57 research outputs found

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A model of tuberculosis screening for pregnant women in resource-limited settings using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. TheWorld Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    An Evaluation of the Performance and Acceptability of Three LED Fluorescent Microscopes in Zambia: Lessons Learnt for Scale-Up

    Get PDF
    The World Health Organization recommends the roll-out of light-emitting diode (LED) fluorescent microscopes (FM) as an alternative to light microscopes in resource-limited settings. We evaluated the acceptability and performance of three LED FMs after a short orientation among laboratory technicians from government health centers in Zambia. Sixteen technicians with varied light microscopy experience were oriented to FMs and divided into groups; each group read a different set of 40 slides on each LED FM (Primo Star iLED™, Lumin™, FluoLED™) and on a reference mercury-vapor FM (Olympus BX41TF). Slide reading times were recorded. An experienced FM technician examined each slide on the Olympus BX41TF. Sensitivity and specificity compared to TB culture were calculated. Misclassification compared to the experienced technician and inter-rater reliability between trainees was assessed. Trainees rated microscopes on technical aspects. Primo Star iLED™, FluoLED™ and Olympus BX41TF had comparable sensitivities (67%, 65% and 65% respectively), with the Lumin™ significantly worse (56%; p<0.05). Specificity was low for trainees on all microscopes (75.9%) compared to the experienced technician on Olympus BX41TF (100%). Primo Star iLED™ had significantly less misclassification (21.1% p<0.05) than FluoLED™ (26.5%) and Lumin™ (26.8%) and significantly higher inter-rater reliability (0.611; p<0.05), compared to FluoLED™ (0.523) and Lumin™ (0.492). Slide reading times for LED FMs were slower than the reference, but not significantly different from each other. Primo Star iLED™ rated highest in acceptability measures, followed by FluoLED™ then Lumin™. Primo Star iLED™ was consistently better than FluoLED™ and Lumin™, and performed comparably to the Olympus BX41TF in all analyses, except reading times. The Lumin™ compared least favorably and was thought unacceptable for use. Specificity and inter-rater reliability were low for all microscopes suggesting that a brief orientation was insufficient in this setting. These results provide important data for resource-limited settings to consider as they scale-up LED FMs

    The influence of health systems on breast, cervical and colorectal cancer screening: an overview of systematic reviews using health systems and implementation research frameworks.

    Get PDF
    Objectives Screening for breast, cervical and colorectal cancer in an average-risk population is widely recommended in national and international guidelines although their implementation varies. Using a conceptual framework that draws on implementation and health systems research, we provide an overview of systematic literature reviews that address health system and service barriers or facilitators to effective cancer screening. Methods Using a systematic approach, we searched Cochrane Database of Systematic Reviews, Ovid Medline, Ovid Embase, Web of Science, PsychInfo and other internet sources. We included systematic reviews of screening interventions (i.e. targeting people at average risk) for breast, cervical and colorectal cancer. The analysis included 90 systematic reviews. Results This review identified a multitude of barriers and facilitators affecting the health system, the capabilities of individuals in the system and their intentions. A large proportion of the available evidence focused on uptake. The reviews demonstrated that health system factors influenced participation, as well as quality and effectiveness of the service provided. The barriers with the biggest impact were knowledge/education, mainly of clients but also providers (capability barriers) and beliefs and values (intention barriers) of the eligible population. These findings complement the usual focus on psychological and social barriers to informed participation by individuals that dominate the screening literature. The facilitators with the most supporting evidence were educational interventions (overcoming capability and intention barriers), invitation letters, reminders and appointments. These were mainly directed at eligible individuals and, to a lesser extent, to providers and healthcare professionals. Only a small number of reviews, mainly from Europe, specified organized, rather than opportunistic, screening programmes. In those, low participation was the most frequently cited barrier and invitation letters (including physician endorsement, phone calls and reminders to non-responders and healthcare professionals) were the most prevalent facilitators. Conclusion Despite evidence of barriers and facilitators to screening participation and opportunistic screening, further health systems research covering the entire screening system for organized programmes is required. </jats:sec

    Evolutionarily distinct Resistance proteins detect a pathogen effector through its association with different host targets

    Get PDF
    Knowledge of the evolutionary processes which govern pathogen recognition is critical to understanding durable disease resistance. We determined how Phytophthora infestans effector PiAVR2 is recognised by evolutionarily distinct resistance proteins R2 and Rpi-mcq1. We employed yeast two-hybrid, co-immunoprecipitation, virus-induced gene silencing, transient overexpression, and phosphatase activity assays to investigate the contributions of BSL phosphatases to R2- and Rpi-mcq1-mediated hypersensitive response (R2 HR and Rpi-mcq1 HR, respectively). Silencing PiAVR2 target BSL1 compromises R2 HR. Rpi-mcq1 HR is compromised only when BSL2 and BSL3 are silenced. BSL1 overexpression increases R2 HR and compromises Rpi-mcq1. However, overexpression of BSL2 or BSL3 enhances Rpi-mcq1 and compromises R2 HR. Okadaic acid, which inhibits BSL phosphatase activity, suppresses both recognition events. Moreover, expression of a BSL1 phosphatase-dead (PD) mutant suppresses R2 HR, whereas BSL2-PD and BSL3-PD mutants suppress Rpi-mcq1 HR. R2 interacts with BSL1 in the presence of PiAVR2, but not with BSL2 and BSL3, whereas no interactions were detected between Rpi-mcq1 and BSLs. Thus, BSL1 activity and association with R2 determine recognition of PiAVR2 by R2, whereas BSL2 and BSL3 mediate Rpi-mcq1 perception of PiAVR2. R2 and Rpi-mcq1 utilise distinct mechanisms to detect PiAVR2 based on association with different BSLs, highlighting central roles of these effector targets for both disease and disease resistance

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    Accuracy of GE digital breast tomosynthesis vs supplementary mammographic views for diagnosis of screen-detected soft-tissue breast lesions

    Get PDF
    Objective: To compare the accuracy of standard supplementary views and GE digital breast tomosynthesis (DBT) for assessment of soft-tissue mammographic abnormalities. Methods: Women recalled for further assessment of soft-tissue abnormalities were recruited and received standard supplementary views (typically spot compression views) and two-view GE DBT. The added value of DBT in the assessment process was determined by analysing data collected prospectively by radiologists working up the cases. Following anonymization of cases, there was also a retrospective multireader review. The readers first read bilateral standard two-view digital mammography (DM) together with the supplementary mammographic views and gave a combined score for suspicion of malignancy on a five-point scale. The same readers then read bilateral standard two-view DM together with two-view DBT. Pathology data were obtained. Differences were assessed using receiver operating characteristic analysis. Results: The study population was 342 lesions in 322 patients. The final diagnosis was malignant in 113 cases (33%) and benign/normal in 229 cases (67%). In the prospective analysis, the performance of two-view DM plus DBT was at least equivalent to the performance of two-view DM and standard mammographic supplementary views—the area under the curve (AUC) was 0.946 and 0.922, respectively, which did not reach statistical significance. Similar results were obtained for the retrospective review—AUC was 0.900 (DBT) and 0.873 (supplementary views), which did not reach statistical significance. Conclusion: The accuracy of GE DBT in the assessment of screen detected soft-tissue abnormalities is equivalent to the use of standard supplementary mammographic views. Advances in knowledge: The vast majority of evidence relating to the use of DBT has been gathered from research using Hologic equipment. This study provides evidence for the use of the commercially available GE DBT system demonstrating that it is at least equivalent to supplementary mammographic views in the assessment of soft-tissue screen-detected abnormalities
    corecore