188 research outputs found

    Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study

    Get PDF
    Background Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. Methods In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. Results The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Conclusions Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complication

    Ultrasound-guided paravertebral puncture and placement of catheters in human cadavers: an imaging study

    Get PDF
    Background During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. Methods We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. Results The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. Conclusions We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural space

    Ultrasound-guided percutaneous tracheal puncture: a computer-tomographic controlled study in cadavers

    Get PDF
    Background Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. Methods The trachea of nine cadavers was punctured using an in-plane approach with a longitudinal ultrasound visualization of the trachea. As soon as a loss of resistance was felt, or air/fluid could be aspirated into the attached syringe, the syringe was disconnected and the ultrasound transducer set aside. Thereafter, a cricothyroidotomy guidewire was inserted through the needle into the trachea. The needle was then removed, leaving the wire in place and a control CT imaging of the neck and the chest was performed. Primary outcome was successful wire insertion into the trachea. Results Tracheal puncture and wire insertion was successful in eight of nine cadavers at the first attempt and in one at the second attempt (total of 10 puncture attempts, nine successful). In eight of nine successfully inserted wires, the wire was placed on the defined midline. Conclusions Ultrasound guidance can facilitate successful tracheal puncture. However, combining an in-plane approach with a longitudinal ultrasound visualization of the trachea neither guarantees an exact midline puncture nor allows detection of a misplaced guidewir

    Ultrasound-guided thoracic paravertebral puncture and placement of catheters in human cadavers: where do catheters go?†

    Get PDF
    Background Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position. Methods In 10 cadavers, we conducted 26 ultrasound-guided paravertebral approaches combined with loss of resistance (LOR) and after an interim analysis performed 36 novel, pure ultrasound-guided (PUSG) paravertebral approaches. Needle-tip position was controlled by a first computed tomography (CT) scan. After placement of the catheters, the tips were assessed by a second CT and the spread of injected contrast dye was assessed by further CT scans. The part of the PVS near the intervertebral foramen was defined as the primary target to reach. Results The first CT scans assessing 62 needle tips revealed that: 13 (50%) of LOR and 34 (94%) of PUSG approaches were at the target; and two (8%) LOR and no PUSG approaches were outside the PVS. With the second CT scans 60 catheter-tip positions were analysed: three (12%) of LOR and five (14%) of PUSG approaches were at the target, three (12%) of LOR and two (6%) of PUSG approaches were outside the PVS. No catheters were detected in the epidural space. In two cases, insertion of the catheter was not possible. In cases with major epidural contrast, the widest contrast dye spread was 7.7 (3.5) [mean (sd)] vertebral segments. Conclusions Our new PUSG technique has a high success rate for paravertebral needle placement. Although needles were correctly positioned, catheters were usually found distant from the needle-tip positio

    Sonoelastography of the Common Flexor Tendon of the Elbow with Histologic Agreement: A Cadaveric Study.

    Get PDF
    Purpose To determine the correlation of the results of conventional B-mode ultrasonography (US) and compression sonoelastography with histologic results in common flexor tendons of the elbow in human cadavers. Materials and Methods Twenty-five common flexor tendons were evaluated in 16 fresh, unembalmed cadavers of 11 women with a median age of 85 years (range, 71-101 years) and five men with a median age of 78 years (range, 70-88 years). Informed consent was provided according to the last will of the donors. B-mode US results were classified as grade 1, normal tendon with homogeneous fibrillar pattern; grade 2, tendon thickening or hypoechoic areas and/or calcifications in less than 30% of the tendon; or grade 3, hypoechoic areas and/or calcifications greater than 30% of the tendon. Sonoelastographic results were grade 1, blue (hardest) to green (hard); grade 2, yellow (soft); and grade 3, red (softest). The intraclass correlation coefficient was calculated to determine agreement with histologic findings for each B-mode US, sonoelastographic, and combined B-mode US and sonoelastographic examination. Histologic results were grade 1, normal, with parallel fibrillar pattern; grade 2, mild tendinopathy, with cellular infiltration, angiogenesis, or fatty vacuoles; or grade 3, severe tendinopathy, with loss of parallel collagen structure and necrosis. Results Histologic alterations were detected in 44% (11 of 25) of biopsy specimens. Intraclass correlation with histologic results was 0.57 for B-mode US, 0.68 for sonoelastography, and 0.84 for the combination of the two approaches. Conclusion The addition of sonoelastography to B-mode US provided statistically significant improvement in correlation with histologic results compared with the use of B-mode US alone (P \u3c .02). (©) RSNA, 2016 Online supplemental material is available for this article

    Proteomic Analysis Identifies NDUFS1 and ATP5O as Novel Markers for Survival Outcome in Prostate Cancer

    Get PDF
    Simple Summary Due to the heterogeneity of prostate cancer (PCa), it is still difficult to provide risk stratification. Metabolic changes in PCa tissue have been described during tumor progression at genetic and transcriptomic level, but these have not yet clearly contributed to improved diagnosis and therapy. The aim of our study was to identify novel markers for aggressive prostate cancer in a proteomics-derived dataset by immunohistochemical analysis and correlation with transcriptomic data. Here, we provide potential new markers-NDUFS1 and ATP5O-for risk stratification in PCa. Additionally, we reveal for the first time a concordant increase of NDUFS1/ATP5O of mRNA expression in transcriptomic datasets and at protein level. We aimed to identify novel markers for aggressive prostate cancer in a STAT3-low proteomics-derived dataset of mitochondrial proteins by immunohistochemical analysis and correlation with transcriptomic data and biochemical recurrence in a STAT3 independent PCa cohort. Formalin-fixed paraffin-embedded tissue (FFPE) sample selection for proteomic analysis and tissue-microarray (TMA) generation was conducted from a cohort of PCa patients. Retrospective data analysis was performed with the same cohort. 153 proteins differentially expressed between STAT3-low and STAT3-high samples were identified. Out of these, 46 proteins were associated with mitochondrial processes including oxidative phosphorylation (OXPHOS), and 45 proteins were upregulated, including NDUFS1/ATP5O. In a STAT3 independent PCa cohort, high expression of NDUFS1/ATP5O was confirmed by immunocytochemistry (IHC) and was significantly associated with earlier biochemical recurrence (BCR). mRNA expression levels for these two genes were significantly higher in intra-epithelial neoplasia and in PCa compared to benign prostate glands. NDUFS1/ATP5O levels are increased both at the mRNA and protein level in aggressive PCa. Our results provide evidence that NDUFS1/ATP5O could be used to identify high-risk PCa patients

    Ultrasound-guided paravertebral puncture and placement of catheters in human cadavers: an imaging study

    Get PDF
    BACKGROUND: During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. METHODS: We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. RESULTS: The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. CONCLUSIONS: We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural spaces

    JAK-STAT inhibition impairs K-RAS-driven lung adenocarcinoma progression

    Get PDF
    Oncogenic KRAS has been difficult to target and currently there is no KRASbased targeted therapy available for patients suffering from KRASdriven lung adenocarcinoma (AC). Alternatively, targeting KRASdownstream effectors, KRAScooperating signaling pathways or cancer hallmarks, such as tumorpromoting inflammation, has been shown to be a promising therapeutic strategy. Since the JAKSTAT pathway is considered to be a central player in inflammationmediated tumorigenesis, we investigated here the implication of JAKSTAT signaling and the therapeutic potential of JAK1/2 inhibition in KRASdriven lung AC. Our data showed that JAK1 and JAK2 are activated in human lung AC and that increased activation of JAKSTAT signaling correlated with disease progression and KRAS activity in human lung AC. Accordingly, administration of the JAK1/2 selective tyrosine kinase inhibitor ruxolitinib reduced proliferation of tumor cells and effectively reduced tumor progression in immunodeficient and immunocompetent mouse models of KRASdriven lung AC. Notably, JAK1/2 inhibition led to the establishment of an antitumorigenic tumor microenvironment, characterized by decreased levels of tumorpromoting chemokines and cytokines and reduced numbers of infiltrating myeloid derived suppressor cells, thereby impairing tumor growth. Taken together, we identified JAK1/2 inhibition as promising therapy for KRASdriven lung AC.(VLID)510233

    ABCC1 and Glutathione Metabolism Limit the Efficacy of Bcl-2 Inhibitors in Acute Myeloid Leukemia

    Get PDF
    The BCL-2 inhibitor Venetoclax is a promising agent for the treatment of acute myeloid leukemia (AML). However, many patients are refractory to Venetoclax, and resistance develops quickly. ATP-binding cassette (ABC) transporters mediate chemotherapy resistance but their role in modulating the activity of targeted small-molecule inhibitors is unclear. Using CRISPR/Cas9 screening, we find that loss of ABCC1 strongly increases the sensitivity of AML cells to Venetoclax. Genetic and pharmacologic ABCC1 inactivation potentiates the anti-leukemic effects of BCL-2 inhibitors and efficiently re-sensitizes Venetoclax-resistant leukemia cells. Conversely, ABCC1 overexpression induces resistance to BCL-2 inhibitors by reducing intracellular drug levels, and high ABCC1 levels predicts poor response to Venetoclax therapy in patients. Consistent with ABCC1-specific export of glutathionylated substrates, inhibition of glutathione metabolism increases the potency of BCL-2 inhibitors. These results identify ABCC1 and glutathione metabolism as mechanisms limiting efficacy of BCL-2 inhibitors, which may pave the way to development of more effective therapies
    • …
    corecore