2,838 research outputs found
A high resolution scintillating fiber tracker with SiPM readout for the PEBS experiment
Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a
mo dular high-resolution charged-particle tracking detector has been designed.
The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating
fiber s of 0.250mm diameter. The fibers are read out by four SiPM arrays (8mm x
1mm) e ach on either end of the module.Comment: 6 pages, 5 figures, presented at the ICATPP 1
Minimal hepatic toxicity of Onyx-015: spatial restriction of coxsackie-adenoviral receptor in normal liver.
We administered an adenoviral vector, Onyx-015, into the hepatic artery of patients with metastatic colorectal cancer involving the liver. Thirty-five patients enrolled in this multi-institutional phase I/II trial received up to eight arterial infusions of up to 2 x 10(12) viral particles. Hepatic toxicity was the primary dose-limiting toxicity observed in preclinical models. However, nearly 200 infusions of this adenoviral vector were administered directly into the hepatic artery without significant toxicity. Therefore, we undertook this analysis to determine the impact of repeated adenoviral exposure on hepatic function. Seventeen patients were treated at our institution, providing a detailed data set on the changes in hepatic function following repeated exposure to adenovirus. No changes in hepatic function occurred with the first treatment of Onyx-015 among these patients. Transient increases in transaminase levels occurred in one patient starting with the second infusion and transient increases in bilirubin was observed in two patients starting with the fifth treatment. These changes occurred too early to be explained by viral-mediated lysis of hepatocytes. In addition, viremia was observed starting 3-5 days after the viral infusion in half of the patient, but was not associated with hepatic toxicity. To further understand the basis for the minimal hepatic toxicity of adenoviral vectors, we evaluated the replication of adenovirus in primary hepatocytes and tumor cells in culture and the expression of the coxsackie-adenoviral receptor (CAR) in normal liver and colon cancer metastatic to the liver. We found that adenovirus replicates poorly in primary hepatocytes but replicates efficiently in tumors including tumors derived from hepatocytes. In addition, we found that CAR is localized at junctions between hepatocytes and is inaccessible to hepatic blood flow. CAR is not expressed on tumor vasculature but is expressed on tumor cells. Spatial restriction of CAR to the intercellular space in normal liver and diminished replication of adenovirus in hepatocytes may explain the minimal toxicity observed following repeated hepatic artery infusions with Onyx-015
Silicon photomultiplier arrays - a novel photon detector for a high resolution tracker produced at FBK-irst, Italy
A silicon photomultiplier (SiPM) array has been developed at FBK-irst having
32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is
subdivided into 5 x 22 rectangularly arranged pixels. These sensors are
developed to read out a modular high resolution scintillating fiber tracker.
Key properties like breakdown voltage, gain and photon detection efficiency
(PDE) are found to be homogeneous over all 32 channels of an SiPM array. This
could make scintillating fiber trackers with SiPM array readout a promising
alternative to available tracker technologies, if noise properties and the PDE
are improved
Dentin sialoprotein, dentin phosphoprotein, enamelysin and ameloblastin, tooth- specific molecules that are distinctively expressed during murine dental differentiation
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73260/1/j.0909-8836.1998.eos106510.x.pd
Enhancement of vaccinia virus based oncolysis with histone deacetylase inhibitors
Histone deacetylase inhibitors (HDI) dampen cellular innate immune response by decreasing interferon production and have been shown to increase the growth of vesicular stomatitis virus and HSV. As attenuated tumour-selective oncolytic vaccinia viruses (VV) are already undergoing clinical evaluation, the goal of this study is to determine whether HDI can also enhance the potency of these poxviruses in infection-resistant cancer cell lines. Multiple HDIs were tested and Trichostatin A (TSA) was found to potently enhance the spread and replication of a tumour selective vaccinia virus in several infection-resistant cancer cell lines. TSA significantly decreased the number of lung metastases in a syngeneic B16F10LacZ lung metastasis model yet did not increase the replication of vaccinia in normal tissues. The combination of TSA and VV increased survival of mice harbouring human HCT116 colon tumour xenografts as compared to mice treated with either agent alone. We conclude that TSA can selectively and effectively enhance the replication and spread of oncolytic vaccinia virus in cancer cells. © 2010 MacTavish et al
A High-resolution Scintillating Fiber Tracker With Silicon Photomultiplier Array Readout
We present prototype modules for a tracking detector consisting of multiple
layers of 0.25 mm diameter scintillating fibers that are read out by linear
arrays of silicon photomultipliers. The module production process is described
and measurements of the key properties for both the fibers and the readout
devices are shown. Five modules have been subjected to a 12 GeV/c proton/pion
testbeam at CERN. A spatial resolution of 0.05 mm and light yields exceeding 20
detected photons per minimum ionizing particle have been achieved, at a
tracking efficiency of more than 98.5%. Possible techniques for further
improvement of the spatial resolution are discussed.Comment: 31 pages, 27 figures, pre-print version of an article published in
Nuclear Instruments and Methods in Physics Research Section A, Vol. 62
A Scintillating Fiber Tracker With SiPM Readout
We present a prototype for the first tracking detector consisting of 250
micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The
detector has a modular design, each module consists of a mechanical support
structure of 10mm Rohacell foam between two 100 micron thin carbon fiber skins.
