12 research outputs found
Autonomic reactions and peri-interventional alterations in body weight as potential supplementary outcome parameters for thromboembolic stroke in rats
BACKGROUND: Since several neuroprotectives failed to reproduce promising preclinical results under clinical conditions, efforts emerged to implement clinically relevant endpoints in animal stroke studies. Thereby, insufficient attention was given on autonomic reactions due to experimental stroke, although clinical trials reported on high functional and prognostic impact. This study focused on autonomic consequences and body weight changes in a translational relevant stroke model and investigated interrelations to different outcome measurements. METHODS: Forty-eight rats underwent thromboembolic middle cerebral artery occlusion (MCAO) while recording heart rate (HR) and mean arterial pressure (MAP). After assessing early functional impairment (Menzies score), animals were assigned to control procedure or potentially neuroprotective treatment with normobaric (NBO) or hyperbaric oxygen (HBO). Four or 24 hours after ischemia onset, functional impairment was re-assessed and FITC-albumin administered intravenously obtaining leakage-related blood–brain barrier (BBB) impairment. Body weight was documented prior to MCAO and 4 or 24 hours after ischemia onset. RESULTS: During MCAO, HR was found to increase significantly while MAP decreased. The amount of changes in HR was positively correlated with early functional impairment (P = 0.001): Severely affected animals provided an increase of 15.2 compared to 0.8 beats/minute in rats with low impairment (P = 0.048). Regarding body weight, a decrease of 9.4% within 24 hours after MCAO occurred, but treatment-specific alterations showed no significant correlations with respective functional or BBB impairment. CONCLUSIONS: Future studies should routinely include autonomic parameters to allow inter-group comparisons and better understanding of autonomic reactions due to experimental stroke. Prospectively, autonomic consequences might represent a useful outcome parameter enhancing the methodological spectrum of preclinical stroke studies
Cmr1/WDR76 defines a nuclear genotoxic stress body linking genome integrity and protein quality control
DNA replication stress is a source of genomic instability. Here we identify ​changed mutation rate 1 (​Cmr1) as a factor involved in the response to DNA replication stress in Saccharomyces cerevisiae and show that ​Cmr1—together with ​Mrc1/​Claspin, ​Pph3, the chaperonin containing ​TCP1 (CCT) and 25 other proteins—define a novel intranuclear quality control compartment (INQ) that sequesters misfolded, ubiquitylated and sumoylated proteins in response to genotoxic stress. The diversity of proteins that localize to INQ indicates that other biological processes such as cell cycle progression, chromatin and mitotic spindle organization may also be regulated through INQ. Similar to ​Cmr1, its human orthologue ​WDR76 responds to proteasome inhibition and DNA damage by relocalizing to nuclear foci and physically associating with CCT, suggesting an evolutionarily conserved biological function. We propose that ​Cmr1/​WDR76 plays a role in the recovery from genotoxic stress through regulation of the turnover of sumoylated and phosphorylated proteins
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray
spectrometer, studied since 2015 for flying in the mid-30s on the Athena space
X-ray Observatory, a versatile observatory designed to address the Hot and
Energetic Universe science theme, selected in November 2013 by the Survey
Science Committee. Based on a large format array of Transition Edge Sensors
(TES), it aims to provide spatially resolved X-ray spectroscopy, with a
spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of
5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement
Review (SRR) in June 2022, at about the same time when ESA called for an
overall X-IFU redesign (including the X-IFU cryostat and the cooling chain),
due to an unanticipated cost overrun of Athena. In this paper, after
illustrating the breakthrough capabilities of the X-IFU, we describe the
instrument as presented at its SRR, browsing through all the subsystems and
associated requirements. We then show the instrument budgets, with a particular
emphasis on the anticipated budgets of some of its key performance parameters.
Finally we briefly discuss on the ongoing key technology demonstration
activities, the calibration and the activities foreseen in the X-IFU Instrument
Science Center, and touch on communication and outreach activities, the
consortium organisation, and finally on the life cycle assessment of X-IFU
aiming at minimising the environmental footprint, associated with the
development of the instrument. Thanks to the studies conducted so far on X-IFU,
it is expected that along the design-to-cost exercise requested by ESA, the
X-IFU will maintain flagship capabilities in spatially resolved high resolution
X-ray spectroscopy, enabling most of the original X-IFU related scientific
objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental
Astronomy with minor editin
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
48 pages, 29 figures, submitted for publication in Experimental AstronomyThe Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. It is expected that thanks to the studies conducted so far on X-IFU, along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained (abridged)