    The ARX and ARMAX models for thermoelectric cooling on glass windows: a comparative study

    Get PDF
    Thermoelectric cooling (TEC), in particular, can be combined with a heat sink for local cooling, but they can also be integrated into electronic chips for point-to-point cooling. The study aims to develop a dynamic model of a cooling system integrated with TEC for glass window. The main target of this study is to develop a dynamic model of a cooling system integrated with TEC. The black box modelling approach in producing a mathematical model was selected based on the ARMAX and ARX model that corresponds to the actual dynamic state of the cooling system. The best model was finalized based on the best match on curve patterns when comparing the real and estimated models using the system identification tools in MATLAB, and also having the least error. The accuracy of the models was compared and analysed. The results showed that the 4th order of the ARMAX model produced a higher best fitting and standard deviation values of 80.23% and 0.027592 compared to the 4th order of the ARX model of 78.14% and 0.030769 respectively. This system accuracy is almost within the acceptable range for most error calculations in the validation method. Yet, this cooling system integrated with TEC is found more suitable for the 4th order of the ARMAX model when compared to the ARX model due to the noise parameter in the ARMAX model. Nevertheless, the noise order in this system is not dominant, therefore, whenever the noise order of the system in the ARMAX model is high than the second structure (nb), the number of errors is also high. In addition, the ARMAX model is found incapable of achieving the highest fitting due to the losses from the dynamic environment and losses from the TEC itself. Still, the use of this black box model used in this study is a significant variation where system parameters can be identified even offline

    IDENTIFICATION OF ARX MODEL FOR THERMOELECTRIC COOLING ON GLASS WINDOWS

    Get PDF
    Thermoelectric cooling (TEC) is a solid-state heat pump that uses the Peltier effect to dissipate the heat generated by the electronic packaging system. TECs are widely used in aerospace, military, scientific work and industry due to small size, lack of moving parts, and ease of integration. In this study, a cooling system integrated with TEC is developed in a testing area (lecturer’s office) with the aim to reduce the temperature of the hot glass window area due to solar radiation that passes through it. This cooling system used direct TEC, for keeping the cooling temperature on the window to about 26 °C which is equivalent to an air conditioning setting temperature of 26 °C set during the experiment. This work includes experimental and modelling studies conducted on cooling systems integrated with TEC. The main target of this study is to develop a dynamic model of a cooling system integrated with TEC. The black box modelling approach in producing a mathematical model was selected based on the ARX model that corresponds to the actual dynamic state of the cooling system. The best model was finalized based on the best match on curve patterns when comparing the real and estimated models using the system identification tools in MATLAB, and also had the least error. The accuracy of the models was compared and analysed. The results showed that the 4th order of the ARX model produced a higher best fitting and standard deviation values of 78.14% and 0.030769. This system accuracy is almost within the acceptable range for most error calculations in the validation method. In addition, the ARX model is found incapable of achieving the highest fitting due to the losses from the dynamic environment and losses from the TEC itself. Still, the use of this black box model used in this study is a significant variation where system parameters can be identified even offline

    Thermal energy storage (TES) technology for active and passive cooling in buildings: A Review

    No full text
    Thermal energy storage (TES) system is one of the outstanding technologies available contributes for achieving sustainable energy demand. The energy storage system has been proven capable of narrowing down the energy mismatch between energy supply and demand. The thermal energy storage (TES) - buildings integration is expected to minimize the energy demand shortage and also offers for better energy management in building sector. This paper presents a state of art of the active and passive TES technologies integrated in the building sector. The integration method, advantages and disadvantages of both techniques were discussed. The TES for low energy building is inevitably needed. This study prescribes that the integration of TES system for both active and passive cooling techniques are proven to be beneficial towards a better energy management in buildings

    Cooling Performance of Thermoelectric Cooling (TEC) and Applications: A review

    No full text
    Thermoelectric cooling (TEC) is a new attractive method that is can be used as a temperature controller. Thermoelectric module (TEM) is a device that environmentally friendly utilizing for cooling and heating application such as heat pump and power generation. Therefore, the understanding of relation between electrical conductivity and heat conductivity of the TEC material is essentially to improve the coefficient of performance (COP) efficiency. The figure of merit is addressed by focusing the best material in TEC with different cooling material. The critical finding of TEC for this review paper is the higher the electrical conductivity and the lower thermal conductivity, the maximum the COP. Finally, the possiblity of the TEC application is reviewed according to the advantages of TEC such as high reliability, less maintenance and compact size that commercially found in large range of thermoelectric cooling system.

    Cooling Performance of Thermoelectric Cooling (TEC) and Applications: A review

    No full text
    Thermoelectric cooling (TEC) is a new attractive method that is can be used as a temperature controller. Thermoelectric module (TEM) is a device that environmentally friendly utilizing for cooling and heating application such as heat pump and power generation. Therefore, the understanding of relation between electrical conductivity and heat conductivity of the TEC material is essentially to improve the coefficient of performance (COP) efficiency. The figure of merit is addressed by focusing the best material in TEC with different cooling material. The critical finding of TEC for this review paper is the higher the electrical conductivity and the lower thermal conductivity, the maximum the COP. Finally, the possiblity of the TEC application is reviewed according to the advantages of TEC such as high reliability, less maintenance and compact size that commercially found in large range of thermoelectric cooling system.

    A review on the methods to mitigate the challenges in photovoltaic system

    No full text
    The quantity of electricity produced from the photovoltaic (PV) system is depends on the PV panel’s performance itself. Recently, the challenges in the PV system have been greatly discussed by researchers and environmentalists. The non-uniform PV output power, partial shading conditions and high operating temperature of PV cells are the challenges that always known to reduce the PV system’s performance. This paper provides a literature review on the challenges and methods to mitigate the challenges. The future works involving of modelling and computational techniques also has been proposed to overcome the problems, hence, enhancing the PV system’s performance