5 research outputs found

    Clinically applicable artificial intelligence system for dental diagnosis with CBCT

    Get PDF
    Abstract In this study, a novel AI system based on deep learning methods was evaluated to determine its real-time performance of CBCT imaging diagnosis of anatomical landmarks, pathologies, clinical effectiveness, and safety when used by dentists in a clinical setting. The system consists of 5 modules: ROI-localization-module (segmentation of teeth and jaws), tooth-localization and numeration-module, periodontitis-module, caries-localization-module, and periapical-lesion-localization-module. These modules use CNN based on state-of-the-art architectures. In total, 1346 CBCT scans were used to train the modules. After annotation and model development, the AI system was tested for diagnostic capabilities of the Diagnocat AI system. 24 dentists participated in the clinical evaluation of the system. 30 CBCT scans were examined by two groups of dentists, where one group was aided by Diagnocat and the other was unaided. The results for the overall sensitivity and specificity for aided and unaided groups were calculated as an aggregate of all conditions. The sensitivity values for aided and unaided groups were 0.8537 and 0.7672 while specificity was 0.9672 and 0.9616 respectively. There was a statistically significant difference between the groups (p = 0.032). This study showed that the proposed AI system significantly improved the diagnostic capabilities of dentists

    AI-based automatic segmentation of craniomaxillofacial anatomy from CBCT scans for automatic detection of pharyngeal airway evaluations in OSA patients

    No full text
    Abstract This study aims to generate and also validate an automatic detection algorithm for pharyngeal airway on CBCT data using an AI software (Diagnocat) which will procure a measurement method. The second aim is to validate the newly developed artificial intelligence system in comparison to commercially available software for 3D CBCT evaluation. A Convolutional Neural Network-based machine learning algorithm was used for the segmentation of the pharyngeal airways in OSA and non-OSA patients. Radiologists used semi-automatic software to manually determine the airway and their measurements were compared with the AI. OSA patients were classified as minimal, mild, moderate, and severe groups, and the mean airway volumes of the groups were compared. The narrowest points of the airway (mm), the field of the airway (mm2), and volume of the airway (cc) of both OSA and non-OSA patients were also compared. There was no statistically significant difference between the manual technique and Diagnocat measurements in all groups (p > 0.05). Inter-class correlation coefficients were 0.954 for manual and automatic segmentation, 0.956 for Diagnocat and automatic segmentation, 0.972 for Diagnocat and manual segmentation. Although there was no statistically significant difference in total airway volume measurements between the manual measurements, automatic measurements, and DC measurements in non-OSA and OSA patients, we evaluated the output images to understand why the mean value for the total airway was higher in DC measurement. It was seen that the DC algorithm also measures the epiglottis volume and the posterior nasal aperture volume due to the low soft-tissue contrast in CBCT images and that leads to higher values in airway volume measurement

    Evaluation of a Decision Support System Developed with Deep Learning Approach for Detecting Dental Caries with Cone-Beam Computed Tomography Imaging

    No full text
    This study aims to investigate the effect of using an artificial intelligence (AI) system (Diagnocat, Inc., San Francisco, CA, USA) for caries detection by comparing cone-beam computed tomography (CBCT) evaluation results with and without the software. 500 CBCT volumes are scored by three dentomaxillofacial radiologists for the presence of caries separately on a five-point confidence scale without and with the aid of the AI system. After visual evaluation, the deep convolutional neural network (CNN) model generated a radiological report and observers scored again using AI interface. The ground truth was determined by a hybrid approach. Intra- and inter-observer agreements are evaluated with sensitivity, specificity, accuracy, and kappa statistics. A total of 6008 surfaces are determined as ‘presence of caries’ and 13,928 surfaces are determined as ‘absence of caries’ for ground truth. The area under the ROC curve of observer 1, 2, and 3 are found to be 0.855/0.920, 0.863/0.917, and 0.747/0.903, respectively (unaided/aided). Fleiss Kappa coefficients are changed from 0.325 to 0.468, and the best accuracy (0.939) is achieved with the aided results. The radiographic evaluations performed with aid of the AI system are found to be more compatible and accurate than unaided evaluations in the detection of dental caries with CBCT images