19 research outputs found

    Atrial substrate characterization based on bipolar voltage electrograms acquired with multipolar, focal and mini-electrode catheters.

    Get PDF
    BACKGROUND Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters

    A single-beat algorithm to discriminate farfield from nearfield bipolar voltage electrograms from the pulmonary veins.

    Get PDF
    BACKGROUND Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation. METHODS During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled. BVEs were classified using four different machine learning algorithms based on four frequency domain (high-frequency power (PHF), low-frequency power (PLF), relative high power band, PHF ratio of neighbouring electrodes) and two time domain features (amplitude (Vmax), slew rate). The algorithm-based classification was compared to the true identification gained during the PVI and to a classification by cardiac electrophysiologists. RESULTS We included 335 BVEs from 57 consecutive patients. Using a single feature, PHF with a cut-off at 150 Hz showed the best overall accuracy for classification (79.4%). By combining PHF with Vmax, overall accuracy was improved to 82.7% with a specificity of 89% and a sensitivity of 77%. The overall accuracy was highest for the right inferior PV (96.6%) and lowest for the left superior PV (76.9%). The algorithm showed comparable accuracy to the classification by the EP specialists. CONCLUSIONS An automated farfield-nearfield discrimination based on two simple features from a single-beat BVE is feasible with a high specificity and comparable accuracy to the assessment by experienced cardiac electrophysiologists

    Gastric Emptying Time and Volume of the Small Intestine as Objective Markers in Patients With Symptoms of Diabetic Enteropathy

    Get PDF
    BACKGROUND/AIMS: Patients with diabetes mellitus (DM) often suffer from gastrointestinal (GI) symptoms, but these correlate poorly to established objective GI motility measures. Our aim is to perform a detailed evaluation of potential measures of gastric and small intestinal motility in patients with DM type 1 and severe GI symptoms. METHODS: Twenty patients with DM and 20 healthy controls (HCs) were included. GI motility was examined with a 3-dimensional-Transit capsule, while organ volumes were determined by CT scans. RESULTS: Patients with DM and HCs did not differ with regard to median gastric contraction frequency (DM 3.0 contractions/minute [interquartile range {IQR}, 2.9-3.0]; HCs 2.9 [IQR, 2.8-3.1]; P = 0.725), amplitude of gastric contractions (DM 9 mm [IQR, 8-11]; HCs 11 mm (IQR, 9-12); P = 0.151) or fasting volume of the stomach wall (DM 149 cm3 [IQR, 112-187]; HCs 132 cm3 [IQR, 107-154]; P = 0.121). Median gastric emptying time was prolonged in patients (DM 3.3 hours [IQR, 2.6-4.6]; HCs 2.4 hours [IQR, 1.8-2.7]; P = 0.002). No difference was found in small intestinal transit time (DM 5 hours [IQR, 3.7-5.6]; HCs 4.8 hours [IQR, 3.9-6.0]; P = 0.883). However, patients with DM had significantly larger volume of the small intestinal wall (DM 623 cm3 [IQR, 487-766]; HCs 478 cm3 [IQR, 393-589]; P = 0.003). Among patients, 13 (68%) had small intestinal wall volume and 9 (50%) had gastric emptying time above the upper 95% percentile of HCs. CONCLUSION: In our study, gastric emptying time and volume of the small intestinal wall appeared to be the best objective measures in patients with DM type 1 and symptoms and gastroenteropathy

    Gastric transit and small intestinal transit time and motility assessed by a magnet tracking system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tracking an ingested magnet by the Magnet Tracking System MTS-1 (Motilis, Lausanne, Switzerland) is an easy and minimally-invasive method to assess gastrointestinal transit. The aim was to test the validity of MTS-1 for assessment of gastric transit time and small intestinal transit time, and to illustrate transit patterns detected by the system.</p> <p>Methods</p> <p>A small magnet was ingested and tracked by an external matrix of 16 magnetic field sensors (4 × 4) giving a position defined by 5 coordinates (position: <b>x, y, z, and angle: θ, ϕ)</b>. Eight healthy subjects were each investigated three times: (1) with a small magnet mounted on a capsule endoscope (PillCam); (2) with the magnet alone and the small intestine in the fasting state; and (3) with the magnet alone and the small intestine in the postprandial state.</p> <p>Results</p> <p>Experiment (1) showed good agreement and no systematic differences between MTS-1 and capsule endoscopy when assessing gastric transit (median difference 1 min; range: 0-6 min) and small intestinal transit time (median difference 0.5 min; range: 0-52 min). Comparing experiments (1) and (2) there were no systematic differences in gastric transit or small intestinal transit when using the magnet-PillCam unit and the much smaller magnetic pill. In experiments (2) and (3), short bursts of very fast movements lasting less than 5% of the time accounted for more than half the distance covered during the first two hours in the small intestine, irrespective of whether the small intestine was in the fasting or postprandial state. The mean contraction frequency in the small intestine was significantly lower in the fasting state than in the postprandial state (9.90 min<sup>-1 </sup>vs. 10.53 min<sup>-1</sup>) (p = 0.03).</p> <p>Conclusion</p> <p>MTS-1 is reliable for determination of gastric transit and small intestinal transit time. It is possible to distinguish between the mean contraction frequency of small intestine in the fasting state and in the postprandial state.</p

