740 research outputs found

    Evidence for a gene influencing heart rate on chromosome 5p13-14 in a meta-analysis of genome-wide scans from the NHLBI Family Blood Pressure Program

    Get PDF
    BACKGROUND: Elevated resting heart rate has been shown in multiple studies to be a strong predictor of cardiovascular disease. Previous family studies have shown a significant heritable component to heart rate with several groups conducting genomic linkage scans to identify quantitative trait loci. METHODS: We performed a genome-wide linkage scan to identify quantitative trait loci influencing resting heart rate among 3,282 Caucasians and 3,989 African-Americans in three independent networks comprising the Family Blood Pressure Program (FBPP) using 368 microsatellite markers. Mean heart rate measurements were used in a regression model including covariates for age, body mass index, pack-years, currently drinking alcohol (yes/no), hypertension status and medication usage to create a standardized residual for each gender/ethnic group within each study network. This residual was used in a nonparametric variance component model to generate a LOD score and a corresponding P value for each ethnic group within each study network. P values from each ethnic group and study network were merged using an adjusted Fisher's combining P values method and the resulting P values were converted to LOD scores. The entire analysis was redone after individuals currently taking beta-blocker medication were removed. RESULTS: We identified significant evidence of linkage (LOD = 4.62) to chromosome 10 near 142.78 cM in the Caucasian group of HyperGEN. Between race and network groups we identified a LOD score of 1.86 on chromosome 5 (between 39.99 and 45.34 cM) in African-Americans in the GENOA network and the same region produced a LOD score of 1.12 among Caucasians within a different network (HyperGEN). Combining all network and race groups we identified a LOD score of 1.92 (P = 0.0013) on chromosome 5p13-14. We assessed heterogeneity for this locus between networks and ethnic groups and found significant evidence for low heterogeneity (P ≤ 0.05). CONCLUSION: We found replication (LOD > 1) between ethnic groups and between study networks with low heterogeneity on chromosome 5p13-14 suggesting that a gene in this region influences resting heart rate

    Universal field equations for metric-affine theories of gravity

    Get PDF
    We show that almost all metric--affine theories of gravity yield Einstein equations with a non--null cosmological constant Λ\Lambda. Under certain circumstances and for any dimension, it is also possible to incorporate a Weyl vector field WμW_\mu and therefore the presence of an anisotropy. The viability of these field equations is discussed in view of recent astrophysical observations.Comment: 13 pages. This is a copy of the published paper. We are posting it here because of the increasing interest in f(R) theories of gravit

    Validation protocols for blood pressure measuring devices: the impact of the European Society of Hypertension International Protocol and the development of a Universal Standard

    Get PDF
    In the last three decades protocols for the validation of blood pressure measuring devices have been developed by the US Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League, the European Society of Hypertension Working Group on blood pressure Monitoring and the International Organization for Standardization. The European Society of Hypertension International Protocol required much smaller sample size than the other protocols, aiming to reduce the time, resources and cost of validation studies and thereby increase the number of validated devices. Given its specifications, the European Society of Hypertension International Protocol was adequate for ‘high- and low-accuracy’ devices, yet assessment of ‘moderate accuracy’ devices had high uncertainty with resultant high rate of device failure. Thus, devices validated using the European Society of Hypertension International Protocol should be considered to be as accurate as those validated with the previous Association for the Advancement of Medical Instrumentation or British Hypertension Society protocols. However, the European Society of Hypertension International Protocol did not allow subgroup evaluation (arm sizes, special populations, etc). The mission of the European Society of Hypertension International Protocol to promote the concept of validation has been well achieved, as almost double studies have been published using it than all the other protocols together. However, the maintenance of different validation protocols is confusing and therefore experts from the Association for the Advancement of Medical Instrumentation, European Society of Hypertension International Protocol and International Organization for Standardization have now developed the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) as the recommended 21st-century procedure for worldwide application. The European Society of Hypertension Working Group has published a practical guide for using the Universal Standard. It is in the interests of all scientific bodies to propagate the Universal Standard and ensure its wide implementation

