3,358 research outputs found
First results from an aging test of a prototype RPC for the LHCb Muon System
Recent results of an aging test performed at the CERN Gamma Irradiation
Facility on a single--gap RPC prototype developed for the LHCb Muon System are
presented. The results are based on an accumulated charge of about 0.45
C/cm, corresponding to about 4 years of LHCb running at the highest
background rate. The performance of the chamber has been studied under several
photon flux values exploiting a muon beam. A degradation of the rate capability
above 1 kHz/cm is observed, which can be correlated to a sizeable increase
of resistivity of the chamber plates. An increase of the chamber dark current
is also observed. The chamber performance is found to fulfill the LHCb
operation requirements.Comment: 6 pages, 9 figures, presented at the International Workshop on Aging
Phenomena in Gaseous Detectors'', DESY-Hamburg (Germany), October 200
Preliminary results of an aging test of RPC chambers for the LHCb Muon System
The preliminary results of an aging test performed at the CERN Gamma
Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon
System are presented. The results are based on an accumulated charge density of
0.42 C/cm^2, corresponding to about 4 years of LHCb running at the highest
background rate. We observe a rise in the dark current and noise measured with
source off. The current drawn with source on steadily decreased, possibly
indicating an increase of resistivity of the chamber plates. The performance of
the chamber, studied with a muon beam under several photon flux values, is
found to still fulfill the LHCb operation requirements.Comment: 4 pages, 6 figures, presented at RPC2001, VIth Workshop on Resistive
Plate Chambers and Related Detectors, November 26-27 2001, Coimbra, Portuga
EuroGammaS gamma characterisation system for ELI-NP-GBS: The nuclear resonance scattering technique
A Gamma Beam Characterisation System has been designed by the EuroGammaS association for thecommissioning and development of the Extreme Light Infrastructure-Nuclear Physics Gamma Beam System(ELI-NP-GBS) to be installed in Magurele, Romania. The characterisation system consists of four elements: aCompton spectrometer, a sampling calorimeter, a nuclear resonant scattering spectrometer (NRSS) and a beamprofile imager. In this paper, the nuclear resonant scattering spectrometer system, designed to perform anabsolute energy calibration for the gamma beam, will be describe
Performance of the LHCb muon system with cosmic rays
The LHCb Muon system performance is presented using cosmic ray events
collected in 2009. These events allowed to test and optimize the detector
configuration before the LHC start. The space and time alignment and the
measurement of chamber efficiency, time resolution and cluster size are
described in detail. The results are in agreement with the expected detector
performance.Comment: Submitted to JINST and accepte
Performance of the Muon Identification at LHCb
The performance of the muon identification in LHCb is extracted from data
using muons and hadrons produced in J/\psi->\mu\mu, \Lambda->p\pi and
D^{\star}->\pi D0(K\pi) decays. The muon identification procedure is based on
the pattern of hits in the muon chambers. A momentum dependent binary
requirement is used to reduce the probability of hadrons to be misidentified as
muons to the level of 1%, keeping the muon efficiency in the range of 95-98%.
As further refinement, a likelihood is built for the muon and non-muon
hypotheses. Adding a requirement on this likelihood that provides a total muon
efficiency at the level of 93%, the hadron misidentification rates are below
0.6%.Comment: 17 pages, 10 figure
Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency
A method is described which allows to deduce the dead-time of the front-end
electronics of the LHCb muon detector from a series of measurements performed
at different luminosities at a bunch-crossing rate of 20 MHz. The measured
values of the dead-time range from 70 ns to 100 ns. These results allow to
estimate the performance of the muon detector at the future bunch-crossing rate
of 40 MHz and at higher luminosity
Performance of the LHCb muon system
The performance of the LHCb Muon system and its stability across the full
2010 data taking with LHC running at ps = 7 TeV energy is studied. The
optimization of the detector setting and the time calibration performed with
the first collisions delivered by LHC is described. Particle rates, measured
for the wide range of luminosities and beam operation conditions experienced
during the run, are compared with the values expected from simulation. The
space and time alignment of the detectors, chamber efficiency, time resolution
and cluster size are evaluated. The detector performance is found to be as
expected from specifications or better. Notably the overall efficiency is well
above the design requirementsComment: JINST_015P_1112 201
A Laser Based Instrument for MWPC Wire Tension Measurement
A fast and simple method for the measurement of the mechanical tension of wires of Multi Wires Proportional Chambers (MWPCs) is described. The system is based on commercial components and does not require any electrical connection to the wires or electric or magnetic field. It has been developed for the quality control of MWPCs of the Muon Detector of the LHCb experiment in construction at CERN. The system allows a measurement of the wire tension with a precision better than 0.5% within 3-4 seconds per wir
Differential branching fraction and angular analysis of the decay B0âKâ0ÎŒ+ÎŒâ
The angular distribution and differential branching fraction of the decay B 0â K â0 ÎŒ + ÎŒ â are studied using a data sample, collected by the LHCb experiment in pp collisions at sâ=7 TeV, corresponding to an integrated luminosity of 1.0 fbâ1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions
Study of Spin and Decay-Plane Correlations of W Bosons in the e+e- -> W+W- Process at LEP
Data collected at LEP at centre-of-mass energies \sqrt(s) = 189 - 209 GeV are
used to study correlations of the spin of W bosons using e+e- -> W+W- -> lnqq~
events. Spin correlations are favoured by data, and found to agree with the
Standard Model predictions. In addition, correlations between the W-boson decay
planes are studied in e+e- -> W+W- -> lnqq~ and e+e- -> W+W- -> qq~qq~ events.
Decay-plane correlations, consistent with zero and with the Standard Model
predictions, are measured
- âŠ