    Association of Heart Rate Variability With Silent Brain Infarcts in Patients With Atrial Fibrillation

    Get PDF
    Purpose: Silent brain infarcts (SBI) are frequently detected in patients with atrial fibrillation (AF), but it is unknown whether SBI are linked to autonomic dysfunction. We aimed to explore the association of autonomic dysfunction with SBI in AF patients. Methods: 1,358 AF patients without prior stroke or TIA underwent brain MRI and 5-min resting ECG. We divided our cohort into AF patients who presented in sinus rhythm (SR-group, n = 816) or AF (AF-group, n = 542). HRV triangular index (HRVI), standard deviation of normal-to-normal intervals, mean heart rate, root mean square root of successive differences of normal-to-normal intervals, 5-min total power and power in the low frequency, high frequency and very low frequency range were calculated. Primary outcome was presence of SBI in the SR group, defined as large non-cortical or cortical infarcts. Secondary outcomes were SBI volumes and topography. Results: Mean age was 72 ± 9 years, 27% were female. SBI were detected in 10.5% of the SR group and in 19.9% of the AF group (p < 0.001). HRVI <15 was the only HRV parameter associated with the presence of SBI after adjustment for clinical covariates in the SR group [odds ratio (OR) 1.67; 95% confidence interval (CI): 1.03–2.70; p = 0.037]. HRVI <15 was associated with larger brain infarct volumes [β (95% CI) −0.47 (−0.84; −0.09), p = 0.016] in the SR group and was more frequently observed in patients with right- than left-hemispheric SBI (p = 0.017). Conclusion: Impaired HRVI is associated with SBI in AF patients. AF patients with autonomic dysfunction might undergo systematic brain MRI screening to initiate intensified medical treatment

    Prognostic significance of anti-p53 and anti-KRas circulating antibodies in esophageal cancer patients treated with chemoradiotherapy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>P53 mutations are an adverse prognostic factor in esophageal cancer. P53 and KRas mutations are involved in chemo-radioresistance. Circulating anti-p53 or anti-KRas antibodies are associated with gene mutations. We studied whether anti-p53 or anti-KRas auto-antibodies were prognostic factors for response to chemoradiotherapy (CRT) or survival in esophageal carcinoma.</p> <p>Methods</p> <p>Serum p53 and KRas antibodies (abs) were measured using an ELISA method in 97 consecutive patients treated at Saint Louis University Hospital between 1999 and 2002 with CRT for esophageal carcinoma (squamous cell carcinoma (SCCE) 57 patients, adenocarcinoma (ACE) 27 patients). Patient and tumor characteristics, response to treatment and the follow-up status of 84 patients were retrospectively collected. The association between antibodies and patient characteristics was studied. Univariate and multivariate survival analyses were conducted.</p> <p>Results</p> <p>Twenty-four patients (28%) had anti-p53 abs. Abs were found predominantly in SCCE (p = 0.003). Anti-p53 abs were associated with a shorter overall survival in the univariate analysis (HR 1.8 [1.03-2.9], p = 0.04). In the multivariate analysis, independent prognostic factors for overall and progression-free survival were an objective response to CRT, the CRT strategy (alone or combined with surgery [preoperative]) and anti-p53 abs. None of the long-term survivors had p53 abs. KRas abs were found in 19 patients (23%, no difference according to the histological type). There was no significant association between anti-KRas abs and survival neither in the univariate nor in the multivariate analysis. Neither anti-p53 nor anti-KRas abs were associated with response to CRT.</p> <p>Conclusions</p> <p>Anti-p53 abs are an independent prognostic factor for esophageal cancer patients treated with CRT. Individualized therapeutic approaches should be evaluated in this population.</p

    Fresh Air Manufacturing Company Shipping Dock Expansion and Site Optimization

    No full text
    The Ascension Group has created a solution to maximize the usable space of Fresh Air Manufacturing Company (FAMCO). Over the past 3 years, FAMCO has experienced 20% growth per year in sales, and expect that they will continue to grow at this rate. As a result, their current shipping facility is not adequate to keep up with the increased demand. In addition, as the company expands, there has been an issue with a lack of parking on site. Space is limited, due to the property layout and proximity to other buildings and the road. Ascension Group has reduced these limitations by providing consultative services that have addressed new loading docks, parking, and access solutions. FAMCO has requested several designs so that they may get an estimate for the project cost, in order to determine the benefits of the renovations. Ascension Group used field-based methods and computational analysis to complete several designs that maximize shipping and receiving capabilities while also increasing on-site parking for employees. Solutions will be presented in the form of a poster

    Pediatric Size Swallowable Glass Pill for Digestive Motility Analysis

    No full text
    A glass pill for digestive motility tracking with wireless communication is presented. The pill encapsulates three magnetic transmitter coils with a 125 kHz signal, the circuitry required to control the magnetic coil output and the battery. The system provides real time location of the pill inside the digestive tract of the patient using an external detector housed in a wearable jacket. The custom integrated circuit for this application reduces bill-of-materials (BOM) count and significant reduction in power consumption therefore resulting in further size reduction by adapting a smaller battery package. The outcome of the circuit integration enables the glass pill for pediatric use while providing a total pill diameter of 6 mm. The glass pill system operates continuously for 48 hours with a 1.55 V 8 mAh coin cell battery with an average power consumption of 250 microwatts
    corecore