    The Hamiltonian of Einstein affine-metric formulation of General Relativity

    Full text link
    It is shown that the Hamiltonian of the Einstein affine-metric (first order) formulation of General Relativity (GR) leads to a constraint structure that allows the restoration of its unique gauge invariance, four-diffeomorphism, without the need of any field dependent redefinition of gauge parameters as is the case for the second order formulation. In the second order formulation of ADM gravity the need for such a redefinition is the result of the non-canonical change of variables [arXiv: 0809.0097]. For the first order formulation, the necessity of such a redefinition "to correspond to diffeomorphism invariance" (reported by Ghalati [arXiv: 0901.3344]) is just an artifact of using the Henneaux-Teitelboim-Zanelli ansatz [Nucl. Phys. B 332 (1990) 169], which is sensitive to the choice of linear combination of tertiary constraints. This ansatz cannot be used as an algorithm for finding a gauge invariance, which is a unique property of a physical system, and it should not be affected by different choices of linear combinations of non-primary first class constraints. The algorithm of Castellani [Ann. Phys. 143 (1982) 357] is free from such a deficiency and it leads directly to four-diffeomorphism invariance for first, as well as for second order Hamiltonian formulations of GR. The distinct role of primary first class constraints, the effect of considering different linear combinations of constraints, the canonical transformations of phase-space variables, and their interplay are discussed in some detail for Hamiltonians of the second and first order formulations of metric GR. The first order formulation of Einstein-Cartan theory, which is the classical background of Loop Quantum Gravity, is also discussed.Comment: 74 page

    Relationship between blood pressure measurements recorded on patients' charts in family physicians' offices and subsequent 24 hour ambulatory blood pressure monitoring

    Get PDF
    BACKGROUND: In most western countries 20% of adults have hypertension. Reports in the literature suggest that from 31 to 86% of treated patients are not at recommended target levels. However it is important to consider how we are determining whether targets are unmet and the degree to which they are unmet. Our underlying hypothesis is that white coat effect is partially responsible for the reported low rates of control of hypertension by primary care practitioners. METHODS: The study population consists of 1142 patients who are being assessed for enrolment in two community-based randomized controlled trials. Patients must have essential hypertension, be on antihypertensive medication, and must not have met their blood pressure targets. We are reporting on the proportion of patients who have not achieved target, and the degree to which they have not achieved their target. We also report on the mean daytime blood pressures on 24 hour ABPM and compare these to mean blood pressures found on the patients' charts. RESULTS: We identified 3284 patient charts of patients with hypertension. Of these, 1142 were determined to be "out of control" (did not achieve target) and 436 agreed to undergo 24 hour ABPM for final determination of eligibility. Overwhelmingly (95.8% of the time) it was the systolic blood pressure that was not under control. However, most of the patients who had not achieved target according to our criteria were within 10 mmHg of the recommended targets. Isolated systolic blood pressure was the best predictor of elevated mean daytime blood pressure on 24 hour ABPM. CONCLUSIONS: At least 35% of patients had not achieved target blood pressure levels and this is primarily due to lack of control of systolic blood pressure. The best predictor of continuing hypertension on 24 hour ABPM was the mean systolic blood pressure on the patients chart. However, only 69% of patients who were uncontrolled according blood pressures recorded in the chart were uncontrolled according to 24 hour ABPM criteria. This suggests that the white coat effect makes blood pressure measurements in the doctor's offices, at least as currently done, not sufficiently accurate for determining treatment endpoint

    Circular RNAs Could Encode Unique Proteins and Affect Cancer Pathways

    Get PDF
    CircRNAs constitute a novel class of RNA, generally considered as non-coding RNAs; nonetheless, their coding potential has been under scrutiny. In this work, we systematically explored the predicted proteins of more than 160,000 circRNAs detected by exome capture RNA-sequencing and collected in the MiOncoCirc pan-cancer compendium, including normal and cancer samples from different types of tissues. For the functional evaluation, we compared their primary structure and domain composition with those derived from the same linear mRNAs. Among the 4362 circRNAs potentially encoding proteins with a unique primary structure and 1179 encoding proteins with a novel domain composition, 183 were differentially expressed in cancer. In particular, eight were associated with prognosis in acute myeloid leukemia. The functional classification of the dysregulated circRNA-encoded polypeptides showed an enrichment in the heme and cancer signaling, DNA-binding, and phosphorylation processes, and disclosed the roles of some circRNA-based effectors in cancer

    The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension

    Get PDF
    BACKGROUND: Increasing evidence suggests that ABPM more closely predicts target organ damage than does clinic measurement. Future guidelines may suggest ABPM as routine in the diagnosis and monitoring of hypertension. This would create difficulties as this test is expensive and often difficult to obtain. The purpose of this study is to determine the degree to which the BpTRU automatic blood pressure monitor predicts results on 24 hour ambulatory blood pressure monitoring (ABPM). METHODS: A quantitative analysis comparing blood pressure measured by the BpTRU device with the mean daytime blood pressure on 24 hour ABPM. The study was conducted by the Centre for Studies in Primary Care, Queen's University, Kingston, Ontario, Canada on adult primary care patients who are enrolled in two randomized controlled trials on hypertension. The main outcomes were the mean of the blood pressures measured at the three most recent office visits, the initial measurement on the BpTRU-100, the mean of the five measurements on the BpTRU monitor, and the daytime average on 24 hour ABPM. RESULTS: The group mean of the three charted clinic measured blood pressures (150.8 (SD10.26) / 82.9 (SD 8.44)) was not statistically different from the group mean of the initial reading on BpTRU (150.0 (SD21.33) / 83.3 (SD12.00)). The group mean of the average of five BpTRU readings (140.0 (SD17.71) / 79.8 (SD 10.46)) was not statistically different from the 24 hour daytime mean on ABPM (141.5 (SD 13.25) / 79.7 (SD 7.79)). Within patients, BpTRU average correlated significantly better with daytime ambulatory pressure than did clinic averages (BpTRU r = 0.571, clinic r = 0.145). Based on assessment of sensitivity and specificity at different cut-points, it is suggested that the initial treatment target using the BpTRU be set at <135/85 mmHG, but achievement of target should be confirmed using 24 hour ABPM. CONCLUSION: The BpTRU average better predicts ABPM than does the average of the blood pressures recorded on the patient chart from the three most recent visits. The BpTRU automatic clinic blood pressure monitor should be used as an adjunct to ABPM to effectively diagnose and monitor hypertension

