7 research outputs found

    Amphilimus-eluting stents in coronary artery disease: finally, a sweet spot for patients with diabetes mellitus?

    No full text
    Coronary artery disease (CAD) is a major cause of morbidity and mortality in patients with diabetes mellitus. In real-world registries of patients undergoing percutaneous coronary intervention (PCI), diabetic patients account for between 20 and 45% of treated of patients. Although improvements in preventive care for patients with diabetes in recent years has substantially reduced rates of cardiovascular complications, the incidence of acute myocardial infarction remains approximately five times higher in patients with versus those without diabetes mellitus.</p

    Association of interleukin 6 -174 G/C polymorphism with coronary artery disease and circulating IL-6 levels: a systematic review and meta-analysis

    No full text
    Introduction: Circulating IL-6 levels and at least one polymorphic form of IL6 gene (IL6 -174 G/C, rs1800795) have been shown to be independently associated with coronary artery disease (CAD) by several investigators. Despite more than 12 published meta-analyses on this subject, association of -174 G/C with CAD, especially amongst distinct ancestral population groups remain unclear. We, therefore, conducted a systematic review and an updated meta-analysis to comprehensively ascertain the association of IL6 -174 G/C with CAD and circulating IL-6 levels. Materials and methods: Relevant case-control/cohort studies investigating association of -174 G/C with CAD and circulating IL-6 levels were identified following a comprehensive online search. Association status for CAD was determined for the pooled sample, as well as separately for major ancestral subgroups. Association status for circulating IL-6 levels was assessed for the pooled sample, as well as separately for CAD cases and CAD free controls. Study-level odds ratios (OR) and 95% confidence intervals (CI) were pooled using random/fixed-effects model. Results: Quantitative synthesis for the CAD endpoint was performed using 55 separate qualifying studies with a collective sample size of 51,213 (19,160 cases/32,053 controls). Pooled association of -174 G/C with CAD was found to be statistically significant through dominant (OR 1.15; 95% CI 1.05-1.25, p = 0.002) as well as allelic genetic model comparisons (OR 1.13, 95% CI 1.06-1.21, p = 0.0003). This effect was largely driven by Asian and Asian Indian ancestral subgroups, which also showed significant association with CAD in both genetic model comparisons (OR range 1.29-1.53, p value range ≤ 0.02). Other ancestral subgroups failed to show any meaningful association. Circulating IL-6 levels were found to be significantly higher amongst the 'C' allele carriers in the pooled sample (Standard mean difference, SMD 0.11, 95% CI 0.01-0.22 pg/ml, p = 0.009) as well as in the CAD free control subgroup (SMD 0.10, 95% CI 0.02-0.17 pg/ml, p = 0.009), though not in the CAD case subgroup (SMD 0.17, 95% CI = - 0.02 to 0.37, p = 0.12). Conclusions: The present systematic review and meta-analysis demonstrate an overall association between IL6 -174 G/C polymorphism and CAD, which seems to be mainly driven by Asian and Asian Indian ancestral subgroups. Upregulation of plasma IL-6 levels in the 'C' allele carriers seems to be at least partly responsible for this observed association. This warrants further investigations with large, structured case-control studies especially amongst Asian and Asian Indian ancestral groups.</p

    Angiographic performance of everolimus-eluting stents for the treatment of coronary in-stent restenosis in daily practice

    No full text
    Objectives: The present study aims to analyze the angiographic anti-restenotic performance of durable polymer everolimus-eluting stents (EES) for the treatment of in-stent restenosis (ISR) in daily practice.Background: Randomized data is available supporting the use of drug-coated balloons and drug-eluting stents for the treatment of ISR; however, additional real-world data including angiographic follow-up is needed.Methods: Patients who underwent EES-implantation for the treatment of drug-eluting stent ISR and attended for a 6–8 months angiographic surveillance were analyzed. Off-line assessment of the angiograms was conducted at a central quantitative coronary angiographic core laboratory. Results: A total of 426 patients with ISR were treated with EES and had undergone angiographic follow-up. The mean age was 66.8 ± 9.9 years and 27.5% suffered from diabetes. A total of 459 lesions were treated. The diameter stenosis decreased from 64.3 ± 19.1% (preprocedural) to 12.0 ± 6.4% (postprocedural). At 6–8 months angiographic follow-up, the in-segment diameter stenosis was 38.3 ± 21.7% and the in-stent late luminal loss was 0.54 ± 0.74 mm in the treated area analysis. The rate of recurrent binary restenosis was 25.7%.Conclusions: In the setting of ISR, the angiographic anti-restenotic efficacy of stenting with EES is comparable to that observed in randomized clinical trials and less favorable than its performance in patients undergoing stenting for de novo disease.</div

