22 research outputs found

    New membranes based on polyethersulfone – SlipSkin™ polymer blends with low fouling and high blood compatibility

    Get PDF
    Hemodialysis is an important therapy for treating patients with End Stage Renal Disease (ESRD). These patients visit the hospital 3 times a week and each time their blood is cleansed during 4-hour dialysis sessions using a hollow fiber membrane module; also called artificial kidney. This device mainly achieves removal of small water-soluble toxins and a limited number of middle molecules. To improve the clearance of toxins, especially middle molecules and protein bound toxins, longer treatment via nocturnal dialysis and/or the application of portable/wearable artificial kidney is required. Such therapies require application of membranes with very low fouling and very good blood compatibility. Current membranes often contain hydrophilic additives which could elute during sterilization processes and/or during long-term filtration. In this study, we propose a simple method for developing low fouling blood compatible membranes by blending of polyethersulfone (PES), a material already used for fabrication of dialysis membranes, with small amounts of SlipSkin™ (SS), a blood compatible random copolymer of hydrophilic N-vinylpyrrolidone (NVP) and hydrophobic N-butylmethacrylate (BMA). Our results show that membranes with 2 wt% of SS have high fouling resistance to proteins and middle-size molecules and very good blood compatibility, making these membranes promising for application in dialysis therapy

    Platelet Aggregation in Healthy Participants is Not Affected by Smoking, Drinking Coffee, Consuming a High-Fat Meal, or Performing Physical Exercise

    No full text
    Platelet aggregation can be measured using optical aggregation (light transmission aggregometry, LTA) as well as by impedance (Multiplate analyzer). The LTA (the gold standard method) can be influenced by many preanalytical variables. Several guidelines differ in recommendations for the duration patients should refrain from smoking, coffee, fatty meals, and physical exercise prior to blood collection for performing platelet function tests. In this pilot study, the influence of smoking, coffee, high-fat meal, or physical exercise on platelet aggregation was investigated to improve patient friendliness and laboratory logistics in platelet function diagnostics. Standardized blood collection was performed when participants were fasting and after each parameter (n=5 per group). As a control for diurnal fluctuations, participants (n=6) were fasting during both blood collections. Platelet aggregation was executed using standardized methods for LTA and Multiplate analyzer. Statistical analysis of the results using Wilcoxon signed-rank test did not show any significant differences in platelet aggregation in healthy participants under different preanalytical variables. Therefore, these variables are not expected to adversely affect testing, which can avoid canceling tests for those patients who inevitably did.</p

    Heterophilic antibodies leading to falsely positive D-dimer concentration in an adolescent

    No full text
    BACKGROUND: We present the case of a 15-year-old adolescent with suspected pulmonary embolism and repeatedly elevated D-dimer levels. KEY CLINICAL QUESTION: We aim to determine the cause for elevated D-dimer levels in a patient without venous thromboembolism. CLINICAL APPROACH: When the D-dimer measurement was repeated with different assays, D-dimer levels were within the normal reference interval. Dilution series with assay diluent or low-affinity antibody blocking reagents either did not or only partially decreased the D-dimer value using the original reagent kit. CONCLUSION: Analyses suggested the presence of interfering heterophilic antibodies in patient plasma, a known phenomenon with immunoturbidimetric D-dimer assays, which is rarely described. Prior to drawing this conclusion, the patient underwent extensive diagnostic testing, which led to uncertainty and discomfort for the health care providers, the patient, and their family

    Fibrinolysis in patients with chemotherapy-induced thrombocytopenia and the effect of platelet transfusion

    No full text
    EssentialsBleeding in chemotherapy induced thrombocytopenia (CIT) might be influenced by hyperfibrinolysis. t-PA-thromboelastography is a fast and reliable assay for hyperfibrinolysis in CIT patients. Clots of CIT patients are more susceptible to t-PA induced lysis compared to healthy individuals. Besides platelets, other factors are likely to influence clot lysis in CIT patients. Background Bleeding events in chemotherapy-induced thrombocytopenic (CIT) patients with similar platelet counts might be influenced by changes in clot lysis potential. Objectives To investigate, in an observational study, thromboelastographic lysis parameters, alterations in clot strength and susceptibility to clot lysis in CIT patients. To identify factors associated with fibrinolytic profiles, and to evaluate the effects of platelet transfusions. Methods Independent determinants of tissue-type plasminogen activator (t-PA)-ROTEM lysis parameters were identified with multivariable linear regression. Clot formation, strength and lysis parameters were compared with the results of healthy individuals. Characteristics of CIT patients with and without hyperfibrinolytic profiles were compared. t-PA-ROTEM results before, 1 hour after and 24 hours after platelet transfusion were compared. Results A total of 72 consecutive CIT patients were included. t-PA-ROTEM lysis parameters correlated with changes in fibrinolytic proteins. Clot formation time was longer, maximum clot firmness was weaker and lysis times were shorter than in healthy individuals. CIT patients had low plasminogen activator inhibitor-1 and thrombin-activatable fibrinolysis inhibitor levels, and 40% showed hyperfibrinolytic profiles. Platelet transfusions resulted in less hyperfibrinolytic profiles in many, but not all CIT patients. Patients without hyperfibrinolytic profiles had higher fibrinogen, factor VIII and alpha(2)-antiplasmin levels. Conclusions t-PA-ROTEM can be used as a fast and reliable assay to detect hyperfibrinolytic profiles in CIT patients. CIT patients have weaker clots, which are more susceptible to clot lysis, than healthy individuals. Besides platelets, other factors are likely to influence clot susceptibility to fibrinolysis in CIT patients. The impact of a hyperfibrinolytic t-PA-ROTEM profile on bleeding remains to be investigated.</p

    Rotational Thromboelastometry in High-Risk Patients on Dual Antithrombotic Therapy After Percutaneous Coronary Intervention

    No full text
    Aims: Patients using antithrombotic drugs after percutaneous coronary intervention (PCI) are at risk for bleeding and recurrent ischemia. We aimed to explore routine and tissue plasminogen activated (tPA) ROTEM results in a post-PCI population on dual antithrombotic treatment. Methods and Results: In this prospective cohort, 440 patients treated with double antithrombotic therapy after recent PCI and with ≥3 risk factors for either ischemic or bleeding complications were included and compared with a control group (n = 95) consisting of perioperative patients not using antithrombotic medication. Laboratory assessment, including (tPA) ROTEM, was performed one month post-PCI and bleeding/ischemic complications were collected over a five-month follow-up. Patients were stratified by antithrombotic regimen consisting of a P2Y12 inhibitor with either aspirin (dual antiplatelet therapy; DAPT, n = 323), a vitamin K antagonist (VKA, n = 69) or a direct oral anticoagulant (DOAC, n = 48). All post-PCI patients had elevated ROTEM clot stiffness values, but only the DAPT group additionally presented with a decreased fibrinolytic potential as measured with tPA ROTEM. Patients receiving anticoagulants had prolonged clotting times (CT) when compared to the control and DAPT group; EXTEM and FIBTEM CT could best discriminate between patients (not) using anticoagulants (AUC > 0.97). Furthermore, EXTEM CT was significantly prolonged in DAPT patients with bleeding complications during follow-up (68 [62–70] vs. 62 [57–68], p = 0.030). Conclusion: ROTEM CT has high potential for identifying anticoagulants and tPA ROTEM could detect a diminished fibrinolytic potential in patients using DAPT. Furthermore, the ability of EXTEM CT to identify patients at risk for bleeding may be promising and warrants further research

    Detecting clinically relevant rivaroxaban or dabigatran levels by routine coagulation tests or thromboelastography in a cohort of patients with atrial fibrillation

    No full text
    Abstract Background Traditional coagulation tests are included in emergency guidelines for management of patients on direct oral anticoagulants (DOACs) who experience acute bleeding or require surgery. We determined the ability of traditional coagulation tests and fast whole blood thromboelastography (ROTEM®) to screen for anticoagulation activity of dabigatran and rivaroxaban as low as 30 ng/mL. Methods One hundred eighty-four citrated blood samples (75 dabigatran, 109 rivaroxaban) were collected from patients with non-valvular atrial fibrillation (NVAF), to perform screening tests from different manufacturers, (diluted, D) PT, aPTT, TT and ROTEM®. The activity of DOACs was quantitatively determined by clot detection assays: Hemoclot DTT and DiXaI test (Biophen), on CS2100 (Siemens). The clotting time (CT) of INTEM and EXTEM ROTEM® (Werfen) were used as test parameters. Results Dabigatran, ≥ 30 ng/mL, was accurately detected by five coagulation tests: APTT Actin FSL (93%), PT Neoplastin (93%), APTT Cephascreen, Thromboclotin, and Thrombin (all 100%), but not by PT Innovin (49%). CT-EXTEM (91%) was sufficiently sensitive, but not CT-INTEM (52%). APTT Cephascreen and Thrombin showed good linearity (R2 = 0.71,R2 = 0.72). For the other tests linearity was moderate to poor. Rivaroxaban was accurately detected by PT Neoplastin (98%) and less so by APTT Cephascreen (85%). In addition, rivaroxaban was also accurately detected by CT-INTEM (96%). PT Neoplastin showed good linearity (R2 = 0.81), all other tests had moderate to poor linearity. Conclusion In patients with NVAF, the ability of routine coagulation tests to detect the presence of significant levels of DOACs is test and reagent dependent. CT-INTEM and CT-EXTEM may be fast whole blood alternatives. Trial registration The Institutional Review Board of the MUMC approved this study (December 2011, project number 114069)

    Effectiveness and costs of a stepwise versus an all-in-one approach to diagnose mild bleeding disorders.

    No full text
    The diagnostic work-up of patients referred to the haematologist for bleeding evaluation is performed in a stepwise way: bleeding history and results of screening laboratory tests guide further diagnostic evaluation. This can be ineffective, time-consuming and burdensome for patients. To improve this strategy, the initial laboratory investigation can be extended. In a model-based approach, effectiveness and costs of a conventional stepwise versus a newly proposed all-in-one diagnostic approach for bleeding evaluation were evaluated and compared, using data from an observational patient cohort study, including adult patients referred for bleeding evaluation. In the all-in-one approach, specialized platelet function tests, coagulation factors, and fibrinolysis tests were included in the initial investigation. Final diagnosis, hospital resource use and costs and patient burden were compared. A total of 150 patients were included. Compared to the stepwise approach, in the all-in-one approach, 19 additional patients reached a diagnosis and patient burden was lower, but total costs per patient were higher [€359, 95% bootstrapped confidence interval (BCI) 283-518, p = 0.001]. For bleeding evaluation of patients referred to the haematologist, an all-in-one diagnostic approach has a higher diagnostic yield and reduces patient burden, at a higher cost. This raises the question what costs justify the diagnosis of a bleeding disorder and a less burdensome diagnostic strategy

    Multiparameter platelet function analysis of bleeding patients with a prolonged platelet function analyser closure time.

    No full text
    Patients referred for evaluation of bleeding symptoms occasionally have a prolonged platelet function analyser (PFA) closure time, without evidence for von Willebrand disease or impaired platelet aggregation. The aim of this study was to establish a shear-dependent platelet function defect in these patients. Patients were included based on high bleeding score and prior PFA prolongation. Common tests of von Willebrand factor (VWF) and platelet function and exome sequencing were performed. Microfluidic analysis of shear-dependent collagen-induced whole-blood thrombus formation was performed. In 14 PFA-only patients, compared to healthy volunteers, microfluidic tests showed significantly lower platelet adhesion and thrombus formation parameters. This was accompanied by lower integrin activation, phosphatidylserine exposure and P-selectin expression. Principal components analysis indicated VWF as primary explaining variable of PFA prolongation, whereas conventional platelet aggregation primarily explained the reduced thrombus parameters under shear. In five patients with severe microfluidic abnormalities, conventional platelet aggregation was in the lowest range of normal. No causal variants in Mendelian genes known to cause bleeding or platelet disorders were identified. Multiparameter assessment of whole-blood thrombus formation under shear indicates single or combined effects of low-normal VWF and low-normal platelet aggregation in these patients, suggesting a shear-dependent platelet function defect, not detected by static conventional haemostatic tests
    corecore