4,454 research outputs found

    CLEO-c and CESR-c: A New Frontier in Weak and Strong Interactions

    Full text link
    We report on the physics potential of a proposed conversion of the CESR machine and the CLEO detector to a charm and QCD factory: CLEO-c and CESR-c that will make crucial contributions to flavor physics in this decade and offers our best hope for mastering non-perturbative QCD which is essential if we are to understand strongly coupled sectors in the new physics that lies beyond the Standard Model.Comment: 11 pages, 8 figures, submitted to the proceedings of the 9th International Symposium on Heavy Flavor Physics, September 10-13, 2001, Caltech, Pasadena, US

    Towards Coherent Neutrino Detection Using Low-Background Micropattern Gas Detectors

    Get PDF
    The detection of low energy neutrinos (<< few tens of MeV) via coherent nuclear scattering remains a holy grail of sorts in neutrino physics. This uncontroversial mode of interaction is expected to profit from a sizeable increase in cross section proportional to neutron number squared in the target nucleus, an advantageous feature in view of the small probability of interaction via all other channels in this energy region. A coherent neutrino detector would open the door to many new applications, ranging from the study of fundamental neutrino properties to true "neutrino technology". Unfortunately, present-day radiation detectors of sufficiently large mass (>> 1 kg) are not sensitive to sub-keV nuclear recoils like those expected from this channel. The advent of Micropattern Gas Detectors (MPGDs), new technologies originally intended for use in High Energy Physics, may soon put an end to this impasse. We present first tests of MPGDs fabricated with radioclean materials and discuss the approach to assessing their sensitivity to these faint signals. Applications are reviewed, in particular their use as a safeguard against illegitimate operation of nuclear reactors. A first industrial mass production of Gas Electron Multipliers (GEMs) is succinctly described.Comment: Presented at the 2002 IEEE Nuclear Science Symposium and Medical Imaging Conference, Norfolk VA, November 10-16. Submitted to IEEE Tran. Nucl. Sci. Five pages, eight figure

    Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons

    Full text link
    In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imagin

    Characterisation of the Medipix3 detector for 60 and 80 keV electrons

    Get PDF
    In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies &lt;100 keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging

    GEM Operation in Negative Ion Drift Gas Mixtures

    Full text link
    The first operation of GEM gas gain elements in negative ion gas mixtures is reported. Gains up to several thousand were obtained from single-stage GEMs in carbon disulfide vapor at low pressure, and in mixtures of carbon disulfide with Argon and Helium, some near 1 bar total pressure.Comment: 7 pages, 3 figure

    An aging study of a MICROMEGAS with GEM preamplification

    Get PDF
    Abstract We have conducted the first study of the aging behavior of a MICROMEGAS detector with GEM preamplification. Because a MICROMEGAS is constructed with minimal insulation and because the electric field is parallel to the amplification gap, superior radiation hardness was previously reported in an Ar-Isobutane gas mixture in a stand-alone device. The MICROMEGAS is expected to tolerate an even larger accumulated charge in a cleaner gas mixture, such as Ar-CO 2 . However, using a MICROMEGAS as a stand-alone device in this mixture could increase discharge probability and lead to faster degradation in detector performance. We show that this problem can be circumvented by employing GEM preamplification. Although it has been previously shown that a GEM ages when operated at a large gain, sharing the gain between a MICROMEGAS and the GEM creates a high-gain, very radiation-hard gas detector. We find that a MICROMEGAS + GEM combination exhibits no deterioration in performance after a total charge accumulation of 23 mC/mm 2

    Measurement of the Neutron Lifetime by Counting Trapped Protons in a Cold Neutron Beam

    Full text link
    A measurement of the neutron lifetime τn\tau_{n} performed by the absolute counting of in-beam neutrons and their decay protons has been completed. Protons confined in a quasi-Penning trap were accelerated onto a silicon detector held at a high potential and counted with nearly unit efficiency. The neutrons were counted by a device with an efficiency inversely proportional to neutron velocity, which cancels the dwell time of the neutron beam in the trap. The result is τn=(886.6±1.2[stat]±3.2[sys])\tau_{n} = (886.6\pm1.2{\rm [stat]}\pm3.2{\rm [sys]}) s, which is the most precise measurement of the lifetime using an in-beam method. The systematic uncertainty is dominated by neutron counting, in particular the mass of the deposit and the 6^{6}Li({\it{n,t}}) cross section. The measurement technique and apparatus, data analysis, and investigation of systematic uncertainties are discussed in detail.Comment: 71 pages, 20 figures, 9 tables; submitted to PR

    Charm production in nonresonant e(+)e(-) annihilations at √s =10.55 GeV

    Get PDF
    This is the publisher's version also available electronically from http://journals.aps.org/prd/abstract/10.1103/PhysRevD.37.1719We report results on the differential and total cross sections for inclusive production of the charmed particles D*+, D*(0), D(0), D(+), D(s), and Λc in e(+)e(-) annihilations at √s=10.55 GeV. Widely used quark fragmentation models are discussed and compared with the measured charmed-particle momentum distributions. This comparison, as well as that with measurements at other center-of-mass energies, shows the need to take QCD corrections into account and their importance for a correct interpretation of the model parameters. The observed rate of D(0) and D(+) production is compared to the expected total charm production cross section. We measure the probability of a charmed meson being produced as a vector meson and the D*(+) decay branching fraction into D(0)π+

    Testbeam and Laboratory Characterization of CMS 3D Pixel Sensors

    Full text link
    The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase in luminosity expected with the High- Luminosity LHC (HL-LHC) phase. As a possible replacement for planar sensors, 3D silicon technology is under consideration due to its good performance after high radiation fluence. In this paper, we report on pre- and post- irradiation measurements for CMS 3D pixel sensors with different electrode configurations. The effects of irradiation on electrical properties, charge collection efficiency, and position resolution of 3D sensors are discussed. Measurements of various test structures for monitoring the fabrication process and studying the bulk and surface properties, such as MOS capacitors, planar and gate-controlled diodes are also presented.Comment: 14 page
    • 

    corecore