22 research outputs found
Pimobendan improves clinical signs in short term compared to digoxin or placebo in dogs with heart failure due to chronic degenerative mitral valve disease
Background: Chronic degenerative mitral valve disease (CDMVD) continues to be the most common cause of heart failure (HF) in small breed dogs. Pimobendan (PIMO) is a mixed action drug with inotropic and vasodilator properties and is widely used to treat heart disease in dogs. Therefore, PIMO increases cardiac output, reduces both preload and afterload and increases myocardial contractility without increasing energy consumption and myocardial oxygen. Digoxin (DIG) is a cardiac glycoside acting through inhibition of the sarcolemmal Na+/K+ ATPase pump, hence increasing intracellular calcium. It exerts benefi cial effects on left ventricular function, symptoms and exercise tolerance. The purpose of this prospective, randomized, double blind clinical trial was to evaluate the clinical response and QoLQ in heart failure (HF) dogs treated with digoxin or pimobendan in addition to conventional therapy (furosemide and benazepril). Materials, Methods & Results: Inclusion criteria: dogs in class III or stabilized class IV (NYHA). Exclusion criteria: use of positive inotrope and antiarrhythmic, presence of atrial fi brillation, renal or hepatic disease or neoplasia. Thirty three dogs were included and randomly assigned to DIG (n = 11), PIMO (n = 14) and placebo (PL) (n = 8) and followed up weekly. Data was evaluated for days zero, 7, 14 and 28. Increasing score was assigned to each variable depending on worsening of clinical evaluation (history and physical exam, QoLQ and echocardiogram (echo).Three dogs died during treatment due to worsening of HF, one of PL group and two of DIG group; furthermore, one of PIMO group was censored due to worsening of heart failure. There was no signifi cant difference between and within groups for echo and radiography. PL and DIG groups did not show any signifi cant difference throughout the 28 days of treatment. PIMO group showed lower physical exam score and increased early mitral infl ow velocity on day 28. Serum creatinine increased on days 14 and 28 compared to baseline, but within normal limits. The groups were similar within each evaluation day. Discussion: This is the fi rst short term prospective randomized double blind study comparing PIMO to DIG or PL additionally to conventional therapy (ACEi and furosemide) for dogs with HF due to CDMVD. It was observed an early signifi cant clinical improvement in dogs receiving PIMO compared to those receiving DIG or PL. The increase in early mitral infl ow velocity (E-wave) on day 28 for PIMO group is suggestive of diastolic dysfunction improvement, but this is only one variable related to diastolic function. Creatinine concentration increased in PIMO group, although it remained within normal range. In the present study, although all the three groups received furosemide, only PIMO group showed increase in blood creatinine between baseline and days 7 and 28. This result must be explored in later studies. Regarding the exercise intolerance assessment in a QoLQ, it must be aware that the owner evaluation is strongly infl uenced by the level of exercise that the dog is regularly submitted. Considering that most of the times, small breed dogs in a more advanced age is probably more sedentary and this fact surely precludes the owner to assess the exercise capacity. A more objective evaluation of the exercise tolerance should be considered in further clinical trials. Probably because of the small number of animals included in this study, differences in other studied variables were not found. The short-term follow-up of these patients may also have infl uenced the lack of differences among groups. Considering that stronger clinical evidence is needed to guide clinical decisions, longer prospective studies are also needed to compare the effects of DIG and PIMO, as well as to consider the benefi ts of the use or not of DIG associated with PIMO for dogs in HF due to CDMVD.Funding. This project was fi nancially supported by FAPESP - São Paulo Research Foundation, process number 08/57620-2
Tamponamento intrauterino induzido por vácuo para hemorragia pós-parto: uma revisão sistemática
A hemorragia pós-parto (HPP) é uma complicação grave e uma das principais causas de mortalidade materna global, respondendo por aproximadamente 25% de todos os óbitos maternos. A busca por intervenções eficazes e seguras é crítica para melhorar os desfechos maternos. O tamponamento intrauterino induzido por vácuo (VHD) surgiu como uma abordagem promissora, oferecendo potencial para rápido controle do sangramento e redução da necessidade de procedimentos invasivos. Nesse sentido, o presente estudo tem como objetivo analisar a eficácia, segurança e aplicabilidade na prática clínica moderna. Foi realizada uma revisão sistemática da literatura de 2016 a 2024 nas bases de dados PubMed (Medline), Cochrane Library e SciELO. A seleção dos estudos foi baseada em critérios de inclusão e exclusão rigorosos, focando na eficácia, segurança