occurred during the daily contour and plan adaption (CPa) procedure. Material and Methods: One hundred fifty patients with low and intermediate risk prostate cancer were treated with 5x7.25 Gy fractions on a 1.5 T MR-Linac. In each fraction, contour adaptation and dose re-optimization was performed using the session's first MR-scan. IM that occurred here was countered using two methods. One patient group had selective VCS (sVCS) applied if the CTV reached outside the PTV on a second MR acquired during plan optimization. The other group had always VCS (aVCS) applied for any prostate shift greater than 1 mm. Remaining IM during beam delivery was determined using 3D cine-MR. Results: Percentage of fractions where a VCS was applied was 28% (sVCS) vs 78% (aVCS). Always applying VCS significantly reduced influences of systematic prostate IM. Population random and systematic median values in all translations directions were lower for the aVCS than sVCS group, but not for the population random cranial-caudal direction. Conclusion: Applying VCS after daily CPa reduced impact of systematic prostate drift in especially the posterior and caudal translation direction. However, due to the continuous and stochastical nature of prostate IM, margin reduction below 4 mm requires fast intrafraction plan adaption methods

    Accumulated bladder wall dose is correlated with patient-reported acute urinary toxicity in prostate cancer patients treated with stereotactic, daily adaptive MR-guided radiotherapy

    Get PDF
    Background and purpose: Magnetic resonance (MR)-guided linear accelerators (MR-Linac) enable accurate estimation of delivered doses through dose accumulation using daily MR images and treatment plans. We aimed to assess the association between the accumulated bladder (wall) dose and patient-reported acute urinary toxicity in prostate cancer (PCa) patients treated with stereotactic body radiation therapy (SBRT). Materials and methods: One-hundred-and-thirty PCa patients treated on a 1.5 T MR-Linac were included. Patients filled out International Prostate Symptom Scores (IPSS) questionnaires at baseline, 1 month, and 3 months post-treatment. Deformable image registration-based dose accumulation was performed to reconstruct the delivered dose. Dose parameters for both bladder and bladder wall were correlated with a clinically relevant increase in IPSS (≥ 10 points) and/or start of alpha-blockers within 3 months using logistic regression. Results: Thirty-nine patients (30%) experienced a clinically relevant IPSS increase and/or started with alpha-blockers. Bladder D5cm3, V10–35Gy (in %), and Dmean and Bladder wall V10–35Gy (cm3 and %) and Dmean were correlated with the outcome (odds ratios 1.04–1.33, p-values 0.001–0.044). Corrected for baseline characteristics, bladder V10–35Gy (in %) and Dmean and bladder wall V10–35Gy (cm3 and %) and Dmean were still correlated with the outcome (odds ratios 1.04–1.30, p-values 0.001–0.028). Bladder wall parameters generally showed larger AUC values. Conclusion: This is the first study to assess the correlation between accumulated bladder wall dose and patient-reported urinary toxicity in PCa patients treated with MR-guided SBRT. The dose to the bladder wall is a promising parameter for prediction of patient-reported urinary toxicity and therefore warrants prospective validation and consideration in treatment planning

    Small-scale solar magnetic fields

    Get PDF
    As we resolve ever smaller structures in the solar atmosphere, it has become clear that magnetism is an important component of those small structures. Small-scale magnetism holds the key to many poorly understood facets of solar magnetism on all scales, such as the existence of a local dynamo, chromospheric heating, and flux emergence, to name a few. Here, we review our knowledge of small-scale photospheric fields, with particular emphasis on quiet-sun field, and discuss the implications of several results obtained recently using new instruments, as well as future prospects in this field of research.Comment: 43 pages, 18 figure

    Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5T MR-Linac

    Get PDF
    Purpose: To evaluate prostate intrafraction motion using MRI during the full course of online adaptive MR-Linac radiotherapy (RT) fractions, in preparation of MR-guided extremely hypofractionated RT. Material and methods: Five low and intermediate risk prostate cancer patients were treated with 20 × 3.1 Gy fractions on a 1.5T MR-Linac. Each fraction, initial MRI (Pre) scans were obtained at the start of every treatment session. Pre-treatment planning MRI contours were propagated and adapted to this Pre scan after which plan re-optimization was started in the treatment planning system followed by dose delivery. 3D Cine-MR imaging was started simultaneously with beam-on and acquired over the full beam-on period. Prostate intrafraction motion in this cine-MR was determined with a previously validated soft-tissue contrast based tracking algorithm. In addition, absolute accuracy of the method was determined using a 4D phantom. Results: Prostate motion was completely automatically determined over the full on-couch period (approx. 45 min) with no identified mis-registrations. The translation 95% confidence intervals are within clinically applied margins of 5 mm, and plan adaption for intrafraction motion was required in only 4 out of 100 fractions. Conclusion: This is the first study to investigate prostate intrafraction motions during entire MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and prostate tracking during RT is feasible with beam-on. The clinically applied margins of 5 mm have proven to be sufficient for these treatments and may potentially be further reduced using intrafraction plan adaptation guided by cine-MR imaging

