5 research outputs found

    Alcohol septal ablation or mavacamten for obstructive hypertrophic cardiomyopathy

    No full text
    Hypertrophic cardiomyopathy (HCM) is a genetic disease characterized by an increased left ventricular wall thickness in the absence of increased afterload conditions. In addition to diastolic dysfunction, obstruction of the left ventricular outflow tract is common in HCM and has an important influence on symptoms and outcome. Over the last five decades or two decades, respectively, surgical myectomy and alcohol septal ablation were the only therapeutic options if standard medical care was not sufficient. Recently, a new option has become available that has the potential to revolutionize the therapeutic strategies for patients with HCM. Mavacamten is a myosin inhibitor that belongs to a completely new drug class and targets the excessive actin–myosin cross-bridging that is the underlying pathology of HCM. By reducing the actin–myosin interactions, mavacamten not only reduces the left ventricular outflow tract (LVOT) obstruction but also seems to have positive effects on the diastolic function, microcirculation, and cardiac structure. This article summarizes the current evidence on alcohol septal ablation and reviews the preclinical and clinical data on mavacamten for the treatment of patients with obstructive HCM

    Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device

    No full text
    Objective\bf Objective Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. Method\bf Method Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18–24 F. This collective was divided into two groups: group 1, with a sheath diameter of 18F (G1, n = 94), consisted of patients with 18F Medtronic Sentrant and 18 F Direct Flow sheaths, and group 2 with a sheath diameter of 19–24 F (G2, n = 89) consisted of patients with Edwards expandable e-sheath and Solopath sheaths. Perclose-Proglide® was used as a closure device in all patients. Results\bf Results G1 had significantly more female patients (64.9% vs. 46.1% in G2, p = 0.01) and the average BMI was lower (26 ±\pm 4.5% vs. 27.4 ±\pm 4.7%, p = 0.03). There was no significant difference in the incidence of major and minor vascular complications (G1: 12.8% vs. G2: 12.4%, p = 0.9). 30-day mortality was similar in both groups (G1: 6.4 ±\pm 2.5% [95% CI: 0.88–0.98], G2: 3.7 ±\pm 1.9% [95% CI: 0.92–0.99]. The Kaplan Meier analysis of survival revealed no significant differences either. Conclusion\bf Conclusion The difference in sheath diameter had no effect on either incidence or severity of vascular complications. There was no impact on mortality either

    Infective endocarditis after isolated aortic valve replacement

    No full text
    Background and aims\textbf {Background and aims} Prosthetic valve endocarditis (PVE) is the prognostically most unfavourable complication after aortic valve replacement. This study aims to contribute to a better understanding of the different pathological and therapeutical aspects between PVE following surgical (SAVR) and transcatheter aortic valve replacement (TAVI). Methods\bf Methods All patients who had undergone primary isolated SAVR (n\it n = 3447) or TAVI (n\it n = 2269) at our Centre between 01/2012 and 12/2018 were analysed. Diagnosis of PVE was based on Duke criteria modified in 2015. Incidence, risk factors, pathogens, impact of complications or therapy on mortality were analysed and compared between SAVR- and TAVI-PVE. Results\bf Results PVE incidence did not differ significantly after SAVR with 4.9/100 patient-years and TAVI with 2.4/100 patient-years (p\it p = 0.49), although TAVI patients were older (mean 80 vs. 67 years) and had more comorbidities (STS score mean 5.9 vs. 1.6) (p\it p  0.05). Propensity-score matching analysis showed that the type of aortic valve replacement had no effect on the development of post-procedural PVE (p\it p = 0.997). One-year survival was higher in TAVI-PVE patients treated with antibiotics only compared to additional surgical therapy (90.9% vs. 33.3%; p\it p = 0.005). In SAVR-PVE patients, both therapies were comparable in terms of survival (p\it p = 0.861). However, SAVR-PVE patients who were not operated, despite ESC-guideline recommendation, had significantly poorer one-year survival (p\it p = 0.004). Conclusion\bf Conclusion TAVI patients did not have a significantly higher risk to develop PVE. Our data suggest that TAVI-PVE patients in contrast to SAVR-PVE patients can more often be treated with antibiotics only, presumably due to the lack of a polymeric suture ring

    Hemodynamic performance of two current-generation transcatheter heart valve prostheses in severely calcified aortic valve stenosis

    No full text
    Background: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. Methods: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. Results: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p\it p ≤\leq 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p\it p ≤\leq 0.001), as well as predicted EOAi (1 vs. 0.9, p\it p ≤\leq 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p\it p ≤\leq 0.001), as well as severe PPM (2.9% vs. 8.8%, p\it p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. Conclusions: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design

    Impact of device landing zone calcification patterns on paravalvular regurgitation after transcatheter aortic valve replacement with different next-generation devices

    No full text
    Objective\bf Objective Residual paravalvular regurgitation (PVR) has been associated to adverse outcomes after transcatheter aortic valve replacement (TAVR). This study sought to evaluate the impact of device landing zone (DLZ) calcification on residual PVR after TAVR with different next-generation transcatheter heart valves. Methods\bf Methods 642 patients underwent TAVR with a SAPIEN 3 (S3; n=292), ACURATE neo (NEO; n=166), Evolut R (ER; n=132) or Lotus (n=52). Extent, location and asymmetry of DLZ calcification were assessed from contrast-enhanced CT imaging and correlated to PVR at discharge. Results\bf Results PVR was ≥moderate in 0.7% of S3 patients, 9.6% of NEO patients, 9.8% of ER patients and 0% of Lotus patients (p<0.001), and these differences remained after matching for total DLZ calcium volume. The amount of DLZ calcium was significantly related to the degree of PVR in patients treated with S3 (p=0.045), NEO (p=0.004) and ER (p<0.001), but not in Lotus patients (p=0.698). The incidence of PVR ≥moderate increased significantly over the tertiles of DLZ calcium volume (p=0.046). On multivariable analysis, calcification of the aortic valve cusps, LVOT calcification and the use of self-expanding transcatheter aortic valve implantation (TAVI) prostheses emerged as predictors of PVR. Conclusions\bf Conclusions The susceptibility to PVR depending on the amount of calcium was mainly observed in self-expanding TAVI prostheses. Thus, DLZ calcification is an important factor to be considered in prosthesis selection for each individual patient, keeping in mind the trade-off between PVR reduction, risk of new pacemaker implantation and unfavourable valve ha emodynamics
    corecore