e aplicabilidade do VHD para tratamento da HPP. Três estudos chave foram analisados, com pacientes submetidos ao tratamento com VHD para HPP. Os resultados demonstraram uma taxa de sucesso no tratamento variando de 73% a 94%, com um controle do sangramento alcançado em uma média de 3 minutos. Foi observada uma redução significativa na necessidade de transfusões maciças de sangue e na perda de sangue estimada quando comparado com o tamponamento com balão uterino. Eventos adversos foram relatados, mas todos resolveram-se sem sequelas graves. O tamponamento intrauterino induzido por vácuo apresenta-se como uma opção promissora no tratamento da hemorragia pós-parto, com resultados consistentes indicando eficácia no controle do sangramento e redução na necessidade de transfusões sanguíneas. Embora os resultados sejam encorajadores, mais estudos são necessários para confirmar essas descobertas e explorar plenamente o potencial do VHD na prática clínica. O VHD emerge como uma alternativa eficaz e segura, com potencial para melhorar significativamente os desfechos maternos e reduzir a morbimortalidade associada à HPP
O perfil semiológico do paciente portador de hemorragia digestiva alta
OBJETIVO: O seguinte estudo objetivou descrever a semiologia do paciente portador de hemorragia digestiva alta, considerando como determinante na avaliação de potencias focos hemorrágicos. METODOLOGIA: Foram realizadas buscas nas plataformas do SciELO, LILACS, PubMed, Scopus e Google Scholar,utilizando os descritores gastrointestinal bleeding, peptic ulcerous disease e varicose hemorrhage, sendo identificados 35 estudos, dos quais foram incluídos 13 artigos completos. Desses estudos, 5 avaliaram as principais etiologias, 2 o surgimento de novos testes diagnósticos, 2 analisaram os aspectos epidemiológicos e 1 a sintomatologia apresentada pelo acometimento da hemorragia digestiva alta. Observou-se inicialmente a abundâncias de informações conceituais sobre o sangramento, como um transtorno clínico comum, acompanhada de inúmeras manifestações, considerando que o foco hemorrágico pode ocorrer em qualquer porção do trato gastrointestinal. Neste estudo, todas as publicações eleitas apresentaram o quadro semiológico composto por algia abdominal, indícios de choque hipovolêmico e taquicardia, alguns exibiram quedas abruptas da pressão arterial, odinofagia, êmese, náuseas e estado ictérico. Os pacientes implicados, cronicamente, já manifestaram ocorrências prévias, devido ao caráter recidivante torna-se essencial investigar a existência de varizes, fístula aorto-entérica, angiodisplasia e doença ulcerosa. CONCLUSÃO: Elucida-se que a hemorragia digestiva alta representa a principal causa de sangramento do trato gastrointestinal, majoritamente manifesta-se como hematêmese ou melena e cursam com o quadro sintomatológico que auxilia na avaliação da gravidade deste e o embasamento de potenciais focos de sangramento e que contribuam para disseminação de informações e intervenções futuras
Catálogo Taxonômico da Fauna do Brasil: setting the baseline knowledge on the animal diversity in Brazil
The limited temporal completeness and taxonomic accuracy of species lists, made available in a traditional manner in scientific publications, has always represented a problem. These lists are invariably limited to a few taxonomic groups and do not represent up-to-date knowledge of all species and classifications. In this context, the Brazilian megadiverse fauna is no exception, and the Catálogo Taxonômico da Fauna do Brasil (CTFB) (http://fauna.jbrj.gov.br/), made public in 2015, represents a database on biodiversity anchored on a list of valid and expertly recognized scientific names of animals in Brazil. The CTFB is updated in near real time by a team of more than 800 specialists. By January 1, 2024, the CTFB compiled 133,691 nominal species, with 125,138 that were considered valid. Most of the valid species were arthropods (82.3%, with more than 102,000 species) and chordates (7.69%, with over 11,000 species). These taxa were followed by a cluster composed of Mollusca (3,567 species), Platyhelminthes (2,292 species), Annelida (1,833 species), and Nematoda (1,447 species). All remaining groups had less than 1,000 species reported in Brazil, with Cnidaria (831 species), Porifera (628 species), Rotifera (606 species), and Bryozoa (520 species) representing those with more than 500 species. Analysis of the CTFB database can facilitate and direct efforts towards the discovery of new species in Brazil, but it is also fundamental in providing the best available list of valid nominal species to users, including those in science, health, conservation efforts, and any initiative involving animals. The importance of the CTFB is evidenced by the elevated number of citations in the scientific literature in diverse areas of biology, law, anthropology, education, forensic science, and veterinary science, among others
Comparative study of left ventricular measurement by bidimensional and M mode echocardiography performed in short-axis and long-axis in adult normal German Shepherds
