15 research outputs found

    Children, Gillick competency and consent for involvement in research

    No full text
    This paper looks at the issue of consent from children and whether the test of Gillick competency, applied in medical and healthcare practice, ought to extend to participation in research. It is argued that the relatively broad usage of the test of Gillick competency in the medical context should not be considered applicable for use in research. The question of who would and could determine Gillick competency in research raises further concerns relating to the training of the researcher to make such a decision as well as to the obvious issue of the researcher's personal interest in the project and possibility of benefiting from the outcome. These could affect the judgment of Gillick competency if the researcher is charged with making this decision. The above notwithstanding, there are two exceptional research situations in which Gillick competency might be legitimately applied: (1) when the research is likely to generate significant advantages for the participants while exposing them to relatively minor risks, and (2) when it is likely to generate great societal benefit, pose minimal risks for the participants and yet raise parental objection. In both cases, to ensure that autonomy is genuinely respected and to protect against personal interest, Gillick competency should be assessed by an individual who has no interest or involvement in the research

    Modeling internal stress distributions in the human lens: Can opponent theories coexist?

    No full text
    The effects of material properties and equatorial stretching forces on the stress distribution and shape profile of human lenses were investigated to see whether support could be found for either or both current theories of accommodation. Finite element analysis was used to create models using shape parameters and material properties from published data. Models were constructed for two lenses of different ages. Material properties were varied to show differences between models with a single elastic modulus and those with different moduli for the cortex and the nucleus. Two levels of stretching forces were applied at the equator. Comparisons between experimental and model profiles were made, and stress distribution patterns were constructed. In all models, stretching produces a flattening in the peripheral curvature of the lens. In the younger lens, model and experimental results show that central curvature at some points is steeper for stretched than for unstretched profiles. In the older lens, gradients are flatter at all central points for stretched model and experimental profiles compared to the unstretched profile. In all models, there is a region of higher stress distribution within the lens that corresponds with the position of an inflection point that appears on the anterior surface and, in the older lens, also on the posterior surface. The results show that equatorial stretching forces can produce shape changes in support of both current theories of accommodation depending on the lens age, shape, and applied force

    The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye

    No full text
    AIM: To measure corneal and scleral radii of curvature in response to intraocular pressure (IOP). METHODS: Using digital photographic profile images of 16 fresh porcine eyes, the curvatures of the cornea and sclera were determined in response to five consecutive incremental 100 μl saline intravitreal injections. IOP was measured and ocular rigidity calculated. Elastic moduli of the cornea and sclera were estimated. RESULTS: Intraocular pressure and the radius of curvature of the sclera increased linearly with increasing volume. There was no statistical change in corneal curvature. The elasticity of the cornea and sclera was constant during the 15–50 mm Hg increase in IOP. The estimated range of the elastic moduli of the cornea and sclera were, respectively 0.07–0.29 MPa and 0.2 MPa to 0.5 MPa. The scleral rigidity ranged from 0.0017 to 0.0022. CONCLUSIONS: The elastic moduli of the cornea and sclera are independent of IOP. The modulus of elasticity of the sclera is higher than that of the cornea. Elevation of IOP changes the curvature of the sclera but not that of the cornea. Porcine scleral rigidity is similar to human scleral rigidity. Scleral curvature could be a novel method for measuring IOP
    corecore