22 research outputs found
Recommended from our members
A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method
A portable system has been assembled that is capable of measuring the subcriticality of fissile materials using the /sup 252/CF-source-driven neutron noise analysis method. The measurement system consists of a parallel-plate ionization chamber containing /sup 252/CF, two /sup 3/He proportional counters with their associated electronics, and a small computer containing anti-aliasing filters and A/D convertors. The system Fourier analyzes the digitized data and forms the appropriate auto and cross-power spectral densities. These spectra are used to form a ratio of spectral densities, G/sub 12/G/sub 13//G/sub 11/G/sub 23/, where 1 refers to the ionization chamber, and 2 and 3 refer to the /sup 3/He counters, from which subcriticality can be determined. The chamber and detectors are located appropriately near the fissile material. The system is capable of sampling signals at rates of up to 80 kHz and processing these data at rates of 2 kHz to form the appropriate spectra. The presently configured system is a two-channel system, hence the measurement of G/sub 12/, G/sub 13/, and G/sub 23/ must be done sequentially before the ratio of spectral densities is obtained. Future improvements of the system will allow simultaneous measurement of all spectra and will further reduce size, thereby enhancing portability. This measurement system can provide reliable, cost effective, and convenient determination of the subcriticality of a wide variety of fissile materials and moderators
Recommended from our members
Pulmonary macrophage and epithelial cells
Separate abstracts were prepared for the 41 papers presented at the conference. Abstracts of two papers have appeared in previous issues of Energy Research Abstracts. (HLW
The First VERITAS Telescope
The first atmospheric Cherenkov telescope of VERITAS (the Very Energetic
Radiation Imaging Telescope Array System) has been in operation since February
2005. We present here a technical description of the instrument and a summary
of its performance. The calibration methods are described, along with the
results of Monte Carlo simulations of the telescope and comparisons between
real and simulated data. The analysis of TeV -ray observations of the
Crab Nebula, including the reconstructed energy spectrum, is shown to give
results consistent with earlier measurements. The telescope is operating as
expected and has met or exceeded all design specifications.Comment: Accepted by Astroparticle Physic
Recommended from our members
General Models for Assessing Hazards Aircraft Pose to Surface Facilities
This paper derives formulas for estimating the frequency of accidental aircraft crashes into surface facilities. Objects unintentionally dropped from aircraft are also considered. The approach allows the facility to be well within the flight area; inside the flight area, but close to the edge; or completely outside the flight area
Recommended from our members
Health physics research reactor reference dosimetry
Reference neutron dosimetry is developed for the Health Physics Research Reactor (HPRR) in the new operational configuration directly above its storage pit. This operational change was physically made early in CY 1985. The new reference dosimetry considered in this document is referred to as the 1986 HPRR reference dosimetry and it replaces any and all HPRR reference documents or papers issued prior to 1986. Reference dosimetry is developed for the unshielded HPRR as well as for the reactor with each of five different shield types and configurations. The reference dosimetry is presented in terms of three different dose and six different dose equivalent reporting conventions. These reporting conventions cover most of those in current use by dosimetrists worldwide. In addition to the reference neutron dosimetry, this document contains other useful dosimetry-related data for the HPRR in its new configuration. These data include dose-distance measurements and calculations, gamma dose measurements, neutron-to-gamma ratios, ''9-to-3 inch'' ratios, threshold detector unit measurements, 56-group neutron energy spectra, sulfur fluence measurements, and details concerning HPRR shields. 26 refs., 11 figs., 31 tabs
Recommended from our members
A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method
A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the /sup 252/Cf-source-driven neutron noise analysis method. 8 refs
Recommended from our members
Empirical correlation of residual gamma radiation resulting from operation of the Health Physics Research Reactor
An empirical equation has been developed which gives gamma dose equivalent rate as a function of time, distance, and fission yield after a pulsed operation of Oak Ridge National Laboratory's (ORNL) unshielded Health Physics Research Reactor (HPRR). A related expression which is applicable to steady-state reactor operation has been mathematically derived from the aforementioned empirical equation. The two relations can be used to predict the gamma dose equivalent rate to within 25% for times between 1 minute and 90 minutes after reactor shutdown. Similar agreement is expected for up to several days. In most cases the relations are expected to overestimate the gamma dose equivalent rate. 5 refs., 4 figs., 1 tab
Recommended from our members
CATEGORIZATION OF EVENT SEQUENCES FOR LICENSE APPLICATION
The purposes of this analysis are: (1) Categorize (as Category 1, Category 2, or Beyond Category 2) internal event sequences that may occur before permanent closure of the repository at Yucca Mountain. (2) Categorize external event sequences that may occur before permanent closure of the repository at Yucca Mountain. This includes examining DBGM-1 seismic classifications and upgrading to DBGM-2, if appropriate, to ensure Beyond Category 2 categorization. (3) State the design and operational requirements that are invoked to make the categorization assignments valid. (4) Indicate the amount of material put at risk by Category 1 and Category 2 event sequences. (5) Estimate frequencies of Category 1 event sequences at the maximum capacity and receipt rate of the repository. (6) Distinguish occurrences associated with normal operations from event sequences. It is beyond the scope of the analysis to propose design requirements that may be required to control radiological exposure associated with normal operations. (7) Provide a convenient compilation of the results of the analysis in tabular form. The results of this analysis are used as inputs to the consequence analyses in an iterative design process that is depicted in Figure 1. Categorization of event sequences for permanent retrieval of waste from the repository is beyond the scope of this analysis. Cleanup activities that take place after an event sequence and other responses to abnormal events are also beyond the scope of the analysis
Recommended from our members
Subcritical measurements using the /sup 252/Cf source-driven neutron noise analysis method
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of fission neutrons; and the second and third detectors that are placed in or near the system containing fissile material and serve to detect particles from the fission chain multiplication process. 9 refs
Recommended from our members
Dynamic subcriticality measurements using the CF neutron noise method: Videotape
The capability to measure the subcriticality for a multiplying system with k-effective values as low as 0.3 was demonstrated for measurement times of approximately 10 s; the measured k-effective values obtained do not depend on the speed with which the solution height is changed or on whether the tank is filling or draining. As in previous experiments, the low-frequency ratios of spectral densities are all that are needed to obtain the k-effective value. This method's effectiveness for systems where conditions are changing with time as demonstrated, probably exceeds the dynamic requirements for most nuclear fuel plant processing applications. The calculated k-effective values using the KENO code and Hansen-Roach cross-sections compare well with the experimental values. Before the dynamic capability of the method can be considered fully explored, additional dynamic experiments are required for other geometries and fuel concentrations