A avaliação do ventrículo esquerdo (VE) é uma das principais contribuições da ecocardiografia no estudo da função cardíaca e inclui a mensuração dos diâmetros da cavidade e espessura das paredes em diástole e sístole. O estudo por meio do modo M tem sido usado como padrão para a realização da mensuração e para o cálculo de índices sistólicos, mas o modo bidimensional também é utilizado para este fim. As medidas podem ser adquiridas a partir de dois planos de imagem: transversal e longitudinal. A definição de intervalos de confiança para valores normais de VE permite a identificação de remodelamento ventricular, concêntrico ou excêntrico, decorrente de doenças cardiovasculares ou sistêmicas. Assim sendo, o objetivo deste estudo foi comparar as medidas ecocardiográficas desta câmara obtidas pelos seguintes métodos: modo M em corte transversal, modo M em corte longitudinal, modo bidimensional em corte transversal e modo bidimensional em corte longitudinal. Adicionalmente, estudou-se o comportamento do efeito do peso e do sexo nos métodos mencionados. Foram selecionados 40 cães adultos da raça Pastor Alemão sem alterações cardiovasculares. A realização do ecocardiograma de cada animal inclui os quatro métodos descritos acima, de acordo com o recomendado pela literatura. Foram pesquisados os efeitos do corte e do método, bem como a influência do peso e do sexo, sobre cada medida estudada, linear ou derivada. O peso apresentou correlação com todas as medidas lineares de VE em pelo menos um dos métodos, mas não com fração de encurtamento (FE) e fração de ejeção (FEj). Utilizando-se a análise univariada, verificou-se que machos apresentaram todas as medidas estudadas significativamente maiores que fêmeas em pelo menos um dos métodos, exceto FE e FEj, cujos valores não foram diferentes entre os sexos. Observou-se efeito isolado do corte apenas sobre diâmetro diastólico final do ventrículo esquerdo (DdFVE), com medidas maiores obtidas no corte transversal, e mudança de comportamento do sexo nos cortes com influência significativa do peso sobre septo interventricular em diástole (SIVd). Houve efeito isolado do modo sobre os índices de função sistólica FE e FEj, com valores maiores fornecidos pelo modo M. O peso teve efeito isolado positivo sobre parede livre de ventrículo esquerdo em diástole (PLVEd), exceto no modo M em corte transversal e (diâmetro sistólico final de ventrículo esquerdo (DsFVE). O sexo, retirada a influência do peso, teve efeito isolado apenas sobre DdFVE, com machos apresentando valores significativamente maiores que fêmeas em ambos os cortes no modo bidimensional. Os resultados Os resultados mostram que há risco de erro de interpretação quando valores normais de referência, gerados a partir de determinado método, são utilizados para a avaliação de um paciente examinado por técnica de mensuração diversa, especialmente quando se obtém resultados nos limites superior ou inferior de normalidade.Left ventricle (LV) evaluation is one of the most important contributions of echocardiography in the assessment of cardiac function. It includes measurements of internal diameter and wall thickness at end-diastole and end-sistole of this chamber. M Mode echocardiography has been widely used for measuring linear dimensions and quantifying systolic function, but bidimensional mode is also used with the same purpose. The LV measurement can be derived from transverse or longitudinal images of the heart. The establishment of normal confidence intervals of LV dimensions allows identification of concentric or excentric ventricular remodeling process secondary to cardiovascular and systemic diseases. The aim of this study was to compare LV measurements obtained from four methods: M mode in short-axis, M mode in long-axis, bidimensional mode in short-axis and bidimensional mode in long-axis view of the heart. In addition the effect of weight and gender over measures was studied in the methods mentioned above. Forty adult German Shepherds without cardiovascular diseases were selected. The echocardiogram of each animal included the four described methods, according previous referenced recommendations. The effects of axis and mode as well as weight and gender were studied for each linear or derived LV measure. Weight correlated with all linear LV measures at least in one method, but not with ejection fraction (EF) and shortening fraction (SF). All LV measures of males were greater than those of females at least in one method, except for EF and SF, which did not differ between sexes. Isolated effect of the axis was observed only for LV end diastolic diameter (LVEDD), with greater values obtained from short-axis views. The combined effect of axis, gender and weight was identified in interventricular septal end diastolic thickness. There was isolated effect of mode over EF and SF, with greater measures derived from bidimensional mode methods. Weight had isolated significant positive effect over LV enddiastole posterior wall thickness in all methods, except from M mode performed in short axis, and LV end-sistolic diameter. Gender had isolated effect only over LVEDD, males showing greater values than females in bidimensional mode in short and long axis. Professionals should be aware of the possibility of erroneous interpretation when using data obtained by a different method of that used in the patient exam as reference, mainly for the values situated in inferior and superior limits of confidence intervals
Comparative study of left ventricular measurement by bidimensional and M mode echocardiography performed in short-axis and long-axis in adult normal German Shepherds
A avaliação do ventrículo esquerdo (VE) é uma das principais contribuições da ecocardiografia no estudo da função cardíaca e inclui a mensuração dos diâmetros da cavidade e espessura das paredes em diástole e sístole. O estudo por meio do modo M tem sido usado como padrão para a realização da mensuração e para o cálculo de índices sistólicos, mas o modo bidimensional também é utilizado para este fim. As medidas podem ser adquiridas a partir de dois planos de imagem: transversal e longitudinal. A definição de intervalos de confiança para valores normais de VE permite a identificação de remodelamento ventricular, concêntrico ou excêntrico, decorrente de doenças cardiovasculares ou sistêmicas. Assim sendo, o objetivo deste estudo foi comparar as medidas ecocardiográficas desta câmara obtidas pelos seguintes métodos: modo M em corte transversal, modo M em corte longitudinal, modo bidimensional em corte transversal e modo bidimensional em corte longitudinal. Adicionalmente, estudou-se o comportamento do efeito do peso e do sexo nos métodos mencionados. Foram selecionados 40 cães adultos da raça Pastor Alemão sem alterações cardiovasculares. A realização do ecocardiograma de cada animal inclui os quatro métodos descritos acima, de acordo com o recomendado pela literatura. Foram pesquisados os efeitos do corte e do método, bem como a influência do peso e do sexo, sobre cada medida estudada, linear ou derivada. O peso apresentou correlação com todas as medidas lineares de VE em pelo menos um dos métodos, mas não com fração de encurtamento (FE) e fração de ejeção (FEj). Utilizando-se a análise univariada, verificou-se que machos apresentaram todas as medidas estudadas significativamente maiores que fêmeas em pelo menos um dos métodos, exceto FE e FEj, cujos valores não foram diferentes entre os sexos. Observou-se efeito isolado do corte apenas sobre diâmetro diastólico final do ventrículo esquerdo (DdFVE), com medidas maiores obtidas no corte transversal, e mudança de comportamento do sexo nos cortes com influência significativa do peso sobre septo interventricular em diástole (SIVd). Houve efeito isolado do modo sobre os índices de função sistólica FE e FEj, com valores maiores fornecidos pelo modo M. O peso teve efeito isolado positivo sobre parede livre de ventrículo esquerdo em diástole (PLVEd), exceto no modo M em corte transversal e (diâmetro sistólico final de ventrículo esquerdo (DsFVE). O sexo, retirada a influência do peso, teve efeito isolado apenas sobre DdFVE, com machos apresentando valores significativamente maiores que fêmeas em ambos os cortes no modo bidimensional. Os resultados Os resultados mostram que há risco de erro de interpretação quando valores normais de referência, gerados a partir de determinado método, são utilizados para a avaliação de um paciente examinado por técnica de mensuração diversa, especialmente quando se obtém resultados nos limites superior ou inferior de normalidade.Left ventricle (LV) evaluation is one of the most important contributions of echocardiography in the assessment of cardiac function. It includes measurements of internal diameter and wall thickness at end-diastole and end-sistole of this chamber. M Mode echocardiography has been widely used for measuring linear dimensions and quantifying systolic function, but bidimensional mode is also used with the same purpose. The LV measurement can be derived from transverse or longitudinal images of the heart. The establishment of normal confidence intervals of LV dimensions allows identification of concentric or excentric ventricular remodeling process secondary to cardiovascular and systemic diseases. The aim of this study was to compare LV measurements obtained from four methods: M mode in short-axis, M mode in long-axis, bidimensional mode in short-axis and bidimensional mode in long-axis view of the heart. In addition the effect of weight and gender over measures was studied in the methods mentioned above. Forty adult German Shepherds without cardiovascular diseases were selected. The echocardiogram of each animal included the four described methods, according previous referenced recommendations. The effects of axis and mode as well as weight and gender were studied for each linear or derived LV measure. Weight correlated with all linear LV measures at least in one method, but not with ejection fraction (EF) and shortening fraction (SF). All LV measures of males were greater than those of females at least in one method, except for EF and SF, which did not differ between sexes. Isolated effect of the axis was observed only for LV end diastolic diameter (LVEDD), with greater values obtained from short-axis views. The combined effect of axis, gender and weight was identified in interventricular septal end diastolic thickness. There was isolated effect of mode over EF and SF, with greater measures derived from bidimensional mode methods. Weight had isolated significant positive effect over LV enddiastole posterior wall thickness in all methods, except from M mode performed in short axis, and LV end-sistolic diameter. Gender had isolated effect only over LVEDD, males showing greater values than females in bidimensional mode in short and long axis. Professionals should be aware of the possibility of erroneous interpretation when using data obtained by a different method of that used in the patient exam as reference, mainly for the values situated in inferior and superior limits of confidence intervals
Comparative study of 4 echocardiographic methods of left ventricular measurement in German Shepherd dogs
Objectives: To compare dimensions and shortening fraction (SF) of the left ventricle (LV) obtained from two-dimensional (2D) and M-mode imaging of short and long-axis views. Animals: 40 healthy, adult German Shepherd dogs. Methods: Left ventricular measurements were obtained using 4 echocardiographic methods: M-mode in short and long-axis and 2D imaging in short and long-axis. The methods were compared by studying the effects of imaging mode and axis on LV parameters, taking into account the influence of weight and gender. Results: Mean LV end-diastolic diameter was greater in short-axis views. However, this difference was not considered clinically relevant. Mean SF was higher when derived from 2D measurements with poor agreement among methods. A combined influence of axis, gender, and weight was observed on interventricular septal thickness in end diastole with poor agreement among methods. Conclusions: Some LV parameters were significantly affected by mode and axis, either in isolation or in combination with weight and gender, although the differences observed were not always clinically relevant. These findings show that using the different echocardiographic methods interchangeably to assess LV dimensions should be done with caution
Standardization of electrocardiographic parameters in healthy Golden Retrievers dogs
A distrofia muscular de Duchenne (DMD) em humanos é uma alteração neuromuscular hereditária, de caráter recessivo, ligada ao cromossomo X e causada pela ausência ou disfunção da distrofina. Clinicamente, caracteriza-se por grave alteração na musculatura esquelética, resultando em morte precoce do indivíduo acometido. Em cães da raça Golden Retriever, a mutação que leva à distrofia muscular ocorre espontaneamente e a extensa homologia entre a patogênese da DMD e da distrofia muscular do Golden Retriever permite qualificar o cão como o principal substituto de humanos nos testes clínicos de novas terapias. O miocárdio deficiente em distrofina é mais vulnerável à sobrecarga de pressão e os pacientes com DMD podem desenvolver cardiomiopatia dilatada, hipertensão arterial e o eletrocardiograma pode se apresentar distintamente anormal. No presente estudo, foram avaliados exames eletrocardiográficos de 38 cães da raça Golden Retriever clinicamente sadios (20 animais de até 12 meses de idade e 18 animais entre 12 e 36 meses de idade), com a finalidade de se obter parâmetros para a padronização do eletrocardiograma nessa referida raça, o que futuramente poderá servir de referência na identificação de cães portadores ou afetados pela distrofia muscular. Os valores eletrocardiográficos obtidos encontraram-se dentro dos valores de normalidade e referência para as diferentes raças de cães; e as variáveis peso e idade alteraram significativamente a freqüência cardíaca e a amplitude do complexo QRSThe Duchenne's muscular dystrophy (DMD) in humans is a X-linked neuromuscular disease, of recessive character, caused either by the absence or dysfunction of the dystrophin. Clinically, it is characterized by severe alteration in the skeletal musculature, resulting in precocious death. In Golden Retriever dogs, the mutation that takes to the muscular dystrophy happens spontaneously and the extensive homology among the pathogenesis of DMD and of Golden Retriever muscular dystrophy allows to qualify the dog as the main substitute of humans in the clinical tests of new therapies. The deficient myocardium in distrofin is more vulnerable to the pressure overload and the patients with DMD can develop dilated cardiomyopathy, arterial hypertension and the electrocardiogram can come distinctly abnormal. In the present study, 38 healthy Golden Retriever dogs were evaluated by electrocardiographic exam with the purpose to obtain parameters for the standardization of the electrocardiogram in the referred breed, what hereafter can serve as reference in the identification of bearer or affected dogs. Electrocardiographic values obtained were within normal values and reference for the various breeds of dogs, and the variables weight and age significantly altered heart rate and amplitude of the QRS complexFAPESP (Proc. 04/08173-2