    Delivered dose quantification in prostate radiotherapy using online 3D cine imaging and treatment log files on a combined 1.5T magnetic resonance imaging and linear accelerator system

    Get PDF
    Background and purpose: Monitoring the intrafraction motion and its impact on the planned dose distribution is of crucial importance in radiotherapy. In this work we quantify the delivered dose for the first prostate patients treated on a combined 1.5T Magnetic Resonance Imaging (MRI) and linear accelerator system in our clinic based on online 3D cine-MR and treatment log files. Materials and methods: A prostate intrafraction motion trace was obtained with a soft-tissue based rigid registration method with six degrees of freedom from 3D cine-MR dynamics with a temporal resolution of 8.5–16.9 s. For each fraction, all dynamics were also registered to the daily MR image used during the online treatment planning, enabling the mapping to this reference point. Moreover, each fraction's treatment log file was used to extract the timestamped machine parameters during delivery and assign it to the appropriate dynamic volume. These partial plans to dynamic volume combinations were calculated and summed to yield the delivered fraction dose. The planned and delivered dose distributions were compared among all patients for a total of 100 fractions. Results: The clinical target volume underwent on average a decrease of 2.2% ± 2.9% in terms of D99% coverage while bladder V62Gy was increased by 1.6% ± 2.3% and rectum V62Gy decreased by 0.2% ± 2.2%. Conclusions: The first MR-linac dose reconstruction results based on prostate tracking from intrafraction 3D cine-MR and treatment log files are presented. Such a pipeline is essential for online adaptation especially as we progress to MRI-guided extremely hypofractionated treatments

    Robotic MR-guided high dose rate brachytherapy needle implantation in the prostate (ROBiNSon)—a proof-of-concept study

    Get PDF
    Objective. A robotic needle implant device for MR-guided high-dose-rate (HDR) prostate brachytherapy was developed. This study aimed to assess the feasibility and spatial accuracy of HDR brachytherapy using the robotic device, for a single intraprostatic target point. Approach. Five patients were treated from November 2019-June 2022 with the robot. The robot fits a 1.5 T MR scanner and the needle can be shifted and angulated. An intraprocedural MR scan was fused with the diagnostic MR and one preplanned needle position was selected for robotic insertion. The needle entry point and angles were set for a needle tip target point within the intraprostatic target volume. The needle was tapped stepwise towards the target point pneumatically. Final needle position was verified with MR, followed by plan optimization and dose delivery. Any remaining planned needles were inserted manually. Needle tip to geometrical target error (NTG-error) was defined as the deviation of the actual tip position relative to the predefined geometric target point, using MR-coordinates. Needle tip to treatment target error (NTT-error) was defined as the deviation of the actual tip position relative to the treatment target point, using fused MR-images pre- and post-needle implantation taking into account prostate deformation. Difference between NTT-error and NTG-error and fiducial marker shifts indicated prostate movement. For determining prostate deformation, the Jaccard index and prostate volumes were assessed. Main results. The robotic device was able to tap the needle to the planned depth for all patients. Mean robotic procedure duration was 142 min. NTG-error was 3.2 (range 1.1-6.7) mm and NTT-error 4.5 (range 2.6-9.6) mm. Marker displacements were smaller than 3 mm. No treatment-related acute toxicity was reported. Feasibility of needle placement within the prostate was considered adequate. Significance. MR-guided robotic needle insertion is feasible with a mean geometric accuracy of 3.2 mm and <3 mm prostate movement

    Effect of Austenite Deformation on the Microstructure Evolution and Grain Refinement Under Accelerated Cooling Conditions

    Get PDF
    Although there has been much research regarding the effect of austenite deformation on accelerated cooled microstructures in microalloyed steels, there is still a lack of accurate data on boundary densities and effective grain sizes. Previous results observed from optical micrographs are not accurate enough, because, for displacive transformation products, a substantial part of the boundaries have disorientation angles below 15 deg. Therefore, in this research, a niobium microalloyed steel was used and electron backscattering diffraction mappings were performed on all of the transformed microstructures to obtain accurate results on boundary densities and grain refinement. It was found that with strain rising from 0 to 0.5, a transition from bainitic ferrite to acicular ferrite occurs and the effective grain size reduces from 5.7 to 3.1 μm. When further increasing strain from 0.5 to 0.7, dynamic recrystallization was triggered and postdynamic softening occurred during the accelerated cooling, leading to an inhomogeneous and coarse transformed microstructure. In the entire strain range, the density changes of boundaries with different disorientation angles are distinct, due to different boundary formation mechanisms. Finally, the controversial influence of austenite deformation on effective grain size of low-temperature transformation products was argued to be related to the differences in transformation conditions and final microstructures
    • …
    corecore