125 research outputs found

    Direct Visualisation of the Depth-Dependent Mechanical Properties of Full-Thickness Articular Cartilage.

    Get PDF
    The structural anisotropy of articular cartilage controls its deformation response. As proteoglycans and collagen vary with depth, simple uniaxial compression results in inhomogeneous deformation with distinct depth-dependent mechanical properties. Investigations into depth-dependent mechanical properties of articular cartilage have previously required tissue modification after specimen isolation. Such modifications include histological processes, freezing, subchondral bone removal, and fluorescent staining that may alter the tissue, limiting in vivo applicability

    Biomechanical characterization of human soft tissues using indentation and tensile testing

    Get PDF
    Tissue biomechanics is important for maintaining cell shape and function and for determining phenotype. This report demonstrates non-destructive mechanical protocols for characterizing elastic and viscoelastic properties of human soft tissues, which can be directly applied to tissue-engineered substrates to allow a close matching of engineered materials to native tissue

    Optimising the decellularization of human elastic cartilage with trypsin for future use in ear reconstruction

    Get PDF
    Decellularized scaffolds can induce chondrogenic differentiation of stem cells. This study compares different methods to optimise the decellularization of auricular cartilage. The process consisted of an initial 12 hour dry freeze thaw which froze the cartilage specimens in an empty tube at −20 °C. Samples were allowed to thaw at room temperature followed by submersion in phosphate buffer solution in which they were frozen at −20 °C for a 12 hour period. They were then allowed to thaw at room temperature as before. Protocol A subsequently involved subjecting specimens to both deoxyribonuclease and sodium deoxycholate. Protocol B and C were adaptations of this using 0.25% trypsin (7 cycles) and a 0.5 molar solution of ethylenediaminetetraacetic acid (3 hours for each cycle) respectively as additional steps. Trypsin accelerated the decellularization process with a reduction in DNA content from 55.4 ng/μL (native) to 17.3 ng/μL (P-value < 0.05) after 14 days. Protocol B showed a faster reduction in DNA content when compared with protocol A. In comparison to protocol C after 14 days, trypsin also showed greater decellularization with a mean difference of 11.7 ng/μL (P-value < 0.05). Histological analysis with H&E and DAPI confirmed depletion of cells at 14 days with trypsin

    Biomechanical Characterisation of the Human Auricular Cartilages; Implications for Tissue Engineering

    Get PDF
    Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects biocompatibility and extrusion. The aim of this study was to determine the biomechanical properties of human auricular cartilage. Auricular cartilage from fifteen cadavers was indented with displacement of 1 mm/s and load of 300 g to obtain a Young's modulus in compression. Histological analysis of the auricle was conducted according to glycoprotein, collagen, and elastin content. The compression modulus was calculated for each part of the auricle with the tragus at 1.67 ± 0.61 MPa, antitragus 1.79 ± 0.56 MPa, concha 2.08 ± 0.70 MPa, antihelix 1.71 ± 0.63 MPa, and helix 1.41 ± 0.67 MPa. The concha showed to have a significantly greater Young's Elastic Modulus than the helix in compression (p < 0.05). The histological analysis demonstrated that the auricle has a homogenous structure in terms of chondrocyte morphology, extracellular matrix and elastin content. This study provides new information on the compressive mechanical properties and histological analysis of the human auricular cartilage, allowing surgeons to have a better understanding of suitable replacements. This study has provided a reference, by which cartilage replacements should be developed for auricular reconstruction

    Biomechanical characterisation of the human nasal cartilages; implications for tissue engineering

