784 research outputs found

    Social representations of HIV/AIDS in five Central European and Eastern European countries: A multidimensional analysis

    Get PDF
    Cognitive processing models of risky sexual behaviour have proliferated in the two decades since the first reporting of HIV/AIDS, but far less attention has been paid to individual and group representations of the epidemic and the relationship between these representations and reported sexual behaviours. In this study, 494 business people and medics from Estonia, Georgia, Hungary, Poland and Russia sorted free associations around HIV/AIDS in a matrix completion task. Exploratory factor and multidimensional scaling analyses revealed two main dimensions (labelled ‘Sex’ and ‘Deadly disease’), with significant cultural and gender variations along both dimension scores. Possible explanations for these results are discussed in the light of growing concerns over the spread of the epidemic in this region

    Using curvature information in haptic shape perception of 3D objects

    Get PDF
    Are humans able to perceive the circularity of a cylinder that is grasped by the hand? This study presents the findings of an experiment in which cylinders with a circular cross-section had to be distinguished from cylinders with an elliptical cross-section. For comparison, the ability to distinguish a square cuboid from a rectangular cuboid was also investigated. Both elliptical and rectangular shapes can be characterized by the aspect ratio, but elliptical shapes also contain curvature information. We found that an elliptical shape with an aspect ratio of only 1.03 could be distinguished from a circular shape both in static and dynamic touch. However, for a rectangular shape, the aspect ratio needed to be about 1.11 for dynamic touch and 1.15 for static touch in order to be discernible from a square shape. We conclude that curvature information can be employed in a reliable and efficient manner in the perception of 3D shapes by touch

    Uterine Artery Embolization in Patients with a Large Fibroid Burden: Long-Term Clinical and MR Follow-up

    Get PDF
    Uterine artery embolization (UAE) in patients with a large fibroid burden is controversial. Anecdotal reports describe serious complications and limited clinical results. We report the long-term clinical and magnetic resonance (MR) results in a large series of women with a dominant fibroid of >10 cm and/or an uterine volume of >700 cm3. Seventy-one consecutive patients (mean age, 42.5 years; median, 40 years; range, 25–52 years) with a large fibroid burden were treated by UAE between August 2000 and April 2005. Volume reduction and infarction rate of dominant fibroid and uterus were assessed by comparing the baseline and latest follow-up MRIs. Patients were clinically followed at various time intervals after UAE with standardized questionnaires. There were no serious complications of UAE. During a mean follow-up of 48 months (median, 59 months; range, 6–106 months), 10 of 71 patients (14%) had a hysterectomy. Mean volume reduction of the fibroid and uterus was 44 and 43%. Mean infarction rate of the fibroid and overall fibroid infarction rate was 86 and 87%. In the vast majority of patients there was a substantial improvement of symptoms. Clinical results were similar in patients with a dominant fibroid >10 cm and in patients with large uterine volumes by diffuse fibroid disease. In conclusion, our results indicate that the risk of serious complications after UAE in patients with a large fibroid burden is not increased. Moreover, clinical long-term results are as good as in other patients who are treated with UAE. Therefore, a large fibroid burden should not be considered a contraindication for UAE

    A pilot study comparing the metabolic profiles of elite-level athletes from different sporting disciplines

    Get PDF
    Background: The outstanding performance of an elite athlete might be associated with changes in their blood metabolic profile. The aims of this study were to compare the blood metabolic profiles between moderate- and high-power and endurance elite athletes and to identify the potential metabolic pathways underlying these differences. Methods: Metabolic profiling of serum samples from 191 elite athletes from different sports disciplines (121 high- and 70 moderate-endurance athletes, including 44 high- and 144 moderate-power athletes), who participated in national or international sports events and tested negative for doping abuse at anti-doping laboratories, was performed using non-targeted metabolomics-based mass spectroscopy combined with ultrahigh-performance liquid chromatography. Multivariate analysis was conducted using orthogonal partial least squares discriminant analysis. Differences in metabolic levels between high- and moderate-power and endurance sports were assessed by univariate linear models. Results: Out of 743 analyzed metabolites, gamma-glutamyl amino acids were significantly reduced in both high-power and high-endurance athletes compared to moderate counterparts, indicating active glutathione cycle. High-endurance athletes exhibited significant increases in the levels of several sex hormone steroids involved in testosterone and progesterone synthesis, but decreases in diacylglycerols and ecosanoids. High-power athletes had increased levels of phospholipids and xanthine metabolites compared to moderate-power counterparts. Conclusions: This pilot data provides evidence that high-power and high-endurance athletes exhibit a distinct metabolic profile that reflects steroid biosynthesis, fatty acid metabolism, oxidative stress, and energy-related metabolites. Replication studies are warranted to confirm differences in the metabolic profiles associated with athletes’ elite performance in independent data sets, aiming ultimately for deeper understanding of the underlying biochemical processes that could be utilized as biomarkers with potential therapeutic implications

    Transkingdom Networks: A Systems Biology Approach to Identify Causal Members of Host-Microbiota Interactions

    Full text link
    Improvements in sequencing technologies and reduced experimental costs have resulted in a vast number of studies generating high-throughput data. Although the number of methods to analyze these "omics" data has also increased, computational complexity and lack of documentation hinder researchers from analyzing their high-throughput data to its true potential. In this chapter we detail our data-driven, transkingdom network (TransNet) analysis protocol to integrate and interrogate multi-omics data. This systems biology approach has allowed us to successfully identify important causal relationships between different taxonomic kingdoms (e.g. mammals and microbes) using diverse types of data

    Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting.</p> <p>Methods</p> <p>Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions), we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements.</p> <p>Results</p> <p>The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2). Wearers found the monitor straightforward to use (mean 7.5). Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%), skin irritation (37%), and bruising (7%). Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003) were more likely to report being in fair/poor health (75% vs 22%, p = 0.01) and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37). They were also more likely to remove the monitor and have inadequate numbers of measurements.</p> <p>Conclusions</p> <p>The Oscar 2 ABPM device is straightforward to use but can interfere with sleep. Commonly reported adverse effects include pain, skin irritation, and bruising. Those who tolerate the monitor poorly are more likely to report being in fair or poor health and to remove it, particularly at night.</p
    corecore