    Blood pressure control and treatment adherence in hypertensive patients with metabolic syndrome: protocol of a randomized controlled study based on home blood pressure telemonitoring vs. conventional management and assessment of psychological determinants of adherence (TELEBPMET Study).

    Get PDF
    BACKGROUND: Inadequate blood pressure control and poor adherence to treatment remain among the major limitations in the management of hypertensive patients, particularly of those at high risk of cardiovascular events. Preliminary evidence suggests that home blood pressure telemonitoring (HBPT) might help increasing the chance of achieving blood pressure targets and improve patient's therapeutic adherence. However, all these potential advantages of HBPT have not yet been fully investigated. METHODS/DESIGN: The purpose of this open label, parallel group, randomized, controlled study is to assess whether, in patients with high cardiovascular risk (treated or untreated essential arterial hypertension--both in the office and in ambulatory conditions over 24 h--and metabolic syndrome), long-term (48 weeks) blood pressure control is more effective when based on HBPT and on the feedback to patients by their doctor between visits, or when based exclusively on blood pressure determination during quarterly office visits (conventional management (CM)). A total of 252 patients will be enrolled and randomized to usual care (n = 84) or HBPT (n = 168). The primary study endpoint will be the rate of subjects achieving normal daytime ambulatory blood pressure targets (< 135/85 mmHg) 24 weeks and 48 weeks after randomization. In addition, the study will assess the psychological determinants of adherence and persistence to drug therapy, through specific psychological tests administered during the course of the study. Other secondary study endpoints will be related to the impact of HBPT on additional clinical and economic outcomes (number of additional medical visits, direct costs of patient management, number of antihypertensive drugs prescribed, level of cardiovascular risk, degree of target organ damage and rate of cardiovascular events, regression of the metabolic syndrome). DISCUSSION: The TELEBPMET Study will show whether HBPT is effective in improving blood pressure control and related medical and economic outcomes in hypertensive patients with metabolic syndrome. It will also provide a comprehensive understanding of the psychological determinants of medication adherence and blood pressure control of these patients

    The Hamiltonian formulation of General Relativity: myths and reality

    Full text link
    A conventional wisdom often perpetuated in the literature states that: (i) a 3+1 decomposition of space-time into space and time is synonymous with the canonical treatment and this decomposition is essential for any Hamiltonian formulation of General Relativity (GR); (ii) the canonical treatment unavoidably breaks the symmetry between space and time in GR and the resulting algebra of constraints is not the algebra of four-dimensional diffeomorphism; (iii) according to some authors this algebra allows one to derive only spatial diffeomorphism or, according to others, a specific field-dependent and non-covariant four-dimensional diffeomorphism; (iv) the analyses of Dirac [Proc. Roy. Soc. A 246 (1958) 333] and of ADM [Arnowitt, Deser and Misner, in "Gravitation: An Introduction to Current Research" (1962) 227] of the canonical structure of GR are equivalent. We provide some general reasons why these statements should be questioned. Points (i-iii) have been shown to be incorrect in [Kiriushcheva et al., Phys. Lett. A 372 (2008) 5101] and now we thoroughly re-examine all steps of the Dirac Hamiltonian formulation of GR. We show that points (i-iii) above cannot be attributed to the Dirac Hamiltonian formulation of GR. We also demonstrate that ADM and Dirac formulations are related by a transformation of phase-space variables from the metric gμνg_{\mu\nu} to lapse and shift functions and the three-metric gkmg_{km}, which is not canonical. This proves that point (iv) is incorrect. Points (i-iii) are mere consequences of using a non-canonical change of variables and are not an intrinsic property of either the Hamilton-Dirac approach to constrained systems or Einstein's theory itself.Comment: References are added and updated, Introduction is extended, Subsection 3.5 is added, 83 pages; corresponds to the published versio
    • …
    corecore