    Get PDF
    Nasal reconstruction is currently performed using autologous grafts provides but is limited by donor site morbidity, tissue availability and potentially graft failure. Additionally, current alternative alloplastic materials are limited by their high extrusion and infection rates. Matching mechanical properties of synthetic materials to the native tissue they are replacing has shown to be important in the biocompatibility of implants. To date the mechanical properties of the human nasal cartilages has not been studied in depth to be able to create tissue-engineered replacements with similar mechanical properties to native tissue. The young's modulus was characterized in compression on fresh-frozen human cadaveric septal, alar, and lateral cartilage. Due to the functional differences experienced by the various aspects of the septal cartilage, 16 regions were evaluated with an average elastic modulus of 2.72 ± 0.63 MPa. Furthermore, the posterior septum was found to be significantly stiffer than the anterior septum (p < 0.01). The medial and lateral alar cartilages were tested at four points with an elastic modulus ranging from 2.09 ± 0.81 MPa, with no significant difference between the cartilages (p < 0.78). The lateral cartilage was tested once in all cadavers with an average elastic modulus of 0.98 ± 0.29 MPa. In conclusion, this study provides new information on the compressive mechanical properties of the human nasal cartilage, allowing surgeons to have a better understanding of the difference between the mechanical properties of the individual nasal cartilages. This study has provided a reference, by which tissue-engineered should be developed for effective cartilage replacements for nasal reconstruction

    Comparison of the mechanical properties of different skin sites for auricular and nasal reconstruction

    Get PDF
    Background: Autologous and synthetic nasal and auricular frameworks require skin coverage. The surgeon’s decides on the appropriate skin coverage for reconstruction based on colour matching, subcutaneous tissue thickness, expertise and experience. One of the major complications of placing subcutaneous implants is the risk of extrusion (migration through the skin) and infection. However, knowledge of lessening the differential between the soft tissue and the framework can have important implications for extrusion. This study compared the mechanical properties of the skin commonly used as skin sites for the coverage in auricular and nasal reconstruction. Methods: Using ten fresh human cadavers, the tensile Young’s Modulus of the skin from the forehead, forearm, temporoparietal, post-auricular and submandibular neck was assessed. The relaxation rate and absolute relaxation level was also assessed after 90 min of relaxation. Results: The submandibular skin showed the greatest Young’s elastic modulus in tension of all regions (1.28 MPa ±0.06) and forearm showed the lowest (1.03 MPa ±0.06). The forehead demonstrated greater relaxation rates among the different skin regions (7.8 MPa−07 ± 0.1). The forearm showed the lowest rate of relaxation (4.74 MPa−07 ± 0.1). The forearm (0.04 MPa ±0.004) and submandibular neck skin (0.04 MPa ±0.005) showed similar absolute levels of relaxation, which were significantly greater than the other skin regions (p < 0.05). Conclusions: This study provides an understanding into the biomechanical properties of the skin of different sites allowing surgeons to consider this parameter when trying to identify the optimal skin coverage in nasal and auricular reconstructio

    Nanoscale structure, dynamics and power conversion efficiency correlations in small molecule and oligomer-based photovoltaic devices

    Get PDF
    Photovoltaic functions in organic materials are intimately connected to interfacial morphologies of molecular packing in films on the nanometer scale and molecular levels. This review will focus on current studies on correlations of nanoscale morphologies in organic photovoltaic (OPV) materials with fundamental processes relevant to photovoltaic functions, such as light harvesting, exciton splitting, exciton diffusion, and charge separation (CS) and diffusion. Small molecule photovoltaic materials will be discussed here. The donor and acceptor materials in small molecule OPV devices can be fabricated in vacuum-deposited, multilayer, crystalline thin films, or spin-coated together to form blended bulk heterojunction (BHJ) films. These two methods result in very different morphologies of the solar cell active layers. There is still a formidable debate regarding which morphology is favored for OPV optimization. The morphology of the conducting films has been systematically altered; using variations of the techniques above, the whole spectrum of film qualities can be fabricated. It is possible to form a highly crystalline material, one which is completely amorphous, or an intermediate morphology. In this review, we will summarize the past key findings that have driven organic solar cell research and the current state-of-the-art of small molecule and conducting oligomer materials. We will also discuss the merits and drawbacks of these devices. Finally, we will highlight some works that directly compare the spectra and morphology of systematically elongated oligothiophene derivatives and compare these oligomers to their polymer counterparts. We hope this review will shed some new light on the morphology differences of these two systems

