    A Rapid Assessment of the Quality of Neonatal Healthcare in Kilimanjaro Region, Northeast Tanzania.

    Get PDF
    While child mortality is declining in Africa there has been no evidence of a comparable reduction in neonatal mortality. The quality of inpatient neonatal care is likely a contributing factor but data from resource limited settings are few. The objective of this study was to assess the quality of neonatal care in the district hospitals of the Kilimanjaro region of Tanzania. Clinical records were reviewed for ill or premature neonates admitted to 13 inpatient health facilities in the Kilimanjaro region; staffing and equipment levels were also assessed. Among the 82 neonates reviewed, key health information was missing from a substantial proportion of records: on maternal antenatal cards, blood group was recorded for 52 (63.4%) mothers, Rhesus (Rh) factor for 39 (47.6%), VDRL for 59 (71.9%) and HIV status for 77 (93.1%). From neonatal clinical records, heart rate was recorded for3 (3.7%) neonates, respiratory rate in 14, (17.1%) and temperature in 33 (40.2%). None of 13 facilities had a functioning premature unit despite calculated gestational age <36 weeks in 45.6% of evaluated neonates. Intravenous fluids and oxygen were available in 9 out of 13 of facilities, while antibiotics and essential basic equipment were available in more than two thirds. Medication dosing errors were common; under-dosage for ampicillin, gentamicin and cloxacillin was found in 44.0%, 37.9% and 50% of cases, respectively, while over-dosage was found in 20.0%, 24.2% and 19.9%, respectively. Physician or assistant physician staffing levels by the WHO indicator levels (WISN) were generally low. Key aspects of neonatal care were found to be poorly documented or incorrectly implemented in this appraisal of neonatal care in Kilimanjaro. Efforts towards quality assurance and enhanced motivation of staff may improve outcomes for this vulnerable group

    Culture-negative bivalvular endocarditis with myocardial destruction in a patient with systemic lupus erythematosus: a case report

    Get PDF
    Culture-negative endocarditis has long been associated with systemic lupus erythematosus, but is usually asymptomatic or involves a single valve. We present a patient with destructive culture-negative endocarditis that remains without a microbial etiology despite an exhaustive workup using advanced diagnostic techniques in a patient with systemic lupus erythematosus

    Embolic stroke complicating Staphylococcus aureus endocarditis circumstantially linked to rectal trauma from foreign body: a first case report

    Get PDF
    BACKGROUND: Diagnostic and therapeutic instrumentation of the lower gastrointestinal tract has been reported to result in bacteremia and endocarditis. No such case has been reported in persons with a history of rectal foreign body insertion despite its potential for greater trauma. CASE PRESENTATION: A 58-year-old male was admitted with confusion and inability to speak. His past history was notable for hospitalization to extract a retained plastic soda bottle from the rectosigmoid two years prior. On examination, he was febrile, tachycardic and hypotensive. There was an apical pansystolic murmur on cardiac examination. He had a mixed receptive and expressive aphasia, and a right hemiparesis. On rectal examination he had perianal erythema and diminished sphincter tone. Magnetic resonance imaging of the brain showed infarction of the occipital and frontal lobes. Transesophageal Echocardiography of the heart revealed vegetations on the mitral valve. All of his blood culture bottles grew methicillin sensitive Staphylococcus aureus. He was successfully treated for bacterial endocarditis with intravenous nafcillin and gentamicin. The rectum is frequently colonized by Staphylococcus aureus and trauma to its mucosa can lead to bacteremia and endocarditis with this organism. In the absence of corroborative evidence such as presented here, it is difficult to make a correlation between staphylococcal endocarditis and anorectal foreign body insertion due to patients being less than forthcoming CONCLUSION: There is a potential risk of staphylococcal bacteremia and endocarditis with rectal foreign body insertion. Further studies are needed to explore this finding. Detailed sexual history and patient counseling should be made a part of routine primary care

    Etiology of Severe Non-malaria Febrile Illness in Northern Tanzania: A Prospective Cohort Study.