Five layers of scintillating fibers are glued to both top and bottom of the
support structure. SiPM arrays with a channel pitch of 250 micron are placed in
front of the fibers. We show the results of the first module prototype using
multiclad fibers of types Bicron BCF-20 and Kuraray SCSF-81M that were read out
by novel 32-channel SiPM arrays from FBK-irst/INFN Perugia as well as
32-channel SiPM arrays produced by Hamamatsu. A spatial resolution of 88 micron
+/- 6 micron at an average yield of 10 detected photons per minimal ionizig
particle has been achieved.Comment: 5 pages, 7 figures, submitted as proceedings to the 11th Topical
Seminar on Innovative Particle and Radiation Detectors (IPRD08
PEBS - Positron Electron Balloon Spectrometer
The best measurement of the cosmic ray positron flux available today was
performed by the HEAT balloon experiment more than 10 years ago. Given the
limitations in weight and power consumption for balloon experiments, a novel
approach was needed to design a detector which could increase the existing data
by more than a factor of 100.
Using silicon photomultipliers for the readout of a scintillating fiber
tracker and of an imaging electromagnetic calorimeter, the PEBS detector
features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total
weight of 1500 kg and a power consumption of 600 W. The experiment is intended
to measure cosmic ray particle spectra for a period of up to 20 days at an
altitude of 40 km circulating the North or South Pole.
A full Geant 4 simulation of the detector concept has been developed and key
elements have been verified in a testbeam in October 2006 at CERN.Comment: 5 pages, 7 figures, submitted to Proceedings of the 11th Vienna
Conference on Instrumentatio
Learning and developing science capital through citizen science
Citizen science, the active participation of the public in scientific research projects, is a rapidly expanding field in open science and open innovation. It provides an integrated model of public knowledge production and engagement with science. As a growing worldwide phenomenon, it is invigorated by evolving new technologies that connect people easily and effectively with the scientific community. Catalysed by citizens’ wishes to be actively involved in scientific processes, as a result of recent societal trends, it also offers contributions to the rise in tertiary education. In addition, citizen science provides a valuable tool for citizens to play a more active role in sustainable development.
This book identifies and explains the role of citizen science within innovation in science and society, and as a vibrant and productive science-policy interface. The scope of this volume is global, geared towards identifying solutions and lessons to be applied across science, practice and policy. The chapters consider the role of citizen science in the context of the wider agenda of open science and open innovation, and discuss progress towards responsible research and innovation, two of the most critical aspects of science today
Simulations of methane-air flames using ISAT and ANN
Large-eddy simulations (LES) of turbulent flames with detailed finite-rate kinetics is currently computationally infeasible due to the enormous cost associated with computation of reaction kinetics. Recently, an In-Situ Adaptive Tabulation (ISAT) methodology was shown to reduce the cost of direct integration considerably. However, ISAT tables require significant on-line storage in memory and may result in restriction on massivelly parallel systems. Furthermore, application of ISAT in LES requires reevaluation of the tree structure and the access/retrieval process. Here, issues regarding the use of ISAT in a LES are discussed. Then, a storage-efficient Artificial Neural Network (ANN) is trained using ISAT data and used to simulate turbulent premixed flames in both the thin-reaction-zone and flamelet regimes. Finally, the issues to be addressed in order to apply this combined ISAT/ANN methodology for full-scale LES of reacting flows are discussed
- …