    Effects of bone damage on creep behaviours of human vertebral trabeculae

    Get PDF
    A subgroup of patients suffering with vertebral fractures can develop progressive spinal deformities over time. The mechanism underlying such clinical observation, however, remains unknown. Previous studies suggested that creep deformation of the vertebral trabeculae may play a role. Using the acoustic emission (AE) technique, this study investigated effects of bone damage (modulus reduction) on creep behaviours of vertebral trabecular bone. Thirty-seven human vertebral trabeculae samples were randomly assigned into five groups (A to E). Bones underwent mechanical tests using similar experimental protocols but varied degree of bone damage was induced. Samples first underwent creep test (static compressive stress of 0.4 MPa) for 30 minutes, and then were loaded in compression to a specified strain level (0.4%, 1.0%, 1.5%, 2.5%, and 4% for group A to E, respectively) to induce different degrees of bone damage (0.4%, no damage control; 1.0%, yield strain; 1.5%, beyond yield strain, 2.5% and 4%, post-ultimate strains). Samples were creep loaded (0.4 MPa) again for 30 minutes. AE techniques were used to monitor bone damage. Bone damage increased significantly from group A to E (P<0.05), with more than 30% of modulus reduction in group D and E. Before compressive loading, creep deformation was not different among the five groups and AE hits in creep test were rare. After compressive loading, creep deformation was significantly greater in group D and E than those in other groups (P<0.05). The number of AE hits and other AE measurements during creep test were significantly greater in group D and E than in group A, B, and C (P<0.05 for all). Data suggested that with the increase of vertebral trabecular bone damage, substantial creep deformation may occur even when the vertebra was under physiological loads. The boosted creep deformation observed may be attributed to newly created trabecular microfractures. Findings provide a possible explanation as to why some vertebral fracture patients develop progressive spinal deformity over time

    The Grizzly, April 15, 2004

    Get PDF
    Ursinus College Commencement Only One Month Away • Taking Our Place Campaign • Meet This Year\u27s Valedictorians • Silence Makes a Statement • Opinions: Make a Statement with Silence; Class of 2004 Campaigns Hard!; Hyped About Housing; Higher Gas Prices = Economical Cars • Faculty Spotlight: Houghton Kane • Chess Club Results • Who\u27s Who at Ursinus • Softball Team Continues to Shut Down Opponents • Ursinus Outdoor Track and Field: Experience for a Young Team • Baseball Team Trying to be a Contender • Grimmel, Furman Earn All-American Honors at NCGA Championships • Durkin Named CC Player of the Weekhttps://digitalcommons.ursinus.edu/grizzlynews/1559/thumbnail.jp

    The Grizzly, February 7, 2002

    Get PDF
    The Bluelight Hits a Stoplight: Kmart Files for Chapter 11 • Reinstatement of Zeta Chi Charter On Hold • Alan Morrison and Friends to Perform at Heefner Organ Recital • Opinions: Not Everyone Loves Valentine\u27s Day; Tri Sig Strikes Back; Nowhere to Park • Wynton Marsalis is Coming to Campus! • Berman Museum: A Fun and Relaxing Alternative • When the Weather Outside is Frightful • Comparative Pricing Report: Cell Phone Plans • Spring Fashion Preview for Women • Record Breaking Results at Widener Invitational for UC Track & Field • Hussey Twins are Double Trouble • Bears Turn the Bullet in the Opposite Direction • Gymnastics Gods Shine on Johnson; Girls Set Three School Records in Second Straight Win • Men\u27s Basketball Splits Two League Games • UC Women\u27s Basketball Hits Three Game Winning Streak • UC Women\u27s Lacrosse Aiming for Final Four in 2002 • Bears Swimming Claws Their way Through the Water, Falling Short to a Powerful Franklin and Marshall Teamhttps://digitalcommons.ursinus.edu/grizzlynews/1506/thumbnail.jp
    corecore