    Get PDF
    The syndrome of fever is a commonly presenting complaint among persons seeking healthcare in low-resource areas, yet the public health community has not approached fever in a comprehensive manner. In many areas, malaria is over-diagnosed, and patients without malaria have poor outcomes. We prospectively studied a cohort of 870 pediatric and adult febrile admissions to two hospitals in northern Tanzania over the period of one year using conventional standard diagnostic tests to establish fever etiology. Malaria was the clinical diagnosis for 528 (60.7%), but was the actual cause of fever in only 14 (1.6%). By contrast, bacterial, mycobacterial, and fungal bloodstream infections accounted for 85 (9.8%), 14 (1.6%), and 25 (2.9%) febrile admissions, respectively. Acute bacterial zoonoses were identified among 118 (26.2%) of febrile admissions; 16 (13.6%) had brucellosis, 40 (33.9%) leptospirosis, 24 (20.3%) had Q fever, 36 (30.5%) had spotted fever group rickettsioses, and 2 (1.8%) had typhus group rickettsioses. In addition, 55 (7.9%) participants had a confirmed acute arbovirus infection, all due to chikungunya. No patient had a bacterial zoonosis or an arbovirus infection included in the admission differential diagnosis. Malaria was uncommon and over-diagnosed, whereas invasive infections were underappreciated. Bacterial zoonoses and arbovirus infections were highly prevalent yet overlooked. An integrated approach to the syndrome of fever in resource-limited areas is needed to improve patient outcomes and to rationally target disease control efforts

    Evaluation of genotypic and phenotypic methods for differentiation of the members of the Anginosus group streptococci

    Get PDF
    The terminology and classification of the Anginosus group streptococci has been inconsistent. We tested the utility of 16S rRNA gene and tuf gene sequencing and conventional biochemical tests for the reliable differentiation of the Anginosus group streptococci. Biochemical testing included Rapid ID 32 Strep, API Strep, Fluo-Card Milleri, Wee-tabs, and Lancefield antigen typing. Altogether, 61 Anginosus group isolates from skin and soft tissue infections and four reference strains were included. Our results showed a good agreement between 16S rRNA gene and tuf gene sequencing. Using the full sequence was less discriminatory than using the first part of the 16S rRNA gene. The three species could not be separated with the API 20 Strep test. Streptococcus intermedius could be differentiated from the other two species by β-galactosidase (ONPG) and β-N-acetyl-glucosaminidase reactions. Rapid ID 32 Strep β-glucosidase reaction was useful in separating S. anginosus strains from S. constellatus. In conclusion, both 16S rRNA gene and tuf gene sequencing can be used for the reliable identification of the Anginosus group streptococci. S. intermedius can be readily differentiated from the other two species by phenotypic tests; however, 16S rRNA gene or tuf gene sequencing may be needed for separating some strains of S. constellatus from S. anginosus

    Accuracy of Malaria Rapid Diagnostic Tests in Community Studies and their Impact on Treatment of Malaria in an Area with Declining Malaria Burden in North-Eastern Tanzania.

    Get PDF
    Despite some problems related to accuracy and applicability of malaria rapid diagnostic tests (RDTs), they are currently the best option in areas with limited laboratory services for improving case management through parasitological diagnosis and reducing over-treatment. This study was conducted in areas with declining malaria burden to assess; 1) the accuracy of RDTs when used at different community settings, 2) the impact of using RDTs on anti-malarial dispensing by community-owned resource persons (CORPs) and 3) adherence of CORPs to treatment guidelines by providing treatment based on RDT results. Data were obtained from: 1) a longitudinal study of passive case detection of fevers using CORPs in six villages in Korogwe; and 2) cross-sectional surveys (CSS) in six villages of Korogwe and Muheza districts, north-eastern, Tanzania. Performance of RDTs was compared with microscopy as a gold standard, and factors affecting their accuracy were explored using a multivariate logistic regression model. Overall sensitivity and specificity of RDTs in the longitudinal study (of 23,793 febrile cases; 18,154 with microscopy and RDTs results) were 88.6% and 88.2%, respectively. In the CSS, the sensitivity was significantly lower (63.4%; χ2=367.7, p<0.001), while the specificity was significantly higher (94.3%; χ2=143.1, p<0.001) when compared to the longitudinal study. As determinants of sensitivity of RDTs in both studies, parasite density of<200 asexual parasites/μl was significantly associated with high risk of false negative RDTs (OR≥16.60, p<0.001), while the risk of false negative test was significantly lower among cases with fever (axillary temperature ≥37.5 °C) (OR≤0.63, p≤0.027). The risk of false positive RDT (as a determinant of specificity) was significantly higher in cases with fever compared to afebrile cases (OR≥2.40, p<0.001). Using RDTs reduced anti-malarials dispensing from 98.9% to 32.1% in cases aged ≥5 years. Although RDTs had low sensitivity and specificity, which varied widely depending on fever and parasite density, using RDTs reduced over-treatment with anti-malarials significantly. Thus, with declining malaria prevalence, RDTs will potentially identify majority of febrile cases with parasites and lead to improved management of malaria and non-malaria fevers