    A prospective trial of a novel low-dose paclitaxel-coated balloon therapy in patients with restenosis in drug-eluting coronary stents Intracoronary Stenting and Angiographic Results: Optimizing Treatment of Drug Eluting Stent In-stent REstenosis 3A (ISAR-DESIRE 3A)

    No full text
    Objectives: We investigated the clinical efficacy of a paclitaxel-coated balloon (PCB) with a novel matrix coating and reduced drug concentration in comparison with a widely used PCB with iopromide excipient. Methods: We prospectively enrolled patients with restenosis in drug-eluting stents. All patients were treated with a novel low-dose PCB with citrate-based excipient (Agent PCB). Angiographic follow-up was scheduled at 6-8 months. Outcomes were compared against those of patients treated with iopromide excipient PCB (SeQuent Please PCB) enrolled in a trial with identical inclusion and exclusion criteria. The primary endpoint was percent diameter stenosis (%DS) at follow-up angiography. The primary hypothesis was that the investigational device would be non-inferior to the control device (ClinicalTrials.gov Identifier: NCT02367495). Results: One hundred twenty-five patients with 151 lesions were enrolled. Mean age was 68.1 ± 10.2 years, 40.8% had diabetes mellitus and 80.1% had focal morphology in-stent restenosis. Follow-up angiography data at 6-8 months was available for 102 (81.6%) patients. The Agent PCB was non-inferior to the SeQuent Please PCB in terms of the primary endpoint (38.9 ± 17.5 vs. 38.1 ± 21.5%; p non-inferiority = 0.0056). Late lumen loss was also comparable between the groups (0.35 ± 0.55 vs. 0.37 ± 0.59; p = 0.71). There was no difference between the groups in the incidence of TLR (27.7% vs. 22.1%; p = 0.31), death or myocardial infarction (4.2% vs. 4.4%; p = 0.92) or target lesion thrombosis (1.0% vs. 0.7%; p = 0.93). Conclusion: In patients with DES restenosis, angioplasty with a novel PCB with citrate-based excipient was non-inferior to PCB with iopromide excipient in terms of angiographic outcome.</p

    Design and rationale of a randomized trial of COBRA PzF stenting to REDUCE duration of triple therapy (COBRA-REDUCE)

    No full text
    Background/purpose: A coronary stent with thromboresistant and pro-healing properties such as the polymer polyzene F-coated (COBRA PzF) stent might safely allow for a very short duration of triple therapy in patients taking oral anticoagulation (OAC) who undergo coronary stenting.Methods: The COBRA-REDUCE trial is a prospective, multinational, randomized, open-label, assessor-blinded trial. A total of 996 patients at high bleeding risk because of requirement for OAC (with a vitamin K antagonist or non-vitamin K antagonist for any indication) will be randomized at sites in the United States and Europe to treatment with the COBRA-PzF stent followed by very short duration (14 days) DAPT or a Food and Drug Administration (FDA)-approved new generation drug-eluting stent followed by guideline-recommended DAPT duration (3 or 6 months). Two co-primary endpoints will be tested at 6 months: a bleeding co-primary endpoint (bleeding academic research consortium [BARC] ≥2 bleeding beyond 14 days or after hospital discharge, whichever is later [superiority hypothesis]) and a thrombo-embolic co-primary endpoint (the composite of all-cause death, myocardial infarction, definite/probable stent thrombosis or ischaemic stroke [non-inferiority hypothesis]). The trial is registered at clinicaltrials.gov (NCT02594501).Conclusion: The COBRA-REDUCE trial will determine whether coronary stenting with the COBRA PzF stent followed by 14 days of clopidogrel will reduce bleeding without increasing thrombo-embolic events compared with FDA-approved DES followed by 3-6 months clopidogrel in patients taking OAC and aspirin.</p

    10-Year outcomes from a randomized trial of polymer-free versus durable polymer drug-eluting coronary stents

    No full text
    Background: Outcome data after extended long-term follow-up of patients with coronary artery disease treated with drug-eluting stents (DES) in randomized clinical trials are scant.Objectives: Performance differences among devices may be expected to emerge over time depending on whether stenting is done with polymer-free or durable polymer DES. This study assessed the 10-year outcomes of patients enrolled in the ISAR-TEST-5 (Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus-Eluting Stents) trial.Methods: A total of 3,002 patients were randomized to treatment with either polymer-free sirolimus- and probucol-eluting stents (n = 2,002) or durable polymer zotarolimus-eluting stents (n = 1,000). The primary endpoint was the composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization (a device-oriented composite endpoint [DOCE]). Additional endpoints of interest were the patient-oriented composite endpoint (POCE), including all-cause death, any myocardial infarction, or any revascularization; individual components of the composite endpoints; and definite or probable stent thrombosis.Results: The median age of the patients at randomization was 67.8 years. At 10 years, 63.9% of patients were alive. The rates of DOCE and POCE were high in both groups with no difference in the incidence between polymer-free sirolimus- and probucol-eluting stents and durable polymer zotarolimus-eluting stents (DOCE: 43.8% vs. 43.0%, respectively; hazard ratio: 1.01; 95% confidence interval [CI]: 0.89 to 1.14; p = 0.90; POCE: 66.2% vs. 67.7%, respectively; hazard ratio: 0.94; 95% CI: 0.86 to 1.04; p = 0.22). The rates of the individual components of the composite endpoints were comparable in both groups. The incidence of definite/probable stent thrombosis over 10 years was low and comparable in both groups (1.6% vs. 1.9%; hazard ratio: 0.85; 95% CI: 0.46 to 1.54; p = 0.58).Conclusions: At 10 years, there were no measurable differences in outcomes between patients treated with polymer-free versus durable polymer DES. The incidence of stent thrombosis was low and comparable in both groups. High overall adverse clinical event rates were observed during extended follow-up. (Test Efficacy of Sirolimus- and Probucol-Eluting Versus Zotarolimus-Eluting Stents [ISAR-TEST-5]; NCT00598533).</p

    Optical coherence tomography tissue coverage and characterization at six months after implantation of bioresorbable scaffolds versus conventional everolimus eluting stents in the ISAR-Absorb MI trial

    No full text
    Purpose: Data regarding vessel healing by optical coherence tomography (OCT) after everolimus-eluting bioresorbable scaffolds (BRS) or everolimus-eluting metallic stent (EES) implantation in acute myocardial infarction (AMI) patients is scarce. We compared OCT findings after BRS or EES implantation in patients with AMI enrolled in a randomized trial.Methods: In ISAR-Absorb MI, AMI patients were randomized to BRS or EES implantation, with 6-8 month angiographic follow-up. This analysis includes patients who underwent OCT during surveillance angiography. Tissue characterization was done using grey-scale signal intensity analysis. The association between OCT findings and target lesion failure (TLF) at 2 years was investigated.Results: OCT was analyzed in 103 patients (2237 frames, 19,827 struts) at a median of 216 days post-implantation. Of these, 70 were treated with BRS versus 32 with EES. Pre-(92.8 vs. 68.7%, p = 0.002) and post-dilation (51.4 vs. 12.5%, p Conclusions: In selected patients who underwent OCT surveillance 6-8 months after coronary intervention for AMI with differing implantation characteristics depending on the device type used, vessel healing was more advanced in BRS compared with EES, particularly in the STEMI subgroup.</div
    corecore