42 research outputs found

    Treatment of Coronary Artery Disease: Sisyphus’ Work?

    Get PDF
    A 37‐year‐old male with a hyperlipidemia type Ha underwent three conventional percutaneous transluminal coronary angioplasty procedures and three surgical revascularizations for recurrent restenosis of the saphenous vein bypass graft. Despite these interventions, a long‐term success was never achieved. Stern implantation at the site of a rerestenosis was successful. However, a second stent implantation to prevent further progression of another previously nonmanipulated atheromateous lesion resulted in a stenosis within the stent for which a new surgical intervention was indicated. At surgery the stented graft was replaced by a fresh venous graft. The partly removed venous graft containing the two stents provides a unique opportunity to study the long‐term histologic effects of intravascular stentin. Copyrigh

    Inter- and intra-observer variability in the qualitative categorization of coronary angiograms.

    Get PDF
    The ABC classification of the American College of Cardiology and the American Heart Association is a commonly used categorization to estimate the risk and success of intracoronary intervention, as well as the probability of restenosis. To evaluate the reliability of qualitative angiogram readings, we randomly selected 200 films from single lesion angioplasty procedures. A repeated visual assessment (> or = 2 months interval) by two independent observers resulted in kappa values of inter and intra-observer variability for the ABC lesion classification and for all separate items that compile it. Variability in assessment is expressed in percentage of total agreement, and in kappa value, which is a parameter of the agreement between two or more observations in excess of the chance agreement. Percentage of total agreement and kappa value was 67.8% and 0.33 respectively for the ABC classification, indicating a poor agreement. Probably this is due to the deficiency of strict definitions. Further investigation has to demonstrate whether improvement can be achieved using complete and detailed definitions without ambiguity, and consensus after panel assessment

    Comparative angiographic quantitative analysis of the immediate efficacy of coronary atherectomy with balloon angioplasty, stenting, and rotational ablation

    Get PDF
    Interventional cardiology has branched in two directions: devices that primarily dilate coronary stenoses and those that debulk coronary tissue. Presently the optimum coronary intervention has not been found. While patients are awaiting randomized trials, a comparison based on matched quantitative coronary analysis may be useful to evaluate results of new interventional techniques. Therefore we compared 51 patients undergoing atherectomy with individually matched patients who were undergoing balloon angioplasty and stenting. The lesions were matched according to location of stenosis and reference diameter. Atherectomy and stenting resulted in larger gains in minimal luminal diameter compared with conventional balloon angioplasty. The minimal luminal diameter was increased from 1.2 +/- 0.4 mm to 2.6 +/- 0.4 mm in the atherectomy group and from 1.2 +/- 0.3 mm to 1.9 +/- 0.4 mm in the angioplasty group (p less than 0.00001). Atherectomy and stenting resulted in similar gains in minimum luminal diameter (1.4 mm vs 1.3 mm, p = NS). In addition, atherectomy and stenting appear to be more effective in resisting elastic recoil because of tissue removal and an intrinsic dilating effect, respectively. In matched populations directional atherectomy and stenting appear to be more effective intracoronary interventional devices than balloon angioplasty based on the immediate results. However, atherectomy is limited in smaller coronary vessels because of its larger size

    Comparison of usefulness of computer assisted continuous 48-h 3-lead with 12-lead ECG ischaemia monitoring for detection and quantitation of ischaemia in patients with unstable angina

    Get PDF
    AIMS: The selection of ECG leads used for ST monitoring may influence detection and quantitation of ischaemia. METHODS: We compared on-line continuous 48-h 12-lead against 3-lead ST monitoring in 130 unstable angina patients (Mortara. ELI-100). Onset and offset of ST episodes were defined by the lead with the first > or = 100 microV ST change relative to baseline and the lead with the latest return to baseline ST level, respectively. ST episodes were calculated for 12 leads and 3 leads (V2, V5, III) separately. RESULTS: ST episodes were detected in 88 patients (77%) by 12-lead and in 71 patients (62%) by 3-lead ST monitoring (P < 0.02). The median number (25.75%) of episodes/patient was 1 (0.3) for 3-lead and 2 (1.6) for 12-lead (P < 0.0001). The total duration of ischaemia detected during 12-lead far exceeded 3-lead monitoring: 12.3 (1, 58.2) and 1.7 (0, 23.3) min respectively (P < 0.0001). The probability of recurrent ischaemia declined most during the first 24 h of monitoring. After a period without ST changes of 1, 12, 24 and 36 h, the probabilities of recurrent ischaemia were 63, 31, 14 and 9%, respectively. CONCLUSIONS: Continuous 12-lead ST monitoring increases detection rate and duration of ST episodes compared to 3-lead ST monitoring. The use of continuous 12-lead ECG monitoring devices on emergency wards and coronary care units is recommended

    Immediate and late outcome of excimer laser and balloon coronary angioplasty: A quantitative angiographic comparison based on matched lesions

    Get PDF
    Objectives.This study sought to compare acute lumen changes and late lumen narrowing during and after excimer laser-assisted balloon angioplasty, measured by quantitative coronary angiography, with the immediate and long-term outcome of balloon angioplasty alone.Background.Although excimer laser coronary angioplasty is used as an adjunct or alternative to balloon angioplasty, limited comparative data exist regarding the immediate and long-term efficacy of excimer laser-assisted balloon angioplasty versus balloon angioplasty alone.Methods.A series of 53 lesions in 47 consecutive patients successfully treated with excimer laser-assisted balloon angioplasty were individually matched after completion of 6-month follow-up angiography with 53 successfully treated balloon angioplasty lesions according to vessel location, preprocedural minimal lumen diameter and reference diameter. Immediate and long-term angiographic results were assessed by an automated lumen contour detection algorithm.Results.Before intervention in the laser and balloon angioplasty groups, respectively, minimal lumen diameter (mean ± SD) was 0.73 ± 0.47 and 0.74 ± 0.46 mm, and reference diameter was 2.71 ± 0.42 and 2.72 ± 0.41 mm. Laser angioplasty was followed by adjunctive balloon dilation in 50 lesions. Mean balloon diameter at maximal inflation was similar in both treatment groups (2.61 ± 0.32 and 2.65 ± 0.38 mm, respectively), resulting in similar minimal lumen diameters after intervention of 1.77 ± 0.41 and 1.78 ± 0.34 mm, respectively. At follow-up angiography, minimal lumen diameter after excimer laser-assisted balloon angioplasty was 1.17 ± 0.63 mm, and that after balloon angioplasty alone was 1.46 ± 0.67 mm (p = 0.02). The angiographic restenosis rates at follow-up using the 50% diameter stenosis cutoff criterion were 57% and 34%, respectively (p = 0.02).Conclusions.Quantitative angiographic analysis of a matched group of 106 successfully treated coronary lesions showed a similar immediate outcome but reduced long-term efficacy of excimer laser-assisted balloon angioplasty compared with that after balloon angioplasty alone

    Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty

    Get PDF
    An attempt to assess the "utility" of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter during intervention and the theoretically achievable gain (i.e., reference diameter). The restenosis index is the ratio between the decrease at follow-up and the initial gain during the procedure. The net result at long-term follow-up is characterized by the utility index, which is the ratio between the final gain in diameter at follow-up and what theoretically could have been achieved. For this purpose, 30 coronary artery lesions were selected from a consecutive series of successfully dilated primary angioplasty lesions and were matched with the initial 30 successfully treated primary atherectomy lesions. Matching by location of stenosis and reference diameter resulted in 2 comparable groups with identical preprocedural stenosis characteristics. Atherectomy resulted in an increase in minimal luminal diameter 2 times larger than angioplasty (1.53 vs 0.77 mm; p less than 0.0001). However, at follow-up there was a significant decrease in minimal luminal diameter and a significant increase in percent diameter stenosis in the groups with atherectomy and angioplasty (1.69 +/- 0.58 vs 1.57 +/- 0.58 mm, p = not significant [NS], and 37 +/- 18 vs 47 +/- 18%, p = NS, respectively). The decrease in minimal luminal gain was more pronounced in the group with atherectomy than in that with angioplasty (0.92 +/- 0.69 vs 0.35 +/- 0.51 mm; p = 0.0005).(ABSTRACT TRUNCATED AT 250 WORDS
    corecore