    Good Clinical Laboratory Practices Improved Proficiency Testing Performance at Clinical Trials Centers in Ghana and Burkina Faso

    Get PDF
    BACKGROUND: The recent drive towards accreditation of clinical laboratories in Africa by the World Health Organization-Regional Office for Africa (WHO-AFRO) and the U.S Government is a historic step to strengthen health systems, provide better results for patients and an improved quality of results for clinical trials. Enrollment in approved proficiency testing (PT) programs and maintenance of satisfactory performance is vital in the process of accreditation. Passing proficiency testing surveys has posed a great challenge to many laboratories across sub-Saharan Africa. Our study was aimed at identifying the causes of unsatisfactory PT results in clinical research laboratories conducting or planning to conduct malaria vaccine trials sponsored by the National Institutes of Health (NIH). METHODOLOGY: PT reports for 2009 and 2010 from the College of American Pathologists (CAP) for the laboratories were reviewed as part of the process. Errors accounting for unsatisfactory results were classified into clerical, methodological, technical, problem with PT materials, and random errors. A training program on good clinical laboratory practices (GCLP) was developed for each center to address areas for improvement. RESULTS: The major cause of PT failure in the four centers was methodological. The application of GCLP improved the success rate in the PT surveys from 58% in 2009 to 88% in 2010. It also decreased the error rate on PT by 35%. CONCLUSION: A previous report from the CAP- PT participating laboratories indicated that the major causes of error were clerical. These types of errors were predominantly made in laboratories in the US, with much more experience in quality control, and varied significantly from what we found. In our centers in sub-Saharan Africa, methodological errors, and not clerical errors, accounted for the vast majority of errors. A process was started for continuous improvement which has decreased methodological errors by 35%, but more improvement is needed

    Data and Image Transfer Using Mobile Phones to Strengthen Microscopy-Based Diagnostic Services in Low and Middle Income Country Laboratories

    Get PDF
    Background: The emerging market of mobile phone technology and its use in the health sector is rapidly expanding and connecting even the most remote areas of world. Distributing diagnostic images over the mobile network for knowledge sharing, feedback or quality control is a logical innovation. Objective: To determine the feasibility of using mobile phones for capturing microscopy images and transferring these to a central database for assessment, feedback and educational purposes. Methods: A feasibility study was carried out in Uganda. Images of microscopy samples were taken using a prototype connector that could fix a variety of mobile phones to a microscope. An Information Technology (IT) platform was set up for data transfer from a mobile phone to a website, including feedback by text messaging to the end user. Results: Clear images were captured using mobile phone cameras of 2 megapixels (MP) up to 5MP. Images were sent by mobile Internet to a website where they were visualized and feedback could be provided to the sender by means of text message. Conclusion: The process of capturing microscopy images on mobile phones, relaying them to a central review website and feeding back to the sender is feasible and of potential benefit in resource poor settings. Even though the system needs furthe

    A Novel Campylobacter jejuni Sequence Type from a Culture-Negative Patient in The Gambia

    Get PDF
    The introduction of molecular diagnostic methods is crucial for improved understanding of the aetiology and epidemiology of bacterial infections in communities in resource poor settings. A blood sample from a 7 month old patient diagnosed with malaria in 2001 in a Gambian outpatient clinic was reported as culture negative after it was subjected to traditional bacterial culture protocols. We re-addressed the analysis of the blood sample from this case more recently (after 6.5 years in archival storage) in pilot work establishing 16S rRNA PCR in our molecular laboratory. Initial 16S rRNA PCR results confirmed the presence of bacterial DNA in the sample. 16S rRNA sequence analysis identified the organism as Campylobacter spp. In light of the molecular evidence we successfully grew the organism using appropriate culture conditions and subsequently biochemically confirmed that the isolate was Campylobacter jejuni. PCR and DNA sequencing of a set of seven C. jejuni housekeeping genes and in silico Multilocus Sequence Typing (MLST) analysis revealed that the isolate exhibits a novel sequence type (ST) of C. jejuni (ST 2928) and belongs to ST-443 clonal complex. This study demonstrates the potential for molecular tools to enhance the diagnosis of bacterial infections, which remain a major killer globally, not least in children in the developing world. Improvements in diagnostics are needed, and will be important not only for sick individuals but also for populations, where better measures of disease burden will contribute significantly to the improvement of public health policy
    corecore