24 research outputs found

    Histopathological diagnosis of Japanese spotted fever using formalin-fixed, paraffin-embedded skin biopsy specimens Usefulness of immunohistochemistry and real-time PCR analysis

    Get PDF
    AbstractJapanese spotted fever (JSF) is caused by Rickettsia japonica, and lethal cases are reported yearly in southwest Japan. We thus established the method of diagnosing JSF by immunohistochemistry (IHC) and real-time PCR (RT-PCR) using formalin-fixed, paraffin-embedded skin biopsy specimens. Two monoclonal antibodies were used for IHC, and the 17k genus common antigen gene served as the target of RT-PCR. We collected skin biopsy (n = 61) and autopsy (n = 1) specimens from 50 patients clinically suspected of JSF. Immunohistochemically, the rickettsial antigens were localized as coarse dots in the cytoplasm of endothelial cells and macrophages. Thirty-one seropositive cases plus one autopsy case (group A) and nine seronegative cases but with positive IHC and/or RT-PCR (group B) were judged as JSF. Nine cases were regarded as non-JSF disorders based on negative serology, IHC and RT-PCR (group C). Of 50 biopsies (eschar 34, eruptions 10, and scabs 6) from groups A and B, IHC and RT-PCR positivities were 94% (32/34) and 62% (21/34) for eschar, 80% (8/10) and 30% (3/10) for eruptions, and 33% (2/6) and 50% (3/6) for scabs. For IHC, eschar was most suitable, and scabs were insufficient. Unexpectedly, 18 biopsies happened to be fixed in 100% formalin, and this lowered the detection rate by RT-PCR, but IHC was tolerant. Sequence analysis using five skin biopsy specimens confirmed a 114 bp DNA stretch homologous to that reported for the target gene of R. japonica. In 26 (84%) of the 31 seropositive patients, the diagnosis was made by IHC and/or RT-PCR earlier than serology

    The clinical practice guideline for the management of ARDS in Japan

    Full text link

    Sivelestat

    No full text

    Sivelestat

    No full text

    COMPARATIVE STUDY ON PERFORMANCE OF VARIOUS ENVIRONMENTAL RADIATION MONITORS

    No full text
    After the Fukushima Daiichi Nuclear Power Plant accident, the radiation dose for first responders was not evaluated accurately due to lack of the monitoring data. It has been important to evaluate a radiation dose for workers in emergency response at a nuclear accident. In this study, a new device which can evaluate both of external and internal exposure doses was developed and the performance of various environmental radiation monitors including commercially available monitors were tested and compared from the viewpoint of an environmental monitoring at emergency situation. Background counts of the monitors and the ambient dose equivalent rate were measured in Fukushima Prefecture. The detection limit for beta particles was evaluated by the method of ISO11929. The sensitivity for gamma-rays of the dust monitor using a ZnS(Ag) and a plastic scintillator was high, but that of the external exposure monitor using a silicon photodiode with CsI(Tl) crystal was relatively low. The detection limit ranged 190–280 Bq m−3 at 100 μSv h−1, exceeding the detection limit of 100 Bq m−3 in the minimum requirement by the National Regulation Authority in Japan. Use of the shielding with lead is necessary to achieve the minimum requirement. These results indicate that the dust monitor using a ZnS(Ag) scintillator and a plastic scintillator is suitable for the external exposure monitor and the developed internal exposure monitor is for the internal exposure monitor at emergency situation among the evaluated monitors. In the future study, the counting efficiency, the relative uncertainty and the performance of the detection for alpha particles will be evaluated, and it will be considered which type of a monitor is suitable after taking the portability into account
    corecore