192,718 research outputs found
Measurements of Absolute Hadronic Branching Fractions of D Mesons
Using e+e- collisions recorded at the psi(3770) resonance with the CLEO-c
detector at the Cornell Electron Storage Ring, we determine absolute hadronic
branching fractions of charged and neutral D mesons. Among measurements for
both Cabibbo-favored and Cabibbo-suppressed modes, we obtain reference
branching fractions B(D0 -> K-pi+)=(3.91 +- 0.08 +- 0.09)% and B(D+ ->
K-pi+pi+)=(9.5 +- 0.2 +- 0.3)%, where the uncertainties are statistical and
systematic, respectively. Using a determination of the integrated luminosity,
we also extract the e+e- -> DDbar cross sections.Comment: 3 pages, to appear in the Proceedings of PANIC'05 (Particles and
Nuclei International Conference), Santa Fe, NM, October 24-28 200
Oscillation-Based Test Structure and Method for OTA-C Filters
“This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder." “Copyright IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.”This paper describes a design for testability technique for operational transconductance amplifier and capacitor filters using an oscillation-based test topology. The oscillation-based test structure is a vectorless output test strategy easily extendable to built-in self-test. The proposed methodology converts filter under test into a quadrature oscillator using very simple techniques and measures the output frequency. The oscillation frequency may be considered as a digital signal and it can be evaluated using digital circuitry therefore the test time is very small. These characteristics imply that the proposed method is very suitable for catastrophic and parametric faults testing and also effective in detecting single and multiple faults. The validity of the proposed method has been verified using comparison between faulty and fault-free simulation results of two integrator loop and Tow-Thomas filters. Simulation results in 0.25 mum CMOS technology show that the proposed oscillation-based test strategy for OTA-C filters has 87% fault coverage and with a minimum number of extra components, requires a negligible area overhead
Oscillation-based Test Method for Continuous-time OTA-C Filters
“This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder." “Copyright IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.”Design for testability technique using oscillation-based test topology for KHN OTA-C filters is proposed. The oscillation-based test structure is a vectorless output test strategy easily extendable to built-in self-test. During test mode, the filter under test is converted into an oscillator by establishing the oscillation condition in its transfer function. The oscillator frequency can be measured using digital circuitry and deviations from the cut-off frequency indicate the faulty behaviour of the filter. The proposed method is suitable for both catastrophic and parametric fault diagnosis as well as effective in detecting single and multiple faults. The validity of the proposed method has been verified using comparison between faulty and fault-free simulation results of KHN OTA-C filter. Simulation results in 0.25mum CMOS technology show that the proposed oscillation-based test strategy has 84% fault coverage and with a minimum number of extra components, requires a negligible area overhead.Final Published versio
High-Order Adiabatic Approximation for Non-Hermitian Quantum System and Complexization of Berry's Phase
In this paper the evolution of a quantum system drived by a non-Hermitian
Hamiltonian depending on slowly-changing parameters is studied by building an
universal high-order adiabatic approximation(HOAA) method with Berry's phase
,which is valid for either the Hermitian or the non-Hermitian cases. This
method can be regarded as a non-trivial generalization of the HOAA method for
closed quantum system presented by this author before. In a general situation,
the probabilities of adiabatic decay and non-adiabatic transitions are
explicitly obtained for the evolution of the non-Hermitian quantum system. It
is also shown that the non-Hermitian analog of the Berry's phase factor for the
non-Hermitian case just enjoys the holonomy structure of the dual linear bundle
over the parameter manifold. The non-Hermitian evolution of the generalized
forced harmonic oscillator is discussed as an illustrative examples.Comment: ITP.SB-93-22,17 page
An quantum approach of measurement based on the Zurek's triple model
In a close form without referring the time-dependent Hamiltonian to the total
system, a consistent approach for quantum measurement is proposed based on
Zurek's triple model of quantum decoherence [W.Zurek, Phys. Rev. D 24, 1516
(1981)]. An exactly-solvable model based on the intracavity system is dealt
with in details to demonstrate the central idea in our approach: by peeling off
one collective variable of the measuring apparatus from its many degrees of
freedom, as the pointer of the apparatus, the collective variable de-couples
with the internal environment formed by the effective internal variables, but
still interacts with the measured system to form a triple entanglement among
the measured system, the pointer and the internal environment. As another
mechanism to cause decoherence, the uncertainty of relative phase and its
many-particle amplification can be summed up to an ideal entanglement or an
Shmidt decomposition with respect to the preferred basis.Comment: 